  • Description :

      Remote transmission LDE-450 electromagnetic flowmeter

      This product consists of two parts: sensors and converters. It works based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. It is an inductive instrument for measuring the volumetric flow rate of conductive media.

      1、 Characteristics:

      1. Three electrode structure safety grounding

      2. Electrode materials: Hastelloy C alloy, titanium, tantalum

      3. PTFE lining resistant to strong acids and alkalis

      4. Stainless steel casing extends lifespan

      5. Density conversion function, easy to calculate mass

      Remote transmission LDE-450 electromagnetic flowmeter

      2、 Technical parameters:

      Accuracy level: ± 0.5%, ± 1%

      Lining materials: polyurethane, chloroprene rubber, polytetrafluoroethylene, etc

      Electrode materials: stainless steel, Hastelloy, titanium, platinum iridium alloy, etc

      Connection methods: flange clamping, flange connection, etc

      Medium temperature: 0 ℃~70 ℃, 0 ℃~130 ℃ (0 ℃~180 ℃)

      Nominal pressure: 1.0Mpa~32 Mpa

      Protection level: IP65, IP68

      Explosion proof mark: ExibBT4

      3、 Installation precautions:

      Avoid lightning strikes

      Ensure ventilation and dryness, avoid excessive temperature, humidity, and corrosive gases

      Electromagnetic flow meters installed outdoors should have shading and rainproof measures, and avoid direct sunlight exposure

      4、 Daily maintenance:

      Regularly check whether the electromagnetic flowmeter converter is immersed in water, damp, or corroded

      Regularly clean the electrodes and measuring tubes, and do not damage the electrodes and lining during cleaning

      Regularly check whether the aging and contact degree of the connecting cables are intact

    AfterSalesService :

    Key words: