Spot RB-92S-4 high-pressure fan 25kw/380V three-phase double bladed high-pressure blower
Spot RB-92S-4 high-pressure fan 25kw/380V three-phase double bladed high-pressure blower

Spot RB-92S-4 high-pressure fan 25kw/380V three-phase double bladed high-pressure blower

Category:

Environmental Protection/Fan exhaust equipment/High pressure fan

Model:

RB-92S-4

Brand:

TWyx/All Wind

Retail Price

8,100.00USD


重量

kg

  • Product Description
  • Description :

    Product model: RB-92S-4
    Voltage: three-phase 50/60HZ Input voltage: 345-415 △/600-720Y
    Rated power: 25KW Flow rate: 1110/1310m3/h
    Suction: 440/440mbar Blowing force: 590/540mbar
    Noise: 74dB (A) Weight: 211Kg

      Dimensions: 812 * 615 * 607 Inlet and outlet diameters: 4 inches (100)

      Precautions for using vacuum vortex air pump

      Before using the fan again, it is necessary to carefully check whether the voltage and frequency indicated on the product nameplate meet local requirements, and strictly operate it according to the rated voltage of the motor

      Before running the fan, it is necessary to check whether there is any collision or friction between the fan blades and the casing, whether the motor is grounded, and whether the insulation is good

      Before running the fan, it is necessary to check whether the rotation direction of the impeller is correct. If there are any abnormal sounds or vibrations during the trial operation, the fan should be stopped immediately, the power should be cut off for troubleshooting, and it can only be used after it is normal

      When the air intake of the fan is vertically downward or upward, the pressure bearing of the motor should be replaced before use

      5. The temperature of mesons transported by the fan should not exceed 80 degrees Celsius

      6. Fans should not be used in areas where water is easily sprayed or directly exposed to rain

      7. Fans should not be used in environments where chemical gases are corrosive, flammable, or explosive

      8. The foundation or support for fastening the fan must be firm

      9. The connection of the fan pipeline network should be stable, and the weight of the pipeline should not be added to the various components of the fan

      When a regulating valve is installed in the pipeline, the inlet regulating valve of the fan should be turned off before shutting down, and the outlet regulating valve should be slightly opened. After the fan is running normally, gradually open the regulating valve.

      