DN150 spiral vortex flowmeter
Category:
Instrumentation/Flow meter/flowmeter
Model:
LUX-150
Brand:
Jiangsu Fenghui Instrument Co., Ltd
Retail Price
5,300.00USD
重量
kg
- Product Description
-
Description :
This product can work simultaneously with external power supply and battery power supply. Under normal circumstances, it is powered by 24V. In case of emergency or power outage, the built-in battery can continue to supply power, ensuring the normal recording and monitoring of data.
1、 Technical parameters
Nominal diameter: DN15-DN200 (diameters larger than DN1600 can also be used)
Tested media: natural gas, air, nitrogen, biogas, etc
Basic error: ± 1.0%, ± 1.5%,
Work pressure: ≤ 6.3 MPa
Temperature of the tested medium: < 80 ℃
Requirements for straight pipe section: upstream 0-5D, downstream 0-3D
Power supply: lithium battery and 24V DC
Display: 8-bit LCD displays instantaneous flow and cumulative flow
Output signal: (1) 4-20mA DC flow signal (2) HART protocol compliant output signal
Explosion proof performance: intrinsic safety type IbIICT5
Protection performance: IP65

2、 Characteristics
No mechanical movable parts, corrosion-resistant, stable and reliable, long service life, long-term operation without special maintenance;
Using 16 bit computer chips, high integration, small size, good performance, and strong overall functionality;
The intelligent flowmeter integrates a flow probe, microprocessor, pressure, and temperature sensors, and adopts a built-in combination to make the structure more compact. It can directly measure the flow rate, pressure, and temperature of the fluid, and automatically track compensation and compression factor correction in real time;
The use of dual detection technology can effectively improve the strength of detection signals and suppress interference caused by pipeline vibration;
Adopting a Chinese character dot matrix display screen, it has a large number of digits for intuitive and convenient reading. It can directly display the volume flow rate under working conditions, the volume flow rate under standard conditions, the total amount, as well as parameters such as medium pressure and temperature.
3、 Precautions
1. The directional signs can be installed in vertical, horizontal, or any inclined position.
2. When the pipeline is long or close to the vibration source, supports should be installed upstream and downstream of the flowmeter to eliminate the impact of pipeline vibration.
3. The installation location of the vortex flowmeter should have sufficient space for inspection and maintenance of the flowmeter, and should meet the environmental requirements of the flowmeter.
4. Avoid interference from strong external magnetic fields.
5. When installed and used outdoors, there should be a cover to avoid direct sunlight and rainwater erosion, which may affect the service life of the instrument.
6. During pipeline pressure testing, attention should be paid to the pressure measurement range of the pressure sensor equipped with the intelligent vortex flowmeter to avoid damage to the pressure sensor due to overpressure.

AfterSalesService :
Key words:- DN150 spiral vortex flowmeter