Shandong 2-ton Gas Steam Boiler National Standard Customization Shandong Integrity Enterprise Supplier
Shandong 2-ton Gas Steam Boiler National Standard Customization Shandong Integrity Enterprise Supplier

Shandong 2-ton Gas Steam Boiler National Standard Customization Shandong Integrity Enterprise Supplier

Category:

mechanical equipment/Industrial boilers and accessories/Gas boiler

Model:

WNS2-1.25-Q

Brand:

Zhongjie Special Equipment

Retail Price

145,000.00USD


重量

kg

  • Product Description
  • Description :

      Reasonable design:Horizontal internal combustion three pass fully wet back design, waveform furnace chamber, with good thermal expansion and contraction. The overall design of water in fire, sufficient heating area, and reasonable structural layout are the guarantees for the efficient operation of the boiler.

      Efficient and energy-saving:The thermal efficiency of steam and hot water boiler series is between 90% and 95%. A large combustion chamber with a reasonable structural layout can transfer more heat into the water, greatly improving the heat exchange capacity between fuel steam and fuel hot water.

      Compliant with environmental requirements:The combustion chamber has a large space, making full use of radiation heat exchange, and with reliable imported burners, the fuel can be completely burned, greatly reducing the emission of harmful components in the flue gas. After testing by the statutory department, our company's fuel (gas) steam and hot water boilers meet national environmental protection requirements and are ideal environmentally friendly products.

      Excellent configuration:Equipped with world-class burners, advanced control systems (mainly imported components), valves, and pumps all adopt national products, and excellent boiler accessory configurations provide strong guarantees for the safe and stable operation of the boiler.

      Fully automatic operation:Users only need to press the start button, and the boiler will run according to the set program. Load regulation, water supply, etc. are all fully automatic and do not require special supervision.

      Easy maintenance and repair:There are movable smoke box doors at the front and rear of the boiler, and observation and inspection holes at the rear for entering the furnace for inspection and cleaning. Manholes are provided on the furnace body, and the structural design fully considers the convenience of future maintenance.

      WNS Series Fully Automatic Fuel (Gas) Steam Boiler Technical Parameters Table 1

    model WNS0.5-0.4

      -Y(Q)

      

    WNS0.5-0.7

      -Y(Q)

      

    WNS1.0-0.7

      -Y(Q)

      

    WNS1.0-1.0

      -Y(Q)

      

    WNS2-1.0

      -Y(Q)

      

    WNS2-1.25

      -Y(Q)

      

    WNS4-1.0

      -Y(Q)

      

    WNS4-1.25

      -Y(Q)

      

    WNS4-1.6

      -Y(Q)

      

    Rated evaporation capacity t/h zero point five zero point five one one two two four four four
    Rated working pressure Mpa zero point four zero point seven zero point seven one one one point two five one one point two five one point six
    Rated steam temperature ℃ one hundred and fifty-one one hundred and seventy point four one hundred and seventy point four one hundred and eighty-four one hundred and eighty-four one hundred and ninety-three one hundred and eighty-four one hundred and ninety-three two hundred and four
    Rated feedwater temperature ℃ twenty twenty twenty twenty twenty twenty twenty twenty twenty
    Main body heat exchange area ㎡ thirteen point zero eight four thirteen point zero eight four twenty point four seven twenty-eight point zero four forty-five point three six forty-five point three six ninety point four ninety point four ninety point four
    Energy saving device heat exchange area ㎡ seven point nine eight eight point one zero five eight point nine one five four point two three twenty-eight point zero six twenty-eight point zero six fifty-four point one fifty-four point one fifty-four point one
    Design fuel O-type light diesel natural gas
    Fuel consumption kg/h/Nm3/h Oil/Gas thirty-four point nine three

      forty-two point three six

      

    thirty-five point five six

      forty-three point one four

      

    sixty-three point five

      seventy-one point five

      

    sixty-nine point one one

      eighty-three point eight five

      

      

    one hundred and forty-one point seven eight

      one hundred and seventy point eight one

      

    two hundred and seventy-seven

      three hundred and thirty-three

      

    two hundred and eighty-nine point eight

      three hundred and thirty-four point zero five

      

    three hundred and five

      three hundred and forty

      

    Design thermal efficiency%

      Fuel/Gas

      

    ninety-one point three three

      ninety-two point two zero

      

    ninety point zero five

      ninety-one point two zero

      

    ninety-three point one zero

      ninety-three point three zero

      

    ninety-one point three seven

      ninety-one point two one

      

    ninety-one point four nine

      ninety-two point zero nine

      

    ninety-one point zero nine

      ninety-one point seven nine

      

    ninety-one point eight six

      ninety-two point seven eight

      

    ninety-one point five

      ninety-two point seven

      

    ninety-one point three

      ninety-two point five

      

    Exhaust gas temperature ℃ one hundred and ninety-seven point one five

      one hundred and eighty-seven point one two

      

    two hundred and ten point five three

      two hundred and four point five nine

      

    one hundred and forty-two point eight

      one hundred and twenty-five point four

      

    one hundred and fifty-nine point four four

      one hundred and fifty-five point four three

      

      

    one hundred and fifty-four point eight five

      

      

    one hundred and sixty point two

      one hundred and forty-nine point one

      

      

    Chimney specification mm * m Φ270*8 Φ270*8 Φ273*8 Φ273*8 Φ325*8 Φ325*8 Φ450*10 Φ450*10 Φ450*10
    Main steam valve specification mm DN50 DN50 DN50 DN50 DN80 DN80 DN100 DN100 DN100

    AfterSalesService :

    Key words:
    • Shandong steam boiler