LUX-32 Spiral Vortex Flow Meter Direct Sales
LUX-32 Spiral Vortex Flow Meter Direct Sales

LUX-32 Spiral Vortex Flow Meter Direct Sales

Category:

Instrumentation/Flow meter/flowmeter

Model:

LUX-32

Brand:

Jiangsu Fenghui Instrument Co., Ltd

Retail Price

3,000.00USD


重量

kg

  • Product Description
  • Description :

      This product is widely used in industries such as kerosene, chemical industry, power sector, metallurgical manufacturing, industrial boilers, etc. It is a gas flow detection instrument for measuring the volume flow rate and total amount of low viscosity gases in natural gas and gas pressure regulating station pipelines, as well as gas thermal measurement.

      1、 Structure:

      The flowmeter structure consists of five major components

      Flow detection component A

      A1 vortex generator A2 shell A3 vortex flow sensor A4 vortex rectifier

      Flow integrator B

      B1 shell B2 display window B3 output interface

      Temperature sensor component C

      Pressure sensor component D

      Connecting body E

      2、 Technical parameters:

      1. The flow range is the flow range verified at the time of product delivery (at room temperature and atmospheric pressure, the medium is air 1.205Kg/m3); As the pressure increases, the flow range also expands.

      2. Standard state conditions; P=101.325kPa,T=293.15K。

      3. Usage conditions: Environmental temperature: -30~+60 ℃, medium temperature: -20~+80 ℃, relative temperature: 5%~95%, atmospheric pressure: 86kPa~106kPa.

      4. Electrical performance indicators

      Working power supply: external power supply:+24VDC, internal power supply: 3.6V lithium battery, overall energy consumption: external power supply,<1W, internal power supply,<0.3MW, lithium battery can be used for more than two years.

      Output mode: frequency signal, 4-20mA signal, RS485 communication (capable of transmitting temperature, pressure, instantaneous flow rate, and cumulative flow rate parameters).

      3、 Installation:

      1. Sensors can be installed in vertical, horizontal, or any inclined position according to the flow direction indicator;

      2. When the pipeline is long or close to the vibration source, supports should be installed upstream and downstream of the flowmeter to eliminate the impact of pipeline vibration;

      3. The installation location of the sensor should have sufficient space for the inspection and maintenance of the flowmeter, and should meet the environmental requirements of the flowmeter;

      4. Avoid interference from strong external magnetic fields;

      5. When installed and used outdoors, there should be a cover to avoid direct sunlight and rainwater erosion, which may affect the service life of the instrument;

      6. When conducting pipeline pressure testing, attention should be paid to the pressure measurement range of the pressure sensor equipped on the intelligent flowmeter to avoid damaging the pressure sensor due to overpressure.

    AfterSalesService :

    Key words:
    • LUX-32 Spiral Vortex Flow Meter