Salt spray accelerated corrosion testing machine, precision salt spray testing machine, corrosion and aging resistance salt spray testing chamber
Category:
Instrumentation/Test chamber and climate environment equipment/Salt spray test instrument
Model:
HE-YW-90
Brand:
Haoen Instrument
model:
HE-YW-90
type:
Salt water spray tester
studio dimensions:
900×600×500
Is it a cross-border source of goods:
No
Retail Price
1,000.00USD
重量
kg
- Product Description
-
model HE-YW-90
type Salt water spray tester
studio dimensions 900×600×500
Is it a cross-border source of goods No
Description :
1Salt spray accelerated corrosion testing machineExecution standard:
GB/T2423.17-2008/IEC 60068-2-11-1981 Salt spray test method
ASTM.B117-2009 Salt Spray Test
JIS H8502 Salt water spray test method
GB/T10125-2012/ISO 9227-2006 Salt water spray test method
GB-T5170.8-2008 Inspection methods for environmental testing equipment for electrical and electronic products - Salt spray testing equipment
GB-T5170.11-2008 Inspection methods for corrosive gas testing equipment
GB-T10587-2006 Technical Conditions for Salt Spray Test Chamber
GJB-150.11A-2009 Equipment Environmental Test Method - Salt Spray Test
IIPrecision salt spray testing machineMain technical parameters
Specification Model
HE-YW-60
HE-YW-90
HE-YW-120
HE-YW-160
HE-YW-200
capacity
108 liters
270 liters
600 liters
960 liters
1200 liters
Inner box size (mm)
600×450×400
900×600×500
1200×1000×500
1600×1000×600
2000×1000×600
Dimensions (MM)
1070×600×1180
1410×880×1280
1900×1300×1400
2300×1300×1500
2700×1300×1500
Salt bucket capacity
15 liters
25 liters
40 liters
40 liters
40 liters
Use power supply
AC 220V 50HZ 15A
AC 220V 50HZ 15A
AC 220V 50HZ 20A
AC 220V 50HZ 20A
AC 220V 50HZ 30A
Laboratory temperature
Neutral salt water test method (NSS ACSS): 35 ℃± 1 ℃; Acid salt water test method (CASS): 50 ℃± 1 ℃
pressure tank temperature
Neutral salt water test method (NSS ACSS): 47 ℃± 1 ℃; Acid salt water test method (CASS): 63 ℃± 1 ℃
salt concentration
Neutral salt water test method (NSS ACSS): Sodium chloride concentration 5%;
Acid salt water test method (CASS): Add 0.26 grams of copper chloride (CuC12. h20) per liter of 5% sodium chloride solution
spray pressure
1.00±0.1kgf/cm2
Salt spray collection amount
1-2mL/80cm21h (collect for at least 16 hours and take the average)
relative humidity
85% H.R or above
Spray mode
Continuous spray or intermittent spray (optional)
Corrosion and aging resistance salt spray test chamberAccording to the experimental requirements, it can be divided into neutral salt spray test, acidic salt spray test, and copper accelerated acetate salt spray test.
1. Neutral salt spray test NSS test
An accelerated corrosion testing method has emerged in the current application field. 5% sodium chloride saline solution is used as the solution for spray, and the PH value of the solution is adjusted to the neutral range of 6~7). The experimental temperature is set at 35 ℃, and the settling amount of salt spray is required to be between 1-2ml/80cm2. h.
2. Acetate salt spray test ASS test
Developed on the basis of neutral salt spray testing. It is achieved by adding glacial acetic acid to a 5% sodium chloride solution, reducing the pH value of the solution to around 3 and making it acidic. The resulting salt spray also changes from neutral to acidic. Its corrosion rate is about three times faster than the neutral salt spray test.
3. Copper salt accelerated acetate salt spray test CASS test
A rapid salt spray corrosion test recently developed abroad, with a test temperature of 50 ℃. A small amount of copper salt - copper chloride - is added to the salt solution to strongly induce corrosion. Its corrosion rate is approximately 8 times that of the neutral salt spray test.