Description :
Liquefied gas storage tankIn the design and production process, the established enterprise standards are higher than the requirements of national safety technical specifications and standards such as "Solid Capacity Regulations", GB150 "Pressure Vessels", NB/T47001 "Steel Liquefied Petroleum Gas Horizontal Storage Tank Types and Basic Parameters". Based on our rich practical experience and data, we have optimized our product design to ensure safety, reliability, reasonable structure, energy efficiency, and low consumption. Over the past 30 years, more than 20000 liquefied gas storage tanks have been produced without any safety or quality accidents, ensuring quality assurance,Liquefied gas storage tank priceFairness.
Liquefied gas storage tankRepair precautions:
1) Major product repairs should be carried out by units with corresponding repair qualifications.
2) Before major repairs are carried out, written notification should be given to the registration authority for the use of pressure vessels.
3) Before entering the interior of the container, repair personnel should follow the requirements of the "Safety Technical Supervision Regulations for Fixed Pressure Vessels" and prepare and clean the container. If the requirements are not met, personnel are strictly prohibited from entering.
4) Internal cleaning and replacement before repair: Use a hydrocarbon pump to pump the liquefied petroleum gas from the storage tank to be repaired into the in use storage tank. After the liquid liquefied petroleum gas is pumped out, use a compressor to pump the gaseous petroleum gas into the in use storage tank. Stop pumping when the pressure reaches about 0.05MPa. Then inject water into the storage tank, stop the water intake when the water level rises to near the height of the gas-phase pipe opening, and soak for at least 24 hours. Set up water seals and combustion nozzles, and use water pressure to seal the remaining air pressure in the tank to the combustion nozzle for incineration; Alternatively, inert gas can be used for displacement treatment. Afterwards, analysis of oxygen content and gas concentration in the tank should be conducted. The content of liquefied gas should be below the lower explosive limit, and replacement is considered qualified. After passing the analysis, the tank can be put into operation.
5) Develop a repair plan and approve it according to regulations, specifying that there shall be no human damage or structural discontinuity at the repair site, and ensuring that the equipment's intrinsic safety meets regulatory requirements.
6) Implement, inspect, test (including supervision) and record and report according to the repair plan.
7) The specific operational matters on site shall be subject to the requirements of the safety supervision agency where the equipment is used.
Heze Boiler Factory Co., LtdHaving multiple complete pressure vessel production lines, advanced tooling equipment is used for various processes such as cutting and forming, assembly, welding, heat treatment, pressure testing, shot blasting and rust removal, painting, etc. This ensures product quality and timely delivery of orders.
Liquefied gas storage tankSafety operating procedures
Storage tank liquid inlet operation procedure
1. Preparation work
① Check the liquid level, pressure, and temperature of the incoming storage tank and fill in the patrol inspection record.
② Confirm to use a liquefied petroleum gas pump or a liquefied petroleum gas compressor to operate the liquid inlet.
2. Operating procedure for liquid injection with liquefied petroleum gas pump
① Open the valve from the gas phase outlet of the liquid storage tank to the gas phase pipeline of the liquefied petroleum gas tanker truck.
② Open the valve from the liquid phase outlet of the liquefied petroleum gas tanker to the inlet pipeline of the liquefied petroleum gas pump. Open the valve of the liquid phase inlet pipeline from the outlet of the liquefied petroleum gas pump to the inlet tank.
③ Notify the operator to start the liquefied petroleum gas pump.
④ When the liquid level indicator of the tanker truck approaches zero, the liquid inlet is completed and the operator is notified to stop the pump.
⑤ Close the gas and liquid phase valves mentioned above for this assignment.
⑥ Fill in the operation record form according to regulations.
3. Operating Procedure for Liquid Filling with Liquefied Petroleum Gas Compressor
① Open the valve from the gas phase outlet of the liquid storage tank to the inlet pipeline of the liquefied petroleum gas compressor, and open the valve from the outlet of the liquefied petroleum gas compressor to the gas phase pipeline of the liquefied petroleum gas tanker truck.
② Open the valve from the liquid phase inlet of the storage tank to the liquid phase pipeline of the liquefied petroleum gas tanker truck.
③ Notify the operator to start the compressor and input the liquefied petroleum gas from the tanker into the liquid storage tank.
④ When the liquid level indicator of the tanker truck approaches zero, the liquid inlet is completed and the operator is notified to stop the machine.
⑤ Close the gas and liquid phase valves mentioned above for this assignment.
