German Fizeafriso M650 comprehensive flue gas analyzer for desulfurization and denitrification environment
German Fizeafriso M650 comprehensive flue gas analyzer for desulfurization and denitrification environment

German Fizeafriso M650 comprehensive flue gas analyzer for desulfurization and denitrification environment

Category:

Instrumentation/Gas analyzer/flue gas analyzer

Model:

M60X

Brand:

German Fiso

model:

M60X

resolution:

1PPM

measurement object:

flue gas

measurement range:

5000ppm

power supply voltage:

two hundred and twenty

type:

portable

display mode:

electron

structural style :

handheld

Processing & Customization:

yes

gas flow rate:

five hundred

Specifications:

handheld

manufacturer:

German Fiso

Retail Price

50,000.00USD


重量

kg

  • Product Description
  • model

    M60X

    resolution

    1PPM

    measurement object

    flue gas

    measurement range

    5000ppm

    power supply voltage

    two hundred and twenty

    type

    portable

    display mode

    electron

    structural style

    handheld

    Processing & Customization

    yes

    gas flow rate

    five hundred

    Specifications

    handheld

    manufacturer

    German Fiso

    Description :

      The MAXILYZER NG plus flue gas analyzer is specifically designed for the following application areas:

      ·The setting and control measurement of various small-scale combustion systems using fuel, gas, and particulate matter as fuels, such as adjusting boiler combustion efficiency and measuring flue gas emissions; ·Due to the optional CO high concentration sensor, it is also suitable for measuring solid fuel flue gas, such as wood, coal, etc·

      Maintenance and monitoring of industrial combustion equipment (power plants/power stations/boiler production enterprises, etc.)·

      Environmental monitoring, such as safety inspection of CO emission concentration · Maintenance engineers/boiler commissioning and maintenance personnel in the industrial field 2.2 Improper use of MAXILYZER NG plus flue gas analyzer

      Prohibited for the following situations:

      ·Dangerous area (explosion-proof): If the equipment is used in a dangerous area, sparks may cause explosions, fires, or explosions.

      ·Used as a safety (alarm) device or continuous measuring equipment.

      2.3 Safe Operation The MAXILYZER NG plus flue gas analyzer adopts technical processes and strictly adheres to current safety regulations for manufacturing. The measurement standards comply with the German BImSchw regulations. Each instrument undergoes comprehensive performance and safety testing before leaving the factory. Please use the smoke analyzer under ideal environmental conditions. At the same time, it is necessary to always follow the product manual and comply with relevant local and national laws, guidelines, and safety regulations. To ensure proper use of the product, please conduct a comprehensive visual inspection before operating each instrument. The power supply voltage equipment (including all random accessories) is connected to the main power supply through a power cord, so please ensure that your line voltage meets the product requirements. The security level of the device is "1". Warning: The electric shock hazard equipment is connected to the main power supply through a power cord, so please ensure that your line voltage meets the product requirements.

      2.4 Personnel Qualification: This product can only be installed, debugged, operated, maintained, and processed by trained and qualified personnel. The electrical part of the 7 products can only be carried out by qualified electricians in accordance with local and national laws and regulations.

      2.5 For safety reasons, unauthorized personnel are prohibited from making any modifications or changes to the product, as this may result in equipment failure.

      2.6 Use of Parts and Accessories: Mismatched parts and accessories may cause damage to the equipment. Please use the original parts and accessories provided by the manufacturer (see Chapter 14)

      2.7 Disclaimer: The manufacturer shall not be held directly or indirectly responsible for any equipment damage caused by failure to fully comply with the safety information, operating instructions, or recommendations specified in the instruction manual. Manufacturers or distributors are not responsible for any costs incurred due to damage caused by users or third parties during the use of the equipment, especially in cases of improper use of the equipment, such as misuse or incorrect cable connections. Manufacturers or distributors are not responsible for equipment damage caused by users not following the instructions in the manual.

      MAXILYZER NG is a multifunctional handheld flue gas analyzer that meets the German BIMSchV emission regulations for measurement standards. The sturdy and durable protective cover has a magnetic suction function on the back, which enables hands-free operation. The LCD backlit display screen can simultaneously display 10 rows of measurement values. The instrument has the functions of displaying and resetting measured values/minimum values, graphical display of measured values, and searching for flue center temperature, ensuring convenience for users. The smoke concentration can be displayed in four different units, and the pressure value can be displayed in six different units to meet personalized detection needs. The compact design allows the device to be equipped with up to six types of sensors (O2, CO, CO/H2, NO, NO2, SO2). Calculation parameters: CO2, NOx, CO (undiluted), excess air coefficient (λ), combustion efficiency (Effi), flue gas loss qA, dew point, temperature difference, differential pressure and other important thermal parameters. 3.1 Key Functions

