UK Kane KM950 flue gas analyzer nitrogen oxide detector RTO export nitrogen oxide detector
Category:
Instrumentation/Gas analyzer/flue gas analyzer
Model:
KM950
Brand:
Kane, UK
brand:
Kane, UK
model:
KM950
resolution:
0.1PPM
measurement object:
O2 CO NO NO2 NOX SO2 CO2
measurement range:
0-1000PPM
power supply voltage:
two hundred and twenty
type:
portable
display mode:
digital display
structural style :
handheld
Processing & Customization:
No
gas flow rate:
seven hundred
Specifications:
kane
manufacturer:
Kane, UK
Retail Price
31,000.00USD
重量
kg
- Product Description
-
brand Kane, UK
model KM950
resolution 0.1PPM
measurement object O2 CO NO NO2 NOX SO2 CO2
measurement range 0-1000PPM
power supply voltage two hundred and twenty
type portable
display mode digital display
structural style handheld
Processing & Customization No
gas flow rate seven hundred
Specifications kane
manufacturer Kane, UK
Description :
UK Kane KM950 Smoke Analyzer Nitrogen Oxide Detector RTO Export Nitrogen Oxide Detector Imported Portable Smoke Analyzer
UK Kane KM950 flue gas analyzer nitrogen oxide detector RTO export nitrogen oxide detector
RCHB123: I33450I4433 Same V
Some people say,
Life is life, work is work,
I never thought so.
I have always believed that work and life are inseparable,
Integrating work into life can make work more humane,
Life mixed with work can make life more vibrant.
Where is our original intention and focus,
Time will be secretly given to you unintentionally
Don't worry, take your time
Moved ● ﹏ ●
I really love learning,
It's the kind of gaze that yearns for knowledge.
Enrich oneself, summarize and be good at summarizing
Make it when there is an order
When there are no orders, opportunities will be created to find orders
Gentle yet firm towards life




Kane, UKKM950flue gas analyzer Introduction:
Suitable for boiler combustion testing and pollution emission monitoring
Handheld, fully displayed in Chinese, easy to operate and convenient for on-site use
Can measure O2, SO2, NO, NO2, CO, flue gas temperature, ambient temperature, flue gas pressure, total efficiency
Automatically calculate flue gas flow rate CO2、NOx、 Net efficiency, total loss, net loss, excess air coefficient
Built in dual head powerful vacuum pump ensures normal operation under high negative pressure and fast response time
Flexible combination of CO, SO2, NO, NO2 sensors, easy to upgrade
The results show that the conversion between percentage concentration, ppm, and mg/m3 is arbitrary
Measurement alarm limits for different gas components can be set separately
The internal special gas path design reduces the loss of SO2 and NOx during testing
Automatically perform sensor cross interference correction based on smoke status
Large screen display, backlight function facilitates normal use of the instrument in dim conditions
Directly display the flow rate of flue gas through pressure measurement
After booting up, you can directly enter the testing interface without pressing any keys, which is simple and convenient
Dual use of AC and DC, capable of continuous operation for 6 hours on a full charge
Data storage function
Infrared printing method
Built in automatic calibration program facilitates users to calibrate themselves
Users can customize the printing content




Kane, UKKM950flue gas analyzer Technical Specifications:
parameter
resolution
precision
scope
Instructions
flue gas temperature
0.01oC
0.01 ℃± 0.3% reading
0-1200oC
&Use a high-temperature probe at 600 ℃
ambient temperature
0.01oC
0.01 ℃± 0.3% reading
-50℃~50℃
pressure
1pa
± 2.0% reading
±15000pa
Over range ± 25000pa
Gas measurement
O2
0.01%
± 0.2% reading
0-25%
Except for O2 (which is a mandatory test item), users can choose 1-3 sensors from SO2, NO, NO2, and CO according to their needs. The measurement range can also be selected, but it is not possible to select the same sensor for two concentrations at the same time.
CO
1ppm
± 5% reading
0-10,000ppm
NO (standard range)
1ppm
± 5% reading
0-5000ppm
NO (low range)
1ppm
± 5% reading
0-200ppm
NO2
1 ppm
± 5% reading
0-1000ppm
SO2 (standard range)
1ppm
± 5% reading
0-5000ppm
SO2 (low range)
1ppm
± 5% reading
0-200ppm
automatic calculation
CO2
0.1%
± 0.3% reading
0-99.9%
NOx
1ppm
± 5% reading
0-6000ppm
loss
0.1%
± 1.0% reading
0-99.9%
combustion efficiency
0.1%
± 1.0% reading
0-99.9%
Excess air coefficient
0.1%
±0.2%
0-2885.0%
Net temperature
0.01oC
0.01 ℃± 0.3% reading
0-1200oC
Smoke velocity
±0.1m/s
± 2.2% reading
2-45 m/s
Calculate based on flue pressure and temperature
Built in fuel gauge
Coal, light oil, anthracite, natural gas, coal gas, heavy oil, coke, etc
size
220mm ×55mm ×120mm
weight
1kg
power supply
AC/DC dual-use 220V 50Hz or DC12V
Built in rechargeable battery
6 hours of continuous use after fully charged
Standard Configuration
Host, 350mm long probe, dust and water filter, charger, portable bag, operation manual
option
Infrared printer, 1-meter probe (with built-in PTFE tube)
AfterSalesService :
Key words:- Kane KM950 Smoke Analyzer from the UK
More Products