Total Phosphorus Online Automatic Monitoring Instrument Total Phosphorus Total Nitrogen Automatic Monitoring Instrument Total Phosphorus TP Online Automatic Monitoring Instrument COD Sewage Treatment Plant Online Water Quality Monitoring Instrument
Category:
Environmental Protection/Analytical instruments/Water quality online monitoring system
Model:
RC-601
Brand:
Thermal Holding Environmental Protection
model:
RC-601
Working Voltage:
twenty-four
measurement accuracy:
≤±3%
structural style :
online
Temperature control range:
5-28℃
Product Type:
online
Processing & Customization:
yes
power:
one hundred and fifty
weight:
seventy
Scope of Application:
601*450*302
Place of Origin:
Qingdao
manufacturer:
Qingdao Hot Holding Environmental Protection
Retail Price
17,800.00USD
重量
kg
- Product Description
-
model RC-601
Working Voltage twenty-four
measurement accuracy ≤±3%
structural style online
Temperature control range 5-28℃
Product Type online
Processing & Customization yes
power one hundred and fifty
weight seventy
Scope of Application 601*450*302
Place of Origin Qingdao
manufacturer Qingdao Hot Holding Environmental Protection
Description :
Total Phosphorus Online Automatic Monitor Total Phosphorus and Nitrogen Automatic Monitor COD Sewage Treatment Plant Online Water Quality Monitor
Total Phosphorus (TP) Online Automatic Monitoring Instrument
Total Phosphorus Online Automatic Monitor Total Phosphorus Total Nitrogen Automatic Monitor Total Phosphorus (TP) Online Automatic Monitor COD Sewage Treatment Plant Online Water Quality Monitor
RCHB123: I3345OI4433 Same V

Total Phosphorus (TP) Online Automatic Monitoring Instrument
1、 Principle
Under high temperature and high pressure conditions, the sample was digested with potassium urate, and all phosphorus containing compounds in the sample were converted
For orthophosphate (this step is not required for measuring orthophosphate). In a 5% -8% Xiao acid solution, orthophosphate
Salt forms soluble phosphorus vanadium molybdenum yellow complexes with ammonium metavanadate and ammonium molybdate, which are measured at specific wavelengths
The absorbance is linearly related to the concentration of orthophosphate in the sample. Based on this relationship, the suction can be applied
Convert the luminosity into the concentration value of total phosphorus (TP) or orthophosphate (PO4) in the sample.
2、 Product Features
The new photoelectric quantitative technology is not affected by interference such as high chromaticity, suspended solids, and bubbles, with high reliability and accuracy, and strong anti-interference ability.
High detection accuracy, low measurement limit, and small long-term drift of the instrument.
It has one click self-test function and self diagnostic function.
Adopting a single channel highly integrated valve group, maintenance and cleaning are simple and fast.
24/7 networking function, monitoring instrument operation status anytime, anywhere.
It has alarm function, quality control function, and reverse control function.
It has automatic cleaning and calibration functions.
Capable of whole point measurement, interval measurement, and external control measurement.
Automatically work after power failure and recovery.
Automatic prompt and reset function for faults and missing reagents (samples).
L has fault recording function.
L can save historical data for more than 3 years. Separate the discharge of cleaning solution and waste liquid
3、 Technical parameters
Measurement method: Ammonium molybdate spectrophotometric method (HJ670-2013)
Measurement range: 0-2 mg/L; 0-10 mg/L ; 0-50 mg/L ; Customizable range
Indication error: ≤± 3% Detection limit: 0.010mg/L
Repeatability: ≤± 3% Waste liquid volume: 4.5mL/time
Memory effect: ≤± 1% Actual water sample comparison: ± 8%
Constant temperature time: 900 seconds Voltage stability: ≤± 5%
Measurement cycle: 39 minutes Calibration cycle: any specified time
Maintenance cycle: ≥ 720h/time Maintenance workload:<2 hours/month
Reagent consumption: 3 months/500ml Display output: Equipped with a 10.1-inch color LCD touch screen
Color rendering temperature: The recommended temperature is 120 ℃, which can be set according to the actual water sample situation
Data export: Measurement values can be imported into a USB drive through a USB port and saved
Signal output: RS485/RS232/USB interface/standard 2-channel 4-20mA output/standard 2-channel switch input/output
Environmental requirements: Temperature controlled indoor environment, recommended temperature (5-28 ℃), humidity ≤ 90% (no condensation)
Power supply and output: (220V ± 22) V/AC, (50 ± 0.5Hz), 5A, 150W
Instrument size: Upper cabinet 601 * 450 * 301mm; Upper cabinet 701 * 450 * 301mm






AfterSalesService :
Key words:- Total phosphorus online automatic monitoring instrument