Description :
This product is a flowmeter that integrates intelligence, small and lightweight design, multifunctionality, high precision, and high reliability.
1、 Technical features:
1. Suitable for liquid flow detection with conductivity greater than 5 μ s/cm. Changes in conductivity do not affect performance changes
2. Electromagnetic flow meters have long-term high measurement accuracy and are actually not affected by fluid physical properties
3. Easy to put into operation, the flowmeter is automatically set within the range of 0-10m/s, without the need to change the measurement range
4. All components in contact with the tested medium have good corrosion resistance and wear resistance, with a wide range of applications
5. There are no movable parts or flow blocking components in the pipeline, and there is almost no additional pressure loss during measurement
6. The measurement results are independent of physical parameters such as flow velocity distribution, fluid pressure, temperature, density, viscosity, etc
7. On site, the range can be modified online according to the actual needs of the user
8. High definition backlit LCD display, fully Chinese menu operation, easy to use, simple to operate, easy to learn and understand
9. All digital processing, strong anti-interference ability, reliable measurement, high accuracy, flow measurement range can reach 150:1
10. There are three integrators inside that can display the forward cumulative and reverse cumulative amounts, as well as the difference cumulative amount. There is also a non power down clock inside that can record the power down time
11. Capable of outputting communication signals such as 4-20mA, RS485, RS232, Hart, and Modbus
12. Equipped with self checking and self judging functions
13. The electromagnetic flowmeter is easy to use. After installation, simply connect the power supply and no other operation is required to output standard signals, making it convenient for non professionals to use.

2、 Technical parameters:
1. Measurable pipe diameter: Pipeline PTFE lining: DN10~DN600 Pipeline rubber lining: DN40~DN1200 Note: Special specifications can be customized
2. Accuracy level: Pipeline type: 0.5 level, 1.0 level
3. Temperature of the tested medium:
Ordinary rubber lining: -20 to+60 ℃; High temperature rubber lining: -20 to+90 ℃
PTFE lining: -30 to+100 ℃; High temperature PTFE lining: -30 to+180 ℃
4. Rated working pressure:
DN10—DN65:2.5MPa
DN80—DN150:1.6MPa
DN200—DN1200:1.0MPa
5. Output signal and load resistance: 4-20mADC, 0-500 Ω
6. Electrode materials: including molybdenum stainless steel, titanium (Ti), tantalum (Ta), Hastelloy (HB), etc
7. Protection level: Submersible type: IP68, others: IP65
8. Power supply: 220VAC
9. Straight pipe length: Pipeline type: upstream ≥ 5DN, downstream ≥ 2DN
10. Connection method:
The electromagnetic flowmeter is installed in a pipeline manner, and flange connections are used between it and the piping. The size of the vertical connection should comply with the provisions of GB9119-88.
3、 Selection of installation location:
1. The flow direction indicator on the sensor must be consistent with the direction of the measured medium flow inside the pipeline.
2. The installation position must ensure that the measuring tube is filled with the measured medium.
3. Choose a location with smaller fluid flow impulse, which should be away from the pump and local resistance components (valves, elbows, etc.)
4. When measuring two-phase fluids, a location that is not prone to phase separation should be selected.
5. Installation in areas with negative pressure inside the pipe should be avoided as much as possible.
6. When the measured medium easily causes adhesion and scaling on the inner wall of the electrode and measuring tube, it is recommended that the flow velocity inside the measuring tube should not be less than 2m/s.

AfterSalesService :
Key words:- Remote transmission DN125 electromagnetic flowmeter