⑥ Fill in the operation record form according to regulations.
4. Precautions
① It is strictly prohibited to overfill during liquid filling. When the liquid level gauge shows no change, stop the liquid filling operation and troubleshoot.
② The filling pressure should be ≤ 1.5MPa. The liquid temperature should be ≤ 50 ℃. When the liquid temperature reaches 40 ℃, cooling water should be sprayed to reduce the temperature.
③ It is not allowed to fill two storage tanks at the same time.
Operating Procedure for Tank Discharge
1. Preparation work
① Check the liquid level, pressure, and temperature of the storage tank and fill in the patrol inspection record.
② Confirm the use of a liquefied petroleum gas pump or a liquefied petroleum gas compressor for liquid supply operation.
Operating Procedure for Liquid Extraction with Liquefied Petroleum Pump
⑴ Supply liquid from the discharge tank to the filling gas cylinder
① Open the gas phase pipeline valve from the liquid storage tank to another storage tank.
② Open the valve of the pipeline from the liquid phase outlet of the liquid storage tank to the inlet of the liquefied petroleum gas pump. Open the valve from the liquefied petroleum gas pump outlet to the filling main pipe.
③ Notify the operator to start the liquefied petroleum gas pump according to the regulations.
④ The filling of the gas cylinder is completed, notify the operator to stop the pump.
⑤ Close the gas and liquid phase valves mentioned above for this assignment.
⑥ Fill in the operation record form according to regulations.
⑵ Supply liquid from the liquid storage tank to the liquefied petroleum gas tanker truck
① Open the valve from the gas phase outlet of the liquid storage tank to the gas phase pipeline of the liquefied petroleum gas tanker truck.
② Open the valve from the liquid phase outlet of the liquid storage tank to the inlet pipeline of the liquefied petroleum gas pump. Open the valve from the liquefied petroleum gas pump outlet to the liquid phase pipeline of the liquefied petroleum gas tanker truck.
③ Notify the operator to start the liquefied petroleum gas pump and supply liquefied petroleum gas to the liquefied petroleum gas tanker truck.
④ When the liquid level of the tanker reaches the high allowable filling level, the loading is completed and the operator is notified to stop the pump.
⑤ Close the gas and liquid phase valves mentioned above for this assignment.
⑥ Fill in the operation record form according to regulations.
Operating Procedure for Liquid Discharge of Liquefied Petroleum Gas Compressor
⑴ Supply liquid from the discharge tank to the filling gas cylinder
① Open the valve from the gas phase outlet of the gas supply tank to the inlet pipeline of the liquefied petroleum gas compressor. Open the valve of the gas phase inlet pipeline from the outlet of the liquefied petroleum gas compressor to the outlet storage tank.
② Open the valve from the liquid phase outlet of the liquid storage tank to the filling main pipe.
③ Notify the operator to start the compressor.
④ The filling of the gas cylinder is completed, and the operator is notified to stop the machine.
⑤ Close the gas and liquid phase valves related to this assignment.
⑥ Fill in the operation record form according to regulations
⑵ Supply liquid from the liquid storage tank to the liquefied petroleum gas tanker truck
① Open the valve from the gas phase port of the liquefied petroleum gas tanker to the inlet pipeline of the liquefied petroleum gas compressor, and open the valve from the outlet of the liquefied petroleum gas compressor to the gas phase inlet pipeline of the discharge tank.
② Open the valve from the liquid phase outlet of the liquid storage tank to the liquid phase pipeline of the liquefied petroleum gas tanker truck.
③ Notify the operator to start the compressor,.
④ When the liquid level of the tanker reaches the high allowable filling level, the discharge of the liquid storage tank ends and the operator is notified to stop the machine.
⑤ Close the gas and liquid phase valves related to this assignment. ⑥ Fill in the operation record form according to regulations.
4. Precautions
① Check the change in liquid level and find that the liquid level in the outlet storage tank does not rise or fall. The vehicle should be stopped for inspection.
② Check the pressure changes. When using a compressor for operation, the pressure in the discharge tank should be 0.2MPa to 0.5MPa higher than that in the supply tank. Otherwise, stop the machine for inspection
③ When using a liquefied petroleum gas pump, special attention should be paid to the point where the liquid level in the discharge tank drops close to 5cm above the bottom of the tank. If it may not be possible to supply liquid, the pump should be stopped and the discharge tank should be replaced in a timely manner.




AfterSalesService :