Solman Si CA 230 multi-component flue gas analyzer from France
Solman Si CA 230 multi-component flue gas analyzer from France

Solman Si CA 230 multi-component flue gas analyzer from France

Category:

Instrumentation/Gas analyzer/flue gas analyzer

Model:

Si-CA 130

Brand:

Thermal Holding Environmental Protection

model:

Si-CA 130

resolution:

one

measurement object:

flue gas

measurement range:

five hundred

power supply voltage:

two hundred and twenty

type:

eleven

display mode:

one

structural style :

one

Processing & Customization:

No

gas flow rate:

one thousand

manufacturer:

Solman

Retail Price

45,000.00USD


重量

kg

  • Product Description
  • model

    Si-CA 130

    resolution

    one

    measurement object

    flue gas

    measurement range

    five hundred

    power supply voltage

    two hundred and twenty

    type

    eleven

    display mode

    one

    structural style

    one

    Processing & Customization

    No

    gas flow rate

    one thousand

    manufacturer

    Solman

    Description :

      Solman Si CA 230 multi-component flue gas analyzer from France

      1 Si-CA 130 product description is suitable for monitoring the composition and efficiency of post combustion flue gas in boilers, internal combustion engines, and other combustion equipment. It has 2-6 replaceable gas sensors and its main features are as follows:

      Alternative gas sensors include: O2, CO, NO, Low NO, NO2, Low NO2, SO2, H2S, CxHy (HC), Low SO2? CO automatic dilution and protection range: 50000 ppm? NOx and Low NOx? High definition color touch screen display? Pre calibrated sensors that can be replaced on-site

      Can the host memory record 2000 sets of data? It can connect to a smartphone app through wireless functionality to generate reports and automatically/manually record and analyze data.

      Si-CA 230 equipped with: 300 * mm probe, temperature resistance up to+800 ° C; 3m double hose cable; ABS hard plastic portable case, anti slip rubber protective cover for the host, condensate sink (with filter), charger, USB data cable, quick start guide and factory calibration certificate (* long probe available)

      This smoke analyzer is used for parameter measurement of combustion equipment emission systems and cannot be used or used as an alarm system

      7 1. two Probe handle positioning cone (adjustable) 3 four Smoke probe high-definition color touch display screen 5 On/Off button 1 Min DIN interface, used to connect CO and CO2 environmental probes

      2. Thermocouple interface (ambient temperature probe) 3 Thermocouple interface (flue gas temperature probe) 4 Negative end pressure port (P -) 5. Positive end pressure port (P+)

      6. Gas interface (connected to condensate tank)

      7. Introduction to USB TypeC Connection Port Products

      7 2.2 ? The main function of the screen is a high-definition backlit color touch screen,

      4.3 inches, screen resolution: 480 x 272 pixels, making it easier for operators to view measurement data.

      The screen has a zoom function, which allows you to zoom in/out to view measurement data. The host is equipped with a rechargeable battery with an input power of 5V/2A. The icon in the upper right corner of the screen displays the power level. To ensure that the battery is fully charged, please ensure that the charging time is at least 6.5 hours.

      Power input voltage 100-240V, 50/60Hz. USB charging interface.

      The smoke suction pump analyzer is equipped with a diaphragm pump with a motor installed inside, which is directly powered by the analyzer in DC mode to obtain the smoke suction force.

      Smoke probe stainless steel smoke probe, standard length 300mm, with plastic handle and adjustable positioning cone, ensuring that the top of the probe can fully extend into the flue.

      The probe can be connected to the instrument through a 3m extension cable. Can other length probes be selected (750mm, 1m, 1.5m)? The replaceable gas sensor analyzer uses electrochemical sensors to measure oxygen (O2) and (H2 compensated). It can also replace measurement sensors (NO/Low NO, NO2/Low NO2, SO2/Low SO2, CxHy, H2S).

      Regularly charging the analyzer can ensure that the electrochemical sensor is in working condition. Please avoid emptying the battery as it will be damaged if the battery level drops to 0%. The temperature sensor K-type thermocouple sensor measures the temperature of flue gas, and the host can measure flue gas temperatures up to 1250 ° C.

      The NTC thermistor sensor equipped with the measuring instrument can measure both internal temperature and ambient temperature. If the temperature control of flue gas must be carried out through the gas supply pipe (such as indoor sealed boilers), it is recommended to use TcK temperature probes (K-type thermocouples) to obtain more combustion efficiency calculation values.

      The pressure probe has two hoses for pressure sensors, which can be connected to the bottom of the analyzer. Semiconductor sensors measure suction and differential pressure, with a range of -200~+200mbar.

      Optional high-precision pressure measurement sensor, measuring range: -500~+500 Pa.

      At the bottom of the analyzer, there are two hose connection ports for flue gas input and positive and negative pressure input. One is connected to the condensate tank for connecting flue gas (black, marked as "G"), and the other is connected to the positive pressure input port (orange, marked as "P+").

      The fuel type analyzer provides data support for various common fuels.

      If necessary, operators can also manually add fuel and related data.

      The calibration of the factory calibration certificate analyzer is achieved by comparing it with the standards of the metrology laboratory, which regularly certifies its data to be close to the international authoritative laboratory level. Each analyzer is equipped with a factory calibration certificate, which indicates the reference value, measured value, allowable error limit, and discovered error of each measurement parameter.

      It is recommended to calibrate the analyzer at least once a year. The French Solman Si CA 230 multi-component flue gas analyzer comes with a 4-year warranty

    AfterSalesService :

    Key words:
    • flue gas analyzer