Oxygen metal tube float flowmeter manufacturer
Category:
Instrumentation/Flow meter/Rotameter
Model:
LZZ
Brand:
Xinwang
brand:
Xinwang
model:
LZZ
connection method:
flange
measurement range:
10-100L/MIN
power supply voltage:
24VDC
accuracy class:
2.5, 1.5
Protection level:
IP65
Nominal Diameter:
Flow rate 10-100L/MIN
Operating Temperature:
-40℃~+350℃
work pressure:
0.2-0.7
output method:
4-20mA current output
display mode:
Remote transmission display
Applicable Medium:
Strong acids, strong bases, oxidants, organic solvents, corrosive gases, liquids, nitric acid, sulfuric acid, hydrochloric acid, acetone
material:
304 stainless steel
Processing & Customization:
yes
Whether it is imported:
No
Overall dimensions:
two hundred and fifty
Place of Origin:
Jiangsu
manufacturer:
Xinwang Instrument
Retail Price
800.00USD
重量
kg
- Product Description
-
brand Xinwang
model LZZ
connection method flange
measurement range 10-100L/MIN
power supply voltage 24VDC
accuracy class 2.5, 1.5
Protection level IP65
Nominal Diameter Flow rate 10-100L/MIN
Operating Temperature -40℃~+350℃
work pressure 0.2-0.7
output method 4-20mA current output
display mode Remote transmission display
Applicable Medium Strong acids, strong bases, oxidants, organic solvents, corrosive gases, liquids, nitric acid, sulfuric acid, hydrochloric acid, acetone
material 304 stainless steel
Processing & Customization yes
Whether it is imported No
Overall dimensions two hundred and fifty
Place of Origin Jiangsu
manufacturer Xinwang Instrument
Description :
Metal tube float flowmeterOverview The standard LZ series metal tube float flowmeter consists of a measuring tube and a local indicator. Local indicators can also be equipped with additional electrical components, suitable for measuring liquids and gases. This flowmeter adopts the principle of variable area measurement, and the measuring component consists of a conical measuring tube and a float. The float can freely move up and down in the conical measuring tube, changing the flow area in the pipeline. As the flow rate changes, the vertical position of the float in the measuring tube also changes accordingly. The position of the float is transmitted to the dial of the indicator through a magnetic transmission system in a steel pipe, indicating the size of the flow value.
In M6, M8, M9 indicators, the rotation of the follower magnet is directly transmitted to the dial; In the M7 indicator, the rotation of the follower magnet causes the pointer to linearly indicate the magnitude of the flow rate value through a cam plate.
characteristic 

M7 and M9 indicators M7 indicator A, a local indicator, corrects the linear flow rate through a cam plate. B、 The ESK type signal transmitter can also have HART protocol communication function. C、 Installation can be selected within the on-site flow indicator instrument: 5W1 angular displacement signal transmitter with (4-20) mA linear output;
ESK type signal transmitter with (4-20) mA nonlinear output without hysteresis;
◇ Upper and lower limit alarm switches.
M9 indicator A uses a pair of coupled magnets in the indicator to complete flow indication and electrical signal conversion. B、 The ESK type signal transmitter can also have HART protocol communication function. C、 Installation can be selected within the on-site flow indicator instrument: ESK type signal transmitter with (4-20) mA nonlinear output and no hysteresis;
◇ Upper and lower limit alarm switches.
Product selection code
AfterSalesService :
Key words:- Metal tube float flowmeter