Shandong 2-ton Gas Steam Boiler National Standard Customization Shandong Integrity Enterprise Supplier
Category:
mechanical equipment/Industrial boilers and accessories/Gas boiler
Model:
WNS2-1.25-Q
Brand:
Zhongjie Special Equipment
Retail Price
145,000.00USD
重量
kg
- Product Description
-
Description :
Reasonable design:Horizontal internal combustion three pass fully wet back design, waveform furnace chamber, with good thermal expansion and contraction. The overall design of water in fire, sufficient heating area, and reasonable structural layout are the guarantees for the efficient operation of the boiler.
Efficient and energy-saving:The thermal efficiency of steam and hot water boiler series is between 90% and 95%. A large combustion chamber with a reasonable structural layout can transfer more heat into the water, greatly improving the heat exchange capacity between fuel steam and fuel hot water.
Compliant with environmental requirements:The combustion chamber has a large space, making full use of radiation heat exchange, and with reliable imported burners, the fuel can be completely burned, greatly reducing the emission of harmful components in the flue gas. After testing by the statutory department, our company's fuel (gas) steam and hot water boilers meet national environmental protection requirements and are ideal environmentally friendly products.
Excellent configuration:Equipped with world-class burners, advanced control systems (mainly imported components), valves, and pumps all adopt national products, and excellent boiler accessory configurations provide strong guarantees for the safe and stable operation of the boiler.
Fully automatic operation:Users only need to press the start button, and the boiler will run according to the set program. Load regulation, water supply, etc. are all fully automatic and do not require special supervision.
Easy maintenance and repair:There are movable smoke box doors at the front and rear of the boiler, and observation and inspection holes at the rear for entering the furnace for inspection and cleaning. Manholes are provided on the furnace body, and the structural design fully considers the convenience of future maintenance.
WNS Series Fully Automatic Fuel (Gas) Steam Boiler Technical Parameters Table 1
model WNS0.5-0.4 -Y(Q)
WNS0.5-0.7 -Y(Q)
WNS1.0-0.7 -Y(Q)
WNS1.0-1.0 -Y(Q)
WNS2-1.0 -Y(Q)
WNS2-1.25 -Y(Q)
WNS4-1.0 -Y(Q)
WNS4-1.25 -Y(Q)
WNS4-1.6 -Y(Q)
Rated evaporation capacity t/h zero point five zero point five one one two two four four four Rated working pressure Mpa zero point four zero point seven zero point seven one one one point two five one one point two five one point six Rated steam temperature ℃ one hundred and fifty-one one hundred and seventy point four one hundred and seventy point four one hundred and eighty-four one hundred and eighty-four one hundred and ninety-three one hundred and eighty-four one hundred and ninety-three two hundred and four Rated feedwater temperature ℃ twenty twenty twenty twenty twenty twenty twenty twenty twenty Main body heat exchange area ㎡ thirteen point zero eight four thirteen point zero eight four twenty point four seven twenty-eight point zero four forty-five point three six forty-five point three six ninety point four ninety point four ninety point four Energy saving device heat exchange area ㎡ seven point nine eight eight point one zero five eight point nine one five four point two three twenty-eight point zero six twenty-eight point zero six fifty-four point one fifty-four point one fifty-four point one Design fuel O-type light diesel natural gas Fuel consumption kg/h/Nm3/h Oil/Gas thirty-four point nine three forty-two point three six
thirty-five point five six forty-three point one four
sixty-three point five seventy-one point five
sixty-nine point one one eighty-three point eight five
one hundred and forty-one point seven eight one hundred and seventy point eight one
two hundred and seventy-seven three hundred and thirty-three
two hundred and eighty-nine point eight three hundred and thirty-four point zero five
three hundred and five three hundred and forty
Design thermal efficiency% Fuel/Gas
ninety-one point three three ninety-two point two zero
ninety point zero five ninety-one point two zero
ninety-three point one zero ninety-three point three zero
ninety-one point three seven ninety-one point two one
ninety-one point four nine ninety-two point zero nine
ninety-one point zero nine ninety-one point seven nine
ninety-one point eight six ninety-two point seven eight
ninety-one point five ninety-two point seven
ninety-one point three ninety-two point five
Exhaust gas temperature ℃ one hundred and ninety-seven point one five one hundred and eighty-seven point one two
two hundred and ten point five three two hundred and four point five nine
one hundred and forty-two point eight one hundred and twenty-five point four
one hundred and fifty-nine point four four one hundred and fifty-five point four three
one hundred and fifty-four point eight five one hundred and sixty point two one hundred and forty-nine point one
Chimney specification mm * m Φ270*8 Φ270*8 Φ273*8 Φ273*8 Φ325*8 Φ325*8 Φ450*10 Φ450*10 Φ450*10 Main steam valve specification mm DN50 DN50 DN50 DN50 DN80 DN80 DN100 DN100 DN100 


AfterSalesService :
Key words:- Shandong steam boiler
More Products