Large caliber DN250 electromagnetic flowmeter DN250 pipeline electromagnetic flowmeter
Large caliber DN250 electromagnetic flowmeter DN250 pipeline electromagnetic flowmeter

Large caliber DN250 electromagnetic flowmeter DN250 pipeline electromagnetic flowmeter

Category:

Instrumentation/Flow meter/electromagnetic flowmeter

Model:

LDE-250

Brand:

Jiangsu Fenghui Instrument Co., Ltd

Retail Price

2,500.00USD


重量

kg

  • Product Description
  • Description :

      This product is a flowmeter that integrates intelligence, small and lightweight design, multifunctionality, high precision, and high reliability.

      1、 Technical features:

      1. Suitable for liquid flow detection with conductivity greater than 5 μ s/cm. Changes in conductivity do not affect performance changes

      2. Electromagnetic flow meters have long-term high measurement accuracy and are actually not affected by fluid physical properties

      3. Easy to put into operation, the flowmeter is automatically set within the range of 0-10m/s, without the need to change the measurement range

      4. All components in contact with the tested medium have good corrosion resistance and wear resistance, with a wide range of applications

      5. There are no movable parts or flow blocking components in the pipeline, and there is almost no additional pressure loss during measurement

      6. The measurement results are independent of physical parameters such as flow velocity distribution, fluid pressure, temperature, density, viscosity, etc

      7. On site, the range can be modified online according to the actual needs of the user

      8. High definition backlit LCD display, fully Chinese menu operation, easy to use, simple to operate, easy to learn and understand

      9. All digital processing, strong anti-interference ability, reliable measurement, high accuracy, flow measurement range can reach 150:1

      2、 Technical parameters:

      1. Measurable pipe diameter: Pipeline PTFE lining: DN10~DN600 Pipeline rubber lining: DN40~DN1200 Note: Special specifications can be customized

      2. Accuracy level: Pipeline type: 0.5 level, 1.0 level

      3. Temperature of the tested medium:

      Ordinary rubber lining: -20 to+60 ℃; High temperature rubber lining: -20 to+90 ℃

      PTFE lining: -30 to+100 ℃; High temperature PTFE lining: -30 to+180 ℃

      4. Rated working pressure:

      DN10—DN65:2.5MPa

      DN80—DN150:1.6MPa

      DN200—DN1200:1.0MPa

      5. Output signal and load resistance: 4-20mADC, 0-500 Ω

      3、 Installation:

      ⑴ Try to avoid ferromagnetic objects, high radio frequency, strong vibration interference sources, and equipment with strong electromagnetic fields (such as high-power motors, large transformers, etc.) to avoid magnetic fields affecting the working magnetic field and flow signal of the sensor.

      ⑵ It should be installed in a dry and ventilated place as much as possible, and should not be installed in damp or water prone areas.

      ⑶ Avoid direct sunlight and rain as much as possible, and the ambient temperature should be between -20 and 60 ℃ with a relative humidity of less than 95%.

      ⑷ Choose a place that is easy to maintain and move around.

      ⑸ The flowmeter should be installed at the rear end of the water pump and must not be installed on the suction side; The valve should be installed on the downstream side of the flow.

    AfterSalesService :

    Key words:
    • Large caliber DN250 electromagnetic flowmeter