German Fizeafriso M650 comprehensive flue gas analyzer for desulfurization and denitrification environment
Category:
Instrumentation/Gas analyzer/flue gas analyzer
Model:
M60X
Brand:
German Fiso
model:
M60X
resolution:
1PPM
measurement object:
flue gas
measurement range:
5000ppm
power supply voltage:
two hundred and twenty
type:
portable
display mode:
electron
structural style :
handheld
Processing & Customization:
yes
gas flow rate:
five hundred
Specifications:
handheld
manufacturer:
German Fiso
Retail Price
50,000.00USD
重量
kg
- Product Description
-
model M60X
resolution 1PPM
measurement object flue gas
measurement range 5000ppm
power supply voltage two hundred and twenty
type portable
display mode electron
structural style handheld
Processing & Customization yes
gas flow rate five hundred
Specifications handheld
manufacturer German Fiso
Description :
The MAXILYZER NG plus flue gas analyzer is specifically designed for the following application areas:
·The setting and control measurement of various small-scale combustion systems using fuel, gas, and particulate matter as fuels, such as adjusting boiler combustion efficiency and measuring flue gas emissions; ·Due to the optional CO high concentration sensor, it is also suitable for measuring solid fuel flue gas, such as wood, coal, etc·
Maintenance and monitoring of industrial combustion equipment (power plants/power stations/boiler production enterprises, etc.)·
Environmental monitoring, such as safety inspection of CO emission concentration · Maintenance engineers/boiler commissioning and maintenance personnel in the industrial field 2.2 Improper use of MAXILYZER NG plus flue gas analyzer
Prohibited for the following situations:
·Dangerous area (explosion-proof): If the equipment is used in a dangerous area, sparks may cause explosions, fires, or explosions.
·Used as a safety (alarm) device or continuous measuring equipment.
2.3 Safe Operation The MAXILYZER NG plus flue gas analyzer adopts technical processes and strictly adheres to current safety regulations for manufacturing. The measurement standards comply with the German BImSchw regulations. Each instrument undergoes comprehensive performance and safety testing before leaving the factory. Please use the smoke analyzer under ideal environmental conditions. At the same time, it is necessary to always follow the product manual and comply with relevant local and national laws, guidelines, and safety regulations. To ensure proper use of the product, please conduct a comprehensive visual inspection before operating each instrument. The power supply voltage equipment (including all random accessories) is connected to the main power supply through a power cord, so please ensure that your line voltage meets the product requirements. The security level of the device is "1". Warning: The electric shock hazard equipment is connected to the main power supply through a power cord, so please ensure that your line voltage meets the product requirements.
2.4 Personnel Qualification: This product can only be installed, debugged, operated, maintained, and processed by trained and qualified personnel. The electrical part of the 7 products can only be carried out by qualified electricians in accordance with local and national laws and regulations.
2.5 For safety reasons, unauthorized personnel are prohibited from making any modifications or changes to the product, as this may result in equipment failure.
2.6 Use of Parts and Accessories: Mismatched parts and accessories may cause damage to the equipment. Please use the original parts and accessories provided by the manufacturer (see Chapter 14)
2.7 Disclaimer: The manufacturer shall not be held directly or indirectly responsible for any equipment damage caused by failure to fully comply with the safety information, operating instructions, or recommendations specified in the instruction manual. Manufacturers or distributors are not responsible for any costs incurred due to damage caused by users or third parties during the use of the equipment, especially in cases of improper use of the equipment, such as misuse or incorrect cable connections. Manufacturers or distributors are not responsible for equipment damage caused by users not following the instructions in the manual.
