Working principle of nitrogen dioxide sensor
Working principle of nitrogen dioxide sensor

Working principle of nitrogen dioxide sensor

Category:

Instrumentation/Environmental testing instruments/Other environmental testing instruments

Model:

Nitrogen dioxide sensor

Brand:

middling coal

Retail Price

1,600.00USD


重量

kg

  • Product Description
  • Description :

      Mining nitrogen dioxide sensors can be used in various situations underground in coal mines to continuously monitor, display, and alarm for nitrogen dioxide content in the airflow of goaf, mining face, return airway, and other places underground. At the same time, they output signals to provide monitoring data for monitoring substations.

      Characteristics of nitrogen dioxide sensor products

      The whole machine adopts a new type of microcontroller and integrated digital circuit, combined with high-precision temperature components, which has the characteristics of stable performance, high measurement accuracy, fast response speed, strong anti-interference ability, simple structure, and convenient use and maintenance.

      Technical indicators of nitrogen dioxide sensor

      Working voltage: 18V DC,

      Allowable fluctuation range: (12-20) V;

      Working current ≤ 95mA;

      Large transmission distance: 2km;

      The response time should not exceed 60 seconds;

      Intrinsic safety parameters: Ui: 18.5 V; Ii:40 mA;

      Technical parameters of nitrogen dioxide sensor

      Test scope: 0~20 * 10-6

      Measurement error: 0-9 ≤± 3 * 10-6, 10-20 ≤± 4 * 10-6

      Response time: ≤ 45 seconds

      Output characteristics: Display method: 4-digit LED digital display

      Display accuracy: 1 * 10-6 Alarm range: 0~20 * 10-6 (1 * 10-6 per step)

      Alarm mode: intermittent sound (sound level>80db) intermittent flashing (red)

      Output signal: Current: DCLMA~5mA; 4mA~20mA; 200Hz~1000Hz (pulse width greater than 0.3ms)

      Output signal format can be set with one transmission distance: 2Km

      zmjt063

    AfterSalesService :

    Key words:
    • Nitrogen dioxide sensor