LDG-DN100 electromagnetic flowmeter
LDG-DN100 electromagnetic flowmeter

LDG-DN100 electromagnetic flowmeter

Category:

Instrumentation/Flow meter/electromagnetic flowmeter

Model:

LDG-100

Brand:

Jiangsu Fenghui Instrument Co., Ltd

Retail Price

1,850.00USD


重量

kg

  • Product Description
  • Description :

      LDG-DN100 electromagnetic flowmeter

      This product is mainly used to measure the volumetric flow rate of conductive liquids and slurries in closed pipelines. Such as water, sewage, mud, pulp, various acids, alkalis, salt solutions, food slurries, etc., are widely used in industries such as petroleum, chemical, metallurgical, textile, food, pharmaceutical, papermaking, as well as environmental protection, municipal management, water conservancy construction, etc. to measure high temperature, high humidity, and difficult to observe environments.

      1、 Technical parameters:

      Accuracy level: ± 0.5%, ± 1%

      Lining materials: polyurethane, chloroprene rubber, polytetrafluoroethylene, etc

      Electrode materials: stainless steel, Hastelloy, titanium, platinum iridium alloy, etc

      Connection methods: flange clamping, flange connection, etc

      Medium temperature: 0 ℃~70 ℃, 0 ℃~130 ℃ (0 ℃~180 ℃)

      Nominal pressure: 1.0Mpa~32 Mpa

      Protection level: IP65, IP68

      Explosion proof mark: ExibBT4

      Working voltage: 220VAC, 24VDC

      LDG-DN100 electromagnetic flowmeter

      2、 Selection:

      1. Determination of applicable traffic range. The selection of instrument diameter is determined based on the flow range. For electromagnetic flow meters, they are generally selected in situations where the flow signal is strong and the instrument can work stably for a long time. We suggest that you choose your instrument caliber based on the flow rate flow comparison table (see table below) and refer to the actual operating conditions. We recommend a flow rate range of 1-3m/s, which is beneficial for the instrument to be in a suitable state.

      2. Selection of lining and electrodes. In addition to determining the diameter and flow range, electromagnetic flowmeters also need to choose relevant conditions such as sensor lining and matching electrodes to improve their economic applicability. The design unit can choose different linings, electrodes, etc. according to the different media of different users

      3. Pressure and usage situation. In addition to determining the above conditions, the electromagnetic flowmeter should also improve the selection of operating pressure, installation form, shell protection level, explosion-proof requirements, output configuration, and other usage conditions and conditions. The integrated type is suitable for indoor environments with good performance, while the split type is suitable for situations where the sensor is used in harsh environments, with large pipeline vibrations and high temperature of the measured medium. Please choose according to the instrument model markings.

      3、 Product features:

      1. Suitable for volumetric flow measurement of conductive fluids with conductivity greater than 5 ц s/cm;

      2. There are no active or obstructed components inside the measuring tube, and the pressure loss is small;

      3. Lining and electrodes with different materials have good anti-corrosion performance;

      4. Not affected by medium, density, viscosity, temperature, pressure, and conductivity;

      5. Low frequency rectangular wave excitation, less susceptible to interference, stable and reliable;

      6. The converter has low energy consumption, simple and convenient installation, and users do not need to debug.

    AfterSalesService :