Single mode self-supporting ADSS-4B1-100 meter span AT sheathed ADSS power optical cable
Single mode self-supporting ADSS-4B1-100 meter span AT sheathed ADSS power optical cable

Single mode self-supporting ADSS-4B1-100 meter span AT sheathed ADSS power optical cable

Category:

communication/Communication cable/Other communication cables

Model:

ADSS

Brand:

Changguang Communication Technology

Retail Price

4.50USD


重量

kg

  • Product Description
  • Description :

    产品列表

    广州adss厂家武汉adss厂家

    adss结构

    adss光缆特点

    杭州adss光缆

    电缆特点

    光电复合缆

    使用范围

    型号种类

    检测报告品质保证

    合作商家

    长光通信江苏

    严格测试

      The cable diameter is small, the weight is light, the span can reach 1500M, and the additional load on the tower is low;

      High tensile strength, exceeding 90KN;

      Non metallic structure, good insulation performance, lightning protection;

      Excellent production technology, even stress distribution of aramid yarn, and excellent stress-strain performance;

      Excellent anti shooting performance;

      Excellent anti-corrosion performance;

      Can adapt to harsh weather conditions;

      Construction can be carried out without power outage, and power line failures do not affect the normal transmission of optical cables.

      ADSS optical cables are installed on high-voltage transmission lines, with a general lifespan of over 25 years. There are many factors that affect their lifespan, including:

      (1) Is there a significant gradient change in the high-voltage induced electric field near the tower? High voltage induced electric fields have strong electrical corrosion on optical cables. Generally, PE type is used for overhead power lines of 35KV and below, and AT type is used for lines of 110KV and above;

      (2) For double circuit towers, due to power outages or line modifications in the first circuit, consideration should be given when selecting hanging points;

      (3) When the line passes through a working area with salt spray and acid gas, chemical substances will corrode the outer sheath of the optical cable, damage its electrical protection sleeve, and be easily damaged by electric arcs

      The construction of ADSS optical cables is usually carried out on live line towers, and insulated endless ropes, insulated safety belts, insulated tools must be used during construction. The wind force should not exceed level 5, and a safe distance must be maintained from lines of different voltage levels, namely 35KV greater than 1.0m, 110KV greater than 1.5m, and 220KV greater than 3.0m

    AfterSalesService :

    Key words:
    • Single mode self-supporting ADSs