Eight Precautions for Daily Use of LNG Storage Tanks by Zhongjie Equipment LNG Storage Tank Manufacturer
Category:
mechanical equipment/Storage and transportation equipment/storage tank
Model:
CFW60-0.8
Brand:
Zhongjie Special Equipment
model:
CFW60-0.8
material:
stainless steel
capacity:
fifty-four
storage location:
Ground storage tank
Product Usage:
Storage tank
Placement method:
horizontal storage tank
structural form:
horizontal
Processing & Customization:
yes
Applicable materials:
LNG Tank
volume:
fifty-four
Overall dimensions:
DN2400-12400-8
self-weight:
two hundred and nineteen thousand and six hundred
Place of Origin:
Heze, Shandong
container type:
The first type of pressure vessel
Special Equipment Manufacturing License Number:
A2
weight:
two hundred and nineteen thousand and six hundred
Operating Temperature:
one hundred and ninety-three
work pressure:
zero point eight
diameter:
DN2400
height:
one hundred and twenty-four thousand
type:
Anti corrosion storage tank
Retail Price
316,000.00USD
重量
kg
- Product Description
-
model CFW60-0.8
material stainless steel
capacity fifty-four
storage location Ground storage tank
Product Usage Storage tank
Placement method horizontal storage tank
structural form horizontal
Processing & Customization yes
Applicable materials LNG Tank
volume fifty-four
Overall dimensions DN2400-12400-8
self-weight two hundred and nineteen thousand and six hundred
Place of Origin Heze, Shandong
container type The first type of pressure vessel
Special Equipment Manufacturing License Number A2
weight two hundred and nineteen thousand and six hundred
Operating Temperature one hundred and ninety-three
work pressure zero point eight
diameter DN2400
height one hundred and twenty-four thousand
type Anti corrosion storage tank
Description :
LNGtankNatural gas storage tanks, with the increasing use of natural gas, LNG storage tanks are becoming more and more commonly used. However, what precautions should be taken in the daily use of LNG storage tanks?
1、 For storage tanks with double root valves, the valves near the tank should be normally open.
2、 When unloading, it is recommended that the maximum filling capacity of the LNG storage tank should not exceed 90% of the effective volume (85% -95% of the geometric volume given by the manufacturer), and the remaining usage should not be less than 10%.
3、 When the pressure of an LNG storage tank is high, it does not necessarily mean that there is a problem with the tank. The leakage heat and storage time of the entire system should be considered. Generally, when the pressure exceeds 1.1 MPa, it is necessary to discharge and release the pressure. Prolonged high pressure in the tank will affect the service life of the vacuum in the tank interlayer.




4、 When there is a large amount of long-term sweating or frosting in the LNG storage tank, and the pressure keeps rising rapidly, the vacuum failure should be considered, and emergency treatment should be carried out by manually draining the pressure and transferring the LNG liquid in the tank.
6、 It is recommended to conduct a vacuum test on LNG storage tanks every year. When the tank is a hot tank, the vacuum degree should be less than 1Pa, and when the tank is a cold tank, the vacuum degree should be less than 0.5Pa (0.00375TOF) to be qualified.
7、 The storage tank cannot be transported with liquid, and the LNG liquid inside the tank should be discharged when it is not in use for a long time.
8、 LNG storage tanks are pressure vessel equipment. According to the requirements of the "Safety Technical Supervision Regulations for Pressure Vessels" issued and implemented, the installation, maintenance, and renovation of pressure vessels require qualified units to inform the local quality inspection department and obtain permission before installation, maintenance, and renovation can be carried out.
AfterSalesService :
Key words:- LNG tank manufacturer