Underground box pump integrated anti floating integrated booster water pump station finished fire water tank supplied by the manufacturer
Underground box pump integrated anti floating integrated booster water pump station finished fire water tank supplied by the manufacturer

Underground box pump integrated anti floating integrated booster water pump station finished fire water tank supplied by the manufacturer

Category:

Security/Firefighting equipment/Fire water supply equipment

Model:

JZ-60/30-30/30-XBF

Brand:

Kanazawa

brand:

Kanazawa

model:

JZ-60/30-30/30-XBF

type:

Integrated buried box pump

material:

Prefabricated composite panel

Specifications:

15*11*3

Scope of Application:

Fire water supply

Processing & Customization:

yes

Is it imported:

No

Retail Price

35,000.00USD


重量

kg

  • Product Description
  • brand

    Kanazawa

    model

    JZ-60/30-30/30-XBF

    type

    Integrated buried box pump

    material

    Prefabricated composite panel

    Specifications

    15*11*3

    Scope of Application

    Fire water supply

    Processing & Customization

    yes

    Is it imported

    No

    Description :

    Integrated buried box pump Integrated selection of buried box pumps: The model of the fire water pump is determined based on the design flow rate and required fire water supply pressure of the fire water supply system in the engineering project. The water pump should be one in use and one as backup, and the pressure at zero flow should not exceed 140% of the system design pressure; When the system flow rate is 150% of the rated flow rate of the water pump, the pressure should not be lower than 65% of the rated pressure. The fire water tank calculates the required fire extinguishing water consumption for each individual fire water supply system based on the fire design flow rate and fire duration of each individual fire water supply system in the engineering project. When a construction project consists of multiple fire water supply systems, the total amount of water used for extinguishing a single fire is the sum of the water used for extinguishing each individual system. From this, the effective volume of the fire water tank is determined, and the size of the fire water tank can be determined based on the tank volume and the actual situation on site. The width of the main channel in the integrated pump room of the buried box pump should not be less than 1.2m, and the width of the channel in front of the electrical control cabinet should not be less than 1.5m. A 2m × 2m maintenance port should be set at the top of the pump room, which should be at least 200mm above the ground. A sliding rail type top cover should be added to the top of the maintenance port for easy opening and closing; Install escalators in the pump room for easy access; Ventilation pipes should be installed at the top of the pump room, with a height of at least 1.5m above the ground.

    AfterSalesService :

    Key words:
    • Integrated buried box pump