German Detu flue gas analyzer testo 350 imported portable flue gas analyzer testo 350 comprehensive flue gas analyzer
German Detu flue gas analyzer testo 350 imported portable flue gas analyzer testo 350 comprehensive flue gas analyzer

German Detu flue gas analyzer testo 350 imported portable flue gas analyzer testo 350 comprehensive flue gas analyzer

Category:

Instrumentation/Gas analyzer/flue gas analyzer

Model:

testo 350

Brand:

German Detu

model:

testo 350

resolution:

0.1ppm

measurement object:

O2 CO NO NO2 SO2 NOx H2S CO2

measurement range:

0-10000PPM

power supply voltage:

two hundred and twenty

type:

portable

display mode:

digital display

structural style :

Analysis box+handheld device

Processing & Customization:

No

gas flow rate:

one thousand

Specifications:

Original imported

manufacturer:

German Detu

Retail Price

65,800.00USD


重量

kg

  • Product Description
  • model

    testo 350

    resolution

    0.1ppm

    measurement object

    O2 CO NO NO2 SO2 NOx H2S CO2

    measurement range

    0-10000PPM

    power supply voltage

    two hundred and twenty

    type

    portable

    display mode

    digital display

    structural style

    Analysis box+handheld device

    Processing & Customization

    No

    gas flow rate

    one thousand

    Specifications

    Original imported

    manufacturer

    German Detu

    Description :

      German Detu flue gas analyzer testo 350 imported portable flue gas analyzer testo 350 comprehensive flue gas analyzer

      German Detu flue gas analyzer

      RCHB123: I3345O14433 Same V

    The first half of your life may belong to someone else

    Living in someone else's perception

    Give yourself back the rest of your life

    Follow the voice within you

    Product Introduction

      Detu's measurement technology experts have developed the portable smoke analyzer testo 350 for YE, which has effective preset functions to guide users to smoothly conduct YE smoke analysis. Compared with the previous flue gas analyzer testo340, testo 350 can also measure other parameters such as CO2-IR (infrared), CxHy, and H2S, and can also be equipped with commonly used gas preparation devices.

    List of advantages:

      Analysis box - industrial standard, sturdy and reliable

      handheld controller-compact and convenient

      Easy to maintain and upkeep inspection port

      Thermal isolated sensor chamber

      Gas sensors are easy to replace

      Automatic monitoring condenser tank

      Color graphic large screen display and preset dedicated menu

    testo 350 Enhanced - Handheld Device

      ● Operation and Display

      All settings can be operated through cursor keys

      New color graphic display screen for displaying measurement values

      ● Can be connected to a PC through a USB interface

      Can be connected to the analysis box through the Testo data bus cable

      ● Built in storage function (250000 measurement values)

    testo 350Enhanced - Handheld Device Connection Port

      ● Includes all sensors and measurement technologies, etc.:

      → Gas sensor

      → Optional Peltier gas preprocessor

      → Air pump and cleaning pump

      → Condensation tank

      ● Operated through a handheld device or PC/laptop

      ● Built in storage function (250000 measurement values)

      Testeo 350 Enhanced - Analysis Box Connection Port

    Instrument options:

    testo350 At least two gas sensors need to be configured to function properly. Up to 6 sensors can be upgraded:

    optional CO(H2 Compensation sensor, 0-10000 ppm, resolution 1 ppm

    optional COlow(H2 Compensation sensor, 0-500 ppm, resolution 0.1 ppm

    optional NOSensor, 0-4000 ppm, resolution 1ppm

    optional NOlowSensor, 0-300 ppm, resolution 0.1ppm

    optional NO2 Sensor, 0-500 ppm, resolution 0.1 ppm

    optional SO2 Sensor, 0-5000 ppm, resolution 1ppm

    optional CO2 (NDIR)Sensor, 0-50 Vol%, resolution 0.01 Vol%, infrared measurement principle, including absolute pressure measurement, condensate tank liquid level monitoring, and CO2 Absorption filter. If the measurement duration is greater than 2 hours, it is recommended to use a Peltier gas pretreatment module

    optional CxHy Sensors, methane 100-40000 ppm, propane 100-21000 ppm, butane 100-18000 ppm, resolution 10 ppm. Factory set to methane

    optional H2SSensor, 0-300 ppm, resolution 0.1ppm

    Optional gas pretreatment module, including peristaltic pump, can automatically drain condensate water

    Optional fresh air valve for long-term measurement, including 5x range extension function for all sensors. If the measurement duration is greater than 2 hours, it is recommended to use a Peltier gas pretreatment module

    Optional single slot range extension, with optional expansion factors (0, 2, 5, 10, 20, 40) (Multiple times)

    optional 11V-40VDC input

    Optional special air pump for long-term measurement, with extended warranty. For measurements lasting more than 2 hours, it is recommended to additionally select a Peltier gas pretreatment module

    Optional automatic zeroing pressure sensor for continuous measurement of flow rate/differential pressure

