Smoke monitoring sensor customized AC voltage smoke alarm 220V smoke detector
Category:
Security/Anti theft and alarm equipment/Other anti-theft and alarm equipment and systems
Model:
JTY-GD-HA801-AC
Brand:
Hongsheng High Tech
Retail Price
198.00USD
重量
kg
- Product Description
-
Description :
Product Overview
Welcome to choose our company's JTY-GD-HA801-AC photoelectric smoke detector, which works based on the principle of sensing smoke particles. Adopting unique structural design and optoelectronic signal processing technology, it has functions such as dust prevention, insect prevention, and resistance to external light interference, ensuring the stability of the product from a design perspective. This product has a good response to visible smoke generated by slow smoldering or bright burning. Suitable for smoke monitoring in indoor environments such as residential buildings, shopping malls, hotels, and warehouses.
Features
The JTY-GD-HA801-AC detector is a non coding type and can be directly connected to a DC power supply during operation. During normal operation, the work indicator light flashes. When an alarm is triggered, the alarm indicator light is on. The detector has a pair of output contacts, which close/open after an alarm. Power off/automatic reset is required after smoke-free operation. The detector adopts a positioning base and has an installation method.
● Power off/automatic reset optional
● Infrared photoelectric sensor
Intelligent logic control, filtering out various false alarms
● Normally open/normally closed (NO/NC) alarm output
The alarm sound should not be less than 75dB (note: customizable, default without sound)
● Network output/LED indication alarm
SMT process manufacturing, strong stability
Dustproof, insect proof, and anti white light interference design
Technical parameters for anti-interference RF interference (20V/m~1GHz)
Working voltage: AC110-20V
Static current: ≥ 2mA (DC24V)
Alarm current: ≥ 10mA (DC24V)
Alarm indication: red LED
Sensor: Infrared photoelectric sensor
Working temperature: -10 ℃~+50 ℃
Environmental humidity: 95% RH (no condensation phenomenon)
Anti RF interference: 10MHz~1GHz 20V/m
Alarm output: normally open/normally closed
Coverage area: When the spatial height is between 6m and 12m, one detector's
The protection area is 80m2 for general protection sites, and 60m2 for spaces with a height of less than 6m. The specific parameters should be based on the design specifications for fire automatic alarm systems GB 50116. Sensitivity level: Level 1
Dimensions: 104 (diameter) * 53mm (height)




AfterSalesService :
Key words:- Smoke monitoring sensor