      Daily maintenance methods for liquid nitrogen storage tanks

      1. Whether the gate valve and pipeline are leaking, and whether the casing is frosting or sweating.

      2. Whether the gate valve is in normal opening and closing condition.

      3. Whether the appearance (liquid level transmitter, pressure gauge) is working properly, and whether the main parameters of DCS and the on-site primary gauge are interrelated.

      4. Is the working pressure of the storage tank normal? When the working pressure approaches or is equivalent to a higher working pressure, the air valve needs to be opened to relieve pressure.

      5. Has the liquid storage rate exceeded 95%.

      6. Regarding the thermal insulation storage tank for superheated steam powder, is the sealing gas normal. (50mmH2O)

      7. Avoid placing flammable, explosive, and dirty materials adjacent to liquid nitrogen storage tanks.

      8. The liquid nitrogen storage tanks are adjacent to each other to prevent fireworks.