    Technical Specifications:testo 350 Technical parameters of handheld device

    Storage temperature: -20~+50 ° C

    Operating temperature: -5~+45 ° C

    Weight: 440 g

    Size: 88 x 38 x 220 mm

    Memory: 2 MB (250000 measurement values)

    Battery Type: Lithium Battery

    Battery life: 5 hours (without wireless connection)

    Protection level: IP 40

    Range: -200~+1370 ° C

    Accuracy:

      ±0.4 °C (-100 ~ +200 °C )

      ±1 °C (-100 ~ +100.1 °C )

      ±1 °C (+200.1 ~ +1370 °C )

      Resolution: 0.1 ° C

    Temperature measurement environment temperature probe: range: -20~+50 ° C, accuracy: ± 0.2 ° C; resolution: 0.1 ℃

    Flow rate: range 0~+40 m/s; Resolution: 0.1 m/s

    Dew point calculation of flue gas: range 0~+99.9 ° Ctd; Resolution: 0.1 ° Ctd

    1: Electrochemical O2 measurement: Range: 0~+25 vol.% O2;

    Accuracy: ± 0.8% of full scale;

    Resolution: 0.01 vol.% O2

    2:Electrochemical CO (H2 compensation) measurement: Range: 0~+10000 ppm CO;

    Accuracy:

    ± 5% measurement value (+200~+2000 ppm CO)

    ± 10% measurement value (+2001~+10000 ppm CO)

    ± 10 ppm CO(0 ~ +199 ppm CO)

    Resolution: 1 ppm CO

    3: Electrochemical COlow (H2 compensation) measurement:Range: 0~+500 ppm CO

    Accuracy:

    ± 5% measurement value (+40~+500 ppm CO)

    ± 2 ppm CO(0 ~ +39.9 ppm CO)

    Resolution: 0.1 ppm CO

    4:Electrochemical NO measurement: Range 0~+4000 ppm NO

    Accuracy:

    ± 5% measurement value (+100~+4000 ppm NO)

    ± 5 ppm NO(0 ~ +99 ppm NO)

    Resolution: 1 ppm NO

    5:Electrochemical NOlow measurement: Range: 0~+300 ppm NO

    Accuracy:

    ± 5% measurement value (+40~+300 ppm NO)

    ± 2 ppm NO(0 ~ +39.9 ppm NO)

    Resolution: 0.1 ppm NO

    6:Electrochemical NO2 measurement: Range: 0~+500 ppm NO2

    Accuracy:

    ± 5% measurement value (+100~+500 ppm NO2)

    ± 5 ppm NO2(0 ~ +99.9 ppm NO2)

    Resolution: 0.1 ppm NO2

    7:Electrochemical SO2 measurement: Range: 0~+5000 ppm SO2

    Accuracy:

      ± 5% measurement value (+100~+5000 ppm SO2)

      ± 5 ppm SO2(0 ~ +99 ppm SO2)

      Resolution: 1 ppm SO2

    8:Infrared CO2 measurement: Range: 0~+50 vol.% CO2

    Accuracy:

      ± 0.3 vol.% CO2+1% measured value (0~25 vol.% CO2)

      ± 0.5 vol.% CO2+1.5% measured value (>25~50 vol.% CO2)

      Resolution:

      0.01 Vol.% CO2(0 ~ 25 Vol.% CO2)

      0.1 Vol.% CO2(> 25 Vol.% CO2)

      9:Electrochemical H2S measurement

    Range: 0~+300 ppm H2S

    Accuracy:

      ± 0.5% measurement value (+40~+300 ppm)

      ± 2 ppm(0 ~ +39.9 ppm)

      Resolution: 0.1 ppm

    Technical Specifications

      

      

      shell

      

      ABS

      

      Protection level

      

      IP40

      

      warranty

      

      1 year

      

      Battery Type

      

      lithium battery

      

      battery life

      

      5 hours

      

      power supply

      

      AC 100V-240V (50-60 Hz)

      

      DC voltage input

      

      11V - 40V

      

      Trigger signal input

      

      Voltage 5-12 V (rising or falling) Pulse frequency>1 s Load: 5 V/max, 5 mA, 12 V/max.40 mA

      

      Maximum humidity load

      

      Dew point temperature at the inlet of the analyzer flue gas+70 ℃

      

      Dew point calculation

      

      0 °Ctd; 99 °Ctd

      

      The most D dust load

      

      20 g/m3 smoke and dust volume

      

      The lowest negative pressure of smoke gas

      

      -300 mbar

      

      The maximum positive pressure of flue gas

      

      50 mbar

      

      Hose length

      

      Maximum length of 16.2 m (connected by 5 extension hoses)

      

      pump flow rate

      

      1 liter/minute, with flow monitoring

      

      The most D-type memory

      

      250000 readings

      

      storage temperature

      

      -20 ~ +50 °C

      

      weight

      

      4800 g

      

      diameter

      

      330 x 128 x 438 mm

      

      Operating temperature

      

      -5 ~ +45 °C

      

    AfterSalesService :

    Key words:
    • German Detu flue gas analyzer