Carbon steel LDE-300 electromagnetic flowmeter
The main structure of this product consists of a magnetic circuit system, measuring conduit, electrode, housing, lining, and converter. Advantages include: measurement is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity; There are also advantages such as unobstructed flow components inside the measuring tube, no pressure loss, and high measurement accuracy.
1、 Performance characteristics:
The instrument structure is simple, reliable, without moving parts, and has a long working life.
No flow blocking components, no pressure loss or fluid blockage.
No mechanical inertia, fast response, good stability, can be applied to automatic detection, adjustment, and program control systems.
The measurement accuracy is not affected by the type of measured medium and its physical parameters such as temperature, viscosity, density, pressure, etc.
Different combinations of PTFE or rubber lining materials and electrode materials such as Hc, Hb, 316L, Ti can adapt to the needs of different media.
There are various flow meter models available, including pipeline type and plug-in type.
Using EEPROM memory, the storage of measurement and operation data ensures safety and reliability.
It has two types: integrated and separated.
High definition LCD backlit display.

Carbon steel LDE-300 electromagnetic flowmeter
2、 Installation:
The selection of installation site for large water pipe flow meters is a factor that must be considered.
The protection level of the sensor housing is usually IP68 (immersion level specified in GB4208), and the installation site has the following requirements:
1) When measuring mixed phase fluids, choose a location that will not cause phase separation; When measuring two-component liquids, avoid placing them downstream before mixing evenly. When measuring chemical reaction pipelines, they should be placed downstream of the fully reacted section;
2) Try to avoid negative pressure inside the measuring tube as much as possible;
3) Avoid attachments such as large motors and transformers to prevent electromagnetic interference;
4) Choose a location with low vibration, especially for integrated instruments;
5) Try to avoid high concentrations of corrosive gases in the surrounding environment as much as possible;
6) Places that are easy to implement separate grounding for sensors;
7) The ambient temperature is within the range of -25/-10 to 50/600 ° C, and the temperature of the integrated structure is also limited by electronic components, with a narrower range;
8) Try to avoid direct sunlight as much as possible
9) The relative humidity of the environment should be within the range of 10% to 90%, and rainwater immersion should also be avoided.
3、 Ordering instructions:
The quality of the product during use is directly related to the selection of the initial order
The following parameters are required for ordering and procurement:
What medium does the electromagnetic flowmeter measure.
What is the working pressure of the pipeline
What is the working temperature of the pipeline
4. Flow range during work
5. What is the diameter of the pipeline and what material is the pipeline itself made of
Only by providing the above parameters can we ensure the accuracy and stability of the electromagnetic flowmeter we produce when you use it