Description of DN32 electromagnetic flowmeter
Category:
Instrumentation/Flow meter/electromagnetic flowmeter
Model:
LDE-32
Brand:
Jiangsu Fenghui Instrument Co., Ltd
Retail Price
1,600.00USD
重量
kg
- Product Description
-
Description :
1. Overview:
This product can measure the flow rate of dirty media, corrosive media, and suspended liquid-solid two-phase flow. This is because there are no flow obstructing components inside the instrument measuring tube, and only the inner lining and electrodes of the measuring tube are in contact with the measured fluid. The material can be selected according to the properties of the measured fluid. For example, using polytetrafluoroethylene or polytetrafluoroethylene as lining can measure various corrosive media such as acids, alkalis, salts, etc; The use of wear-resistant rubber as an inner lining is particularly suitable for measuring liquid-solid two-phase flows such as slurry and cement slurry with solid particles and high wear, as well as various suspended liquids such as fibrous liquids and pulp.
2、 Characteristics:
1. The range of electromagnetic flowmeter is wide.
2. In addition to measuring the volumetric flow rate of general conductive liquids, electromagnetic flow meters can also be used to measure strongly corrosive liquids such as strong acids and alkalis, as well as slurries, slurries, and pulp.
3. A bidirectional measurement system that can measure both forward and reverse flow rates.
4. The measurement results of electromagnetic flowmeter are independent of physical parameters such as pressure, temperature, density, viscosity, conductivity, and are not affected by the environment.
5. Electromagnetic flowmeter has reliable performance, high accuracy, low power consumption, stable zero point, and convenient parameter setting. Click on the Chinese display LCD to show accumulated flow, instantaneous flow, flow rate, flow percentage, etc.

3、 Technical parameters:
Nominal diameter (mm) (special specifications can be customized)
Pipeline type PTFE lining: DN10~DN600
Pipeline rubber lining: DN40~DN2200
Flow direction: positive, negative, net flow
Range ratio: 150:1
Repetitive error: ± 0.1% of the measured value
Accuracy level: Pipeline type: 0.5 level, 1.0 level
Temperature of the tested medium: ordinary rubber lining: -20 to+60 ℃; High temperature rubber lining: -20 to+90 ℃
PTFE lining: -30 to+100 ℃; High temperature PTFE lining: -20 to+180 ℃
Rated working pressure: (high pressure can be customized) DN10- DN150: ≤ 1.6MPa; DN200-DN350:≤1.0MPa
DN400-DN1000:≤0.6MPa; DN450-DN2200:≤0.25MPa
Flow velocity range: 0.1-15m/s
4、 Installation:
1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields (such as large motors, transformers, etc.) to prevent the magnetic field from affecting the working magnetic field and flow signal of the sensor.
2. It should be installed in a dry and ventilated place as much as possible, avoiding direct sunlight and rain. The ambient temperature should be between -20 and+60 ℃, and the relative humidity should be less than 85%.
3. There should be ample space around the flowmeter for easy installation and maintenance.

AfterSalesService :