Fossil oil and gas storage tanksIt is a commonly used equipment for storing liquefied petroleum gas. Due to the flammable and explosive nature of this gas, when designing this type of storage tank, attention should be paid to its differences from general gas storage tanks, especially safety, as well as its characteristics in manufacturing, installation, and other aspects.
Horizontal liquefied petroleum gas storage tankIt is also a storage pressure vessel and should be manufactured, tested, and accepted in accordance with GB150 "Steel Pressure Vessels"; And accept the supervision of the "Regulations on Safety Technology Supervision of Pressure Vessels" (referred to as the "Regulations") issued by the Ministry of Labor. Liquefied petroleum gas storage tanks, whether horizontal or spherical, belong to the third category of pressure vessels.LPG storage tankIt mainly consists of a cylinder, a head, a manhole, supports, and various connecting pipes.Liquefied gas storage tankThere are liquid phase pipes, gas phase pipes, sewage pipes, as well as pressure gauges, thermometers, liquid level gauges, etc.
Technical requirements for the design of a 30 cubic meter above ground horizontal liquefied petroleum gas storage tank
The Q345R steel plate used for equipment shall comply with GB713-2014 regulations and be supplied in hot-rolled state; Ultrasonic testing should be conducted one by one, with a qualification level lower than Level II; The manhole flange cover shall be supplied in a normalized state and subjected to a -20 ℃ low-temperature impact test with an impact energy of not less than 41J. The 10 steel pipes used for equipment shall comply with GB9948-2013 regulations and be supplied in a normalized state. The 16Mn forgings used for equipment shall meet the requirements of Level II in NB/T47008-2010, be supplied in a normalized state, and undergo a -20 ℃ low-temperature impact test with an impact energy of not less than 34J.
The form and size of welding joints shall comply with the provisions of HG/T20583-2011: DU4, DU25 or DU29 shall be used for welding of butt joints; The welding between the takeover and the shell adopts G4 (full welding), and the welding between the takeover with reinforcement ring and the shell adopts G29 (full penetration welding); Polish the welded rear end of the takeover and shell smooth (without sharp corners); Takeover without additional reinforcement shall not be located on Class A or B welded streets; The weld leg size of the fillet weld should be based on the thickness of the thinner one and should have a concave smooth transition; The welding of flanges shall be carried out in accordance with the corresponding flange standards.
After the equipment inspection is qualified, the overall rust removal of the outer surface is carried out, and two coats of anti rust primer and topcoat are applied. A red color band with a width of 150mm is painted along the horizontal centerline of the tank body. The words "No Smoking" are sprayed above the center of gravity sign, and the height of the sign and words is not less than 200mm. The packaging and transportation shall comply with the provisions of JB/T4711-2003 "Coating and Transport Packaging for Pressure Vessels".
After heat treatment, welding is not allowed except on the pre welded plate.
The discharge outlet of the safety valve should be equipped with a conduit to guide the discharge medium to a safe location and handle it properly. It should not be directly discharged into the atmosphere.
The equipment should have an electrostatic grounding device with a grounding resistance not exceeding 10 ohms.
The equipment should be installed at a tilt angle of 3/1000, so that the discharge outlet d is in a low position.
Users should be equipped with sliding end saddle foundation pads in accordance with Appendix C of JB/T4712.1-2007
The safety valve adopts a spring fully open closed safety valve, model A42F-25, DN100, with a spring pressure rating of 1.6~2.0MPa.
It is recommended to use Y-150 (0~4.0MPa) pressure gauge with a grade of 1.6.
It is recommended to use a bimetallic thermometer WSS501. -40 ℃~80 ℃ (with a red line at 48 ℃~50 ℃) L=300, grade 1.5.
The recommended model for the liquid level gauge is UZ2.5M-2200-0.56AF 304
10. The orientation of the pipe mouth and saddle is shown in this diagram
Note 1: Without actual components, the saturated vapor pressure at 50 ℃ is less than or equal to 1.61MPa, and the H2S content is less than 7.7mg/l.
Note 2: The design service life is the expected service life of the equipment, and the time service life is determined based on actual usage and inspection results.
Manufacturer of 5-200 cubic liquefied gas storage tanks and 50 cubic liquefied gas storage tanks
In recent years, Heze Boiler Factory Co., Ltd. has made significant progress in the research and production of pressure vessels,Liquefied gas storage tankIt is also one of the company's leading products and has become one of the largest fixed products in Chinalpg tank The manufacturer has Class III pressure vessel design qualification, Class III pressure vessel manufacturing qualification, and GC2 pressure pipeline installation qualification. In product design and production, the established enterprise standards are higher than the requirements of national safety technical specifications and standards such as "Solid Capacity Regulations", GB150 "Pressure Vessels", NB/T47001 "Steel Liquefied Petroleum Gas Horizontal Storage Tank Types and Basic Parameters". Based on our rich practical experience and data, we have optimized our product design to ensure safety, reliability, reasonable structure, energy efficiency, and low consumption. Over 20000 units have been manufacturedLiquefied gas storage tankThere has never been a safety or quality accident with any of them.
Safety accessories for liquefied gas storage tanks
1) Safety valve
The safety valve is an important safety device of this product. Under normal circumstances, the safety valve should be sealed and closed. In the event of abnormal pressure inside the tank due to temperature rise, fire, operational errors, etc., when the pressure reaches the set pressure of the safety valve, the safety valve will automatically open and begin to release pressure. When the pressure drops to the reseating pressure of the safety valve, the safety valve will automatically close and restore the normal sealing state, thereby ensuring the safe use and economy of the product.
The discharge outlet of the safety valve should be equipped with a conduit to guide the discharge medium to a safe location and handle it properly. It should not be directly discharged into the atmosphere to ensure the safety and environmental protection of the product.
The safety valve model of this product is A42F-25, DN100, with a spring pressure rating of 1.6-2.0MPa.
2) Pressure gauge
A pressure gauge is a device used by equipment operators to observe and monitor pressure changes inside a tank. A red warning sign should be painted above the scale of 1.77MPa on the pressure gauge dial. The pressure gauge can be equipped with a shut-off valve for regular inspection or replacement. However, under normal operating conditions of the equipment, the shut-off valve should be fully opened and sealed with lead to ensure the accuracy of pressure monitoring inside the tank.
The recommended model for this product's pressure gauge is Y-100 (0-4.0MPa), with an accuracy level of 1.6.
3) Thermometer
A thermometer is a device used by equipment operators to observe and monitor temperature changes inside a tank. Mark the thermometer dial with a red warning symbol indicating a temperature range of 48 ℃ to 50 ℃.
Recommended model of thermometer for this product: WSS501-40 ℃~80 ℃ L=300mm.
4) Liquid level gauge
A liquid level gauge is a device used by equipment operators to observe and grasp changes in the liquid level height inside a tank. The filling height and above of the liquid level gauge should be marked with a red warning sign.
The recommended model for the liquid level gauge of this product is UZ2.5M-2800-0.56AF 304.