      Product Description: How to Translate

      M650 is a portable flue gas analyzer, with the core analysis components built into a sturdy enclosure with a protection level of IP65. It also integrates a thermal printer and a Peltier electronic cooler. The tested gas is cooled by the Peltier cooler and filtered out of dust by a fine filter before entering the electrochemical sensor inside the device for concentration analysis. The LCD backlit display screen can simultaneously display 10 rows of measurement values. The instrument has measurement value graphic display and flue center temperature search function. The built-in second air flushing pump can automatically turn on to protect the CO/H2 sensor and extend its service life. Automatically display maintenance information for easy maintenance.

      The M650 flue gas analysis system integrates a Peltier cooler, so it is mainly used in long-term measurement scenarios (automatic removal of condensed water) and for measuring high concentrations of NO2 and SO2. Because NO2 and SO2 are easily soluble in water, we must eliminate the influence of low measurement results caused by the solubility of the tested gas in water during measurement. So when detecting NO2 and SO2, it is necessary to use a heat tracing sampling tube and a gas cooler. By combining these devices, we can avoid the occurrence of the above situation. The heated gas is cooled by a cooler to remove condensed water, achieving gas water separation.

      Product application:

      The M650 enhanced flue gas analyzer is particularly suitable for high humidity, low sulfur, and flue gas detection after desulfurization and desulfurization. The instrument can be equipped with a 3m long electrically heated sampling tube to ensure NO2 during the sampling process

      SO2 will not dissolve in condensed water; At the same time, the instrument is equipped with an automatic water removal peristaltic pump, which can meet long-term online measurement requirements.

      Technical Specifications:

      

    range degree resolution Response time (T90)

      O2

      

      0 ~ 21.0 Vol.%

      

      ±0.2 Vol

      

      0.1 Vol.%

      

    <20 sT
    CO (H2 compensation) 0 ~ 4,000 ppm

      ±3 ppm (0~20ppm)

      ± 5% measurement value (>20ppm)

      

    1 ppm <30 s

      CO - Calculation

      

      0 ~ CO max

      (Based on the selected fuel)

      

      ± 0.2 vol.% measured value

      

      0.1 Vol.%

      

      <30 s

      

      NO

      

      0~2,000/ 5,000ppm

      

      ±5 ppm (0~50ppm)

      ± 5% measurement value (>50ppm)

      

      1 ppm

      

      <30 s

      

      SO2

      

      0~2,000/ 5,000ppm

      

      ±10 ppm (0~200ppm)

      ± 5% measurement value (>200ppm)

      

      1 ppm

      

      <45 s

      

      NO2

      

      0~200/ 1,000ppm

      

      ±10 ppm (0~50ppm)

      ± 10% measurement value (>50ppm)

      

      1 ppm

      

      <60 s

      

      COhigh

      

      0-4 vol.%/10 vol.%

      

      ± 5 vol.% measured value

      

      0.005 Vol.%

      

      <60 s

      

      Smoke temperature

      

      -20 ~ +1,000 °C

      

      ± 2 ° C+1 position (-20~0 ° C)

      ±1 °C 0 ( ~ 200 °C)

      ± 0.5% measurement value (>+200 ° C)

      

      1 °C

      

      <10 s

      

      ambient temperature

      

      -20 ~ +200 °C

      

      ± 2 ° C+1 position (-20~0 ° C)

      ± 0.5 ° C+1 position (0.1~+200 ° C)

      

      0.1 °C

      

      <10 s

      

      Pull/Differential Pressure

      

      ± 150 hPa

      

      ±0.02 hPa(<±2.00 hPa)

      ± 1% measurement value (>2.00 hPa)

      

      0.01 hPa

      (< 19.9 hPa)

      0.1 hPa

      (>20 hPa)

      

      <10 s

      

      Other parameters:

      Display calculated values such as CO, NOx, combustion efficiency, flue gas loss, excess air coefficient, etc

    Weight (including shell) About 6.8kg
    Dimensions (W x H x D) 410 x 175 x 330 mm
    display screen LCD screen, 60 x 80 mm
    power supply Nickel hydrogen battery pack (6V/4.5Ah)
    cooler 230V power supply
    Operating Time 24-hour continuous measurement
    data storage 100 sets of data
    communication interface miniUSB、 Infrared, optional: Bluetooth
    Operating Temperature

      -5 ℃ ~ +40 ℃

      

    Storage temperature -20 ℃ ~ +50 ℃

    AfterSalesService :

    Key words:
    • Fizeafriso
    • Germany