Vacuum suction blower, fully automatic feeding high-pressure fan, suction vortex air pump
Category:
Environmental Protection/Fan exhaust equipment/High pressure blower
Model:
RB-81D-1
Brand:
All wind
brand:
All wind
model:
RB-81D-1
boost:
20kpa
material:
cast aluminum
type:
high-pressure blower
Supporting motor power:
4KW
Scope of Application:
Aquaculture oxygenation
performance:
Low noise fan
Number of blades:
fifty-seven
purpose:
aquaculture
weight:
54KG
shaft power:
four
speed:
two thousand and eight hundred
Fan pressure:
high-pressure blower
airflow direction:
rotary
Turbine head material:
cast aluminum
Overall dimensions:
451*461*433
Place of Origin:
Jiangsu
manufacturer:
Quanfeng Environmental Protection Technology Co., Ltd
Retail Price
2,100.00USD
重量
kg
- Product Description
-
brand All wind
model RB-81D-1
boost 20kpa
material cast aluminum
type high-pressure blower
Supporting motor power 4KW
Scope of Application Aquaculture oxygenation
performance Low noise fan
Number of blades fifty-seven
purpose aquaculture
weight 54KG
shaft power four
speed two thousand and eight hundred
Fan pressure high-pressure blower
airflow direction rotary
Turbine head material cast aluminum
Overall dimensions 451*461*433
Place of Origin Jiangsu
manufacturer Quanfeng Environmental Protection Technology Co., Ltd
Description :
Vacuum suction blower, fully automatic feeding high-pressure fan, suction vortex air pump
Vortex high-pressure air pumpSpecifications:
Power: 0.18KW 0.4KW 0.75KW 1.1KW 1.3KW 1.5KW 2.2KW 4KW 5.5KW 7.5KW 11KW 15KW 20KW 25KW
High temperature resistant type: 0.4KW 0.75KW 1.5KW 2.2KW 3.7KW 5.5KW 7.5KW 11KW 15KW
Single phase voltage: 0.2KW, 0.4KW, 0.55KW, 0.75KW, 0.85KW, 1.1KW, 1.3KW, 2.2KW
Wind pressure: 50mbar-1010mbar
Airflow: 40m3/h-3000m3/h (for the convenience of selecting different specifications, both single-stage and two-stage models are available)
Frequency: 50HZ/60HZ Voltage: 110V-615V (universal voltage, applicable to all countries). If special voltage is required, it can be customized according to requirements
Pressure relief valve: RV-01 RV-02 (for use with)
Filter: MF08 MF10 MF12 MF16 MF20 MF32
Parameter selection:
The main parameters for selection are power, air volume and pressure (which require certain requirements for calculation), voltage, etc.
Due to the widespread use of vortex air pumps, their selection method is the same as that of high-pressure fans. Generally speaking, the following two steps need to be followed:
1. Need to determine what function of the high-pressure fan is used on site, whether it is suction or blowing, and find the corresponding pressure flow curve of the high-pressure fan; If the curve is misread, sometimes the selected product cannot be used;
2. Based on the calculated pressure and flow rate, find the working curve above the corresponding working point that satisfies both pressure and flow rates on the curve graph; Then select the high-pressure fan model based on the working curve;
As long as it is a different work site, its requirements for pressure and flow rate are different, so in order to obtain relatively accurate data, relevant calculations need to be carried out. This needs to be done by designers or consulted with companies.









Vacuum suction blower, fully automatic feeding high-pressure fan, suction vortex air pump
Characteristics:Stable flow, high efficiency, and low energy consumption: Under previous design and strict quality control, high-pressure blowers have the following performance. Low energy consumption: Therefore, any method such as blowing, spraying, or suction has its effectiveness, and high-pressure blowers have a relatively conservative design in the high-pressure range. When the usage situation changes, the high-pressure blower still operates safely. High reliability: Apart from the impeller, the high-pressure blower has no other moving parts, and the impeller is directly connected to the motor without gears or transmission belts, making it highly reliable and almost maintenance free. Easy to install: The high-pressure blower can be installed at any time in the place of use for compressed air or for vacuuming. And it can be installed in any horizontal or vertical direction. Low vibration: The mechanical precision is high, and the other components of the rotating part have undergone extremely precise balance design, testing, and calibration, so the vibration rate is very low. Low noise: Directly driven by a low-noise motor, with built-in mufflers at both the inlet and outlet to reduce noise during operation. Robust structure: The vortex high-pressure air pump body is cast with AC10 aluminum alloy, which is different from the Taiwan, China vortex air pump made of ordinary iron shell, and is more durable. No oil and gas, no pollution: When the impeller rotates, it does not come into contact with any components and is lubrication free. Space saving - sturdy design reduces space waste.
AfterSalesService :
Key words:- Vacuum suction blower
More Products