Working principle of sulfur dioxide sensor
Working principle of sulfur dioxide sensor

Working principle of sulfur dioxide sensor

Category:

Instrumentation/Environmental testing instruments/Other environmental testing instruments

Model:

Sulfur dioxide sensor

Brand:

middling coal

Retail Price

1,600.00USD


重量

kg

  • Product Description
  • Description :

      The mining sulfur dioxide sensor can be used in various occasions underground, continuously monitoring, displaying, and exceeding the limit alarm of sulfur dioxide content in the airflow of various places underground, and outputting signals to provide monitoring data for the monitoring substation.

      Working principle of sulfur dioxide sensor

      Under a certain control potential, oxidation reaction occurs on the working electrode of sulfur dioxide. When the point control is sufficiently positive and the catalytic activity of the electrode is high enough, the oxidation reaction proceeds quickly. The total speed of the process is determined by the diffusion step of sulfur dioxide, and the generated signal current is proportional to the concentration of sulfur dioxide.

      Working environment of sulfur dioxide sensor

      Working temperature: 20~50 degrees Celsius

      Working humidity: 15~90 [%] RH (non condensing)

      Work pressure: 91~111kPa

      Bias voltage: 0mV

      Storage time: 6 months

      Storage temperature: 0-20 degrees Celsius

      Service life: 2 years

      Characteristics and functions of sulfur dioxide sensors

      It has the characteristics of high current sensitivity, short response time, low temperature and humidity influence, good stability, and low background noise. It can not only be used to measure sulfur dioxide in the air, but also in low conductivity liquids.

      Parameters of sulfur dioxide sensor

      Large transmission distance from sensors to associated and connected devices: 2km

      The response time of the sensor should not exceed 35 seconds

      Explosion proof mark: ExibI

      Intrinsic safety parameters: Ui: 18.5 V; Ii:60 mA; Ci:0uF; Li:0mH

      zmjt063

    AfterSalesService :

    Key words:
    • Sulfur dioxide sensor