MAXILYZER NG is a multifunctional handheld flue gas analyzer that meets the German BIMSchV emission regulations for measurement standards. The sturdy and durable protective cover has a magnetic suction function on the back, which enables hands-free operation. The LCD backlit display screen can simultaneously display 10 rows of measurement values. The instrument has the functions of displaying and resetting measured values/minimum values, graphical display of measured values, and searching for flue center temperature, ensuring convenience for users. The smoke concentration can be displayed in four different units, and the pressure value can be displayed in six different units to meet personalized detection needs. The compact design allows the device to be equipped with up to six types of sensors (O2, CO, CO/H2, NO, NO2, SO2). Calculation parameters: CO2, NOx, CO (undiluted), excess air coefficient (λ), combustion efficiency (Effi), flue gas loss qA, dew point, temperature difference, differential pressure and other important thermal parameters. 3.1 Key Functions
Product Description: How to Translate
M650 is a portable flue gas analyzer, with the core analysis components built into a sturdy enclosure with a protection level of IP65. It also integrates a thermal printer and a Peltier electronic cooler. The tested gas is cooled by the Peltier cooler and filtered out of dust by a fine filter before entering the electrochemical sensor inside the device for concentration analysis. The LCD backlit display screen can simultaneously display 10 rows of measurement values. The instrument has measurement value graphic display and flue center temperature search function. The built-in second air flushing pump can automatically turn on to protect the CO/H2 sensor and extend its service life. Automatically display maintenance information for easy maintenance.
The M650 flue gas analysis system integrates a Peltier cooler, so it is mainly used in long-term measurement scenarios (automatic removal of condensed water) and for measuring high concentrations of NO2 and SO2. Because NO2 and SO2 are easily soluble in water, we must eliminate the influence of low measurement results caused by the solubility of the tested gas in water during measurement. So when detecting NO2 and SO2, it is necessary to use a heat tracing sampling tube and a gas cooler. By combining these devices, we can avoid the occurrence of the above situation. The heated gas is cooled by a cooler to remove condensed water, achieving gas water separation.
Product application:
The M650 enhanced flue gas analyzer is particularly suitable for high humidity, low sulfur, and flue gas detection after desulfurization and desulfurization. The instrument can be equipped with a 3m long electrically heated sampling tube to ensure NO2 during the sampling process
SO2 will not dissolve in condensed water; At the same time, the instrument is equipped with an automatic water removal peristaltic pump, which can meet long-term online measurement requirements.
Technical Specifications:
range degree resolution Response time (T90) O2
0 ~ 21.0 Vol.%
±0.2 Vol
0.1 Vol.%
<20 sT CO (H2 compensation) 0 ~ 4,000 ppm ±3 ppm (0~20ppm)
± 5% measurement value (>20ppm)
1 ppm <30 s CO - Calculation
0 ~ CO max
(Based on the selected fuel)
± 0.2 vol.% measured value
0.1 Vol.%
<30 s
NO
0~2,000/ 5,000ppm
±5 ppm (0~50ppm)
± 5% measurement value (>50ppm)
1 ppm
<30 s
SO2
0~2,000/ 5,000ppm
±10 ppm (0~200ppm)
± 5% measurement value (>200ppm)
1 ppm
<45 s
NO2
0~200/ 1,000ppm
±10 ppm (0~50ppm)
± 10% measurement value (>50ppm)
1 ppm
<60 s
COhigh
0-4 vol.%/10 vol.%
± 5 vol.% measured value
0.005 Vol.%
<60 s
Smoke temperature
-20 ~ +1,000 °C
± 2 ° C+1 position (-20~0 ° C)
±1 °C 0 ( ~ 200 °C)
± 0.5% measurement value (>+200 ° C)
1 °C
<10 s
ambient temperature
-20 ~ +200 °C
± 2 ° C+1 position (-20~0 ° C)
± 0.5 ° C+1 position (0.1~+200 ° C)
0.1 °C
<10 s
Pull/Differential Pressure
± 150 hPa
±0.02 hPa(<±2.00 hPa)
± 1% measurement value (>2.00 hPa)
0.01 hPa
(< 19.9 hPa)
0.1 hPa
(>20 hPa)
<10 s
Other parameters:
Display calculated values such as CO, NOx, combustion efficiency, flue gas loss, excess air coefficient, etc
Weight (including shell) About 6.8kg Dimensions (W x H x D) 410 x 175 x 330 mm display screen LCD screen, 60 x 80 mm power supply Nickel hydrogen battery pack (6V/4.5Ah) cooler 230V power supply Operating Time 24-hour continuous measurement data storage 100 sets of data communication interface miniUSB、 Infrared, optional: Bluetooth Operating Temperature -5 ℃ ~ +40 ℃
Storage temperature -20 ℃ ~ +50 ℃ AfterSalesService :
Key words:- Fizeafriso