LDG-150 electromagnetic flowmeter price
LDG-150 electromagnetic flowmeter price

LDG-150 electromagnetic flowmeter price

Category:

Instrumentation/Flow meter/electromagnetic flowmeter

Model:

LDG-150

Brand:

Jiangsu Fenghui Instrument Co., Ltd

Retail Price

1,950.00USD


重量

kg

  • Product Description
  • Description :

      LDG-150 electromagnetic flowmeter price

      This product is a volumetric flow measurement instrument that is not affected by the temperature, viscosity, density, or conductivity (within a certain range) of the measured medium during the measurement process. Therefore, after being calibrated with water, the flowmeter can be used to measure the flow rate of other conductive liquids. Electromagnetic flow meters are widely used for flow measurement in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, municipal management, water conservancy construction, river dredging, and other fields.

      It can measure the flow rate of dirty media, corrosive media, and suspended liquid-solid two-phase flow. This is because there are no flow obstructing components inside the instrument measuring tube, and only the inner lining and electrodes of the measuring tube are in contact with the measured fluid. The material can be selected according to the properties of the measured fluid. For example, using polytetrafluoroethylene or polytetrafluoroethylene as lining can measure various corrosive media such as acids, alkalis, salts, etc; The use of wear-resistant rubber as an inner lining is particularly suitable for measuring liquid-solid two-phase flows such as slurry and cement slurry with solid particles and high wear, as well as various suspended liquids such as fibrous liquids and pulp.

      1、 Category:

      Electromagnetic flow meters consist of sensors and intelligent signal converters, which can be divided into two types of structures based on the assembly form of the converter and sensor: integrated and separated.

      Integrated: The converter and sensor are directly assembled as a whole and cannot be separated. Commonly used in sites with good environmental conditions.

      Split type: The converter is composed of a dedicated cable and a sensor to form a product, with the sensor installed on site and the converter installed in a location with better conditions. Commonly used in sites with poor environmental conditions, such as underground wells, high temperatures, and places that are difficult for personnel to reach.

      LDG-150 electromagnetic flowmeter price

      2、 Characteristics

      1. The range of electromagnetic flowmeter is wide.

      2. In addition to measuring the volumetric flow rate of general conductive liquids, electromagnetic flow meters can also be used to measure strongly corrosive liquids such as strong acids and alkalis, as well as slurries, slurries, and pulp.

      3. A bidirectional measurement system that can measure both forward and reverse flow rates.

      4. The measurement results of electromagnetic flowmeter are independent of physical parameters such as pressure, temperature, density, viscosity, conductivity, and are not affected by the environment.

      5. Rubber electromagnetic flowmeter has reliable performance, high accuracy, low power consumption, stable zero point, and convenient parameter setting. Click on the Chinese display LCD to show accumulated flow, instantaneous flow, flow rate, flow percentage, etc.

      LDG-150 electromagnetic flowmeter price

      3、 Characteristics:

      The sensor has a simple structure, no throttling device, no blockage, and is suitable for measuring liquids containing solid particles, fibers, and suspended solids.

      There are multiple options for liquid contact materials, which can be used for measuring various corrosive liquids.

      It can be installed horizontally, vertically, or diagonally, as long as the measuring tube is filled with liquid and free of bubbles.

      The measurement range is wide, with a range ratio of 100:1, and the range can be modified.

      On site zero calibration is possible without affecting measurement accuracy.

      Low power consumption, less than 7W.

      On site LCD displays instantaneous flow rate, cumulative flow rate, flow percentage, fluid flow rate, and fault alarm.

      The Chinese menu allows for parameter viewing and modification according to prompts, and the four button functions are set by the software at any time, making it easy to learn.

      Fault self diagnosis can achieve air traffic control judgment alarm, excitation fault alarm, over range alarm, and output signal fault alarm.

      It can accumulate forward traffic, reverse traffic, and bidirectional traffic difference.

      Automatic conversion of measurement units and decimal places.

      High explosion-proof level, explosion-proof mark Exd (ia) iaq Ⅱ CT6.

      Multiple signal output options include 4-20mA, 0-1kHz, HART, RS485, etc.

      Customizable unlined electromagnetic flowmeter.

      One click restore factory parameter settings.

    AfterSalesService :

    Key words:
    • LDG electromagnetic flowmeter