  • Product Description
  • Description :

    ? Before installing a new boiler, it is necessary to inform the local special equipment safety supervision and management department in writing for filing.

    ? Entrust the design institute to design the boiler room and its layout.

    ? Choose a qualified installation unit with experience in installing fuel (gas) boilers.

    The system layout and installation of this series of boilers should comply with the following specifications and standards:

      Regulations on Safety Supervision of Special Equipment.

      TSG G0001-2012 Boiler Safety Technical Supervision Regulations.

      GB50041-2008 "Design Code for Boiler Room".

      GB50273-2009 "Code for Construction and Acceptance of Boiler Installation Engineering".

      Other technical documents provided by our factory.

    boiler room

      Boilers should generally be installed in separate boiler rooms, and newly built boiler rooms should not be connected to residential buildings.

      The boiler room shall not be connected to Class A and Class B fire hazard rooms or Class C fire hazard rooms that use flammable liquids. If connected to other production plants, firewalls should be used to separate them.

      The fire resistance rating and fire prevention requirements of the boiler room building should comply with the requirements of the "Code for Fire Protection Design of Buildings" and the "Code for Fire Protection Design of High rise Civil Buildings".

      The boiler room should adopt a light roof and can also have explosion venting windows on the exterior walls. The window area and pressure relief port should not be less than 10% of the boiler's floor area. The explosion site shall not be adjacent to crowded rooms and passages.

      The normal ventilation of the boiler room is the basic condition for ensuring the normal combustion of the boiler. The boiler room should be equipped with suitable ventilation openings to provide fresh air to the boiler and avoid adverse combustion.

      The size of the boiler room should fully meet the space required for the operation, maintenance, and repair of the boiler and its ancillary equipment.

      The floor of the boiler room should be flat, non flammable, and free of standing water; The bearing capacity of the foundation should meet the requirements.

      The lighting and electrical switches in the boiler room are explosion-proof.

      Gas leakage detection and alarm devices should be installed in the boiler room that burns gas fuel.