4-20mA signal connection fixed ammonia gas detector RC-GD400 online ammonia monitoring instrument
4-20mA signal connection fixed ammonia gas detector RC-GD400 online ammonia monitoring instrument

4-20mA signal connection fixed ammonia gas detector RC-GD400 online ammonia monitoring instrument

Category:

Instrumentation/Indoor environmental protection testing instruments/Ammonia gas detector

Model:

RC-GD400

Brand:

Thermal Holding Environmental Protection

model:

RC-GD400

type:

fixed type

measurement range:

0-100ppm

measurement object:

ammonia

measurement accuracy:

zero point two one

resolution:

0.1ppm

power supply:

two hundred and twenty

Processing & Customization:

yes

Scope of Application:

Ammonia environment

Overall dimensions:

201mm×176mm×80mm

manufacturer:

Thermal Holding Environmental Protection

Retail Price

4,000.00USD


重量

kg

  • Product Description
  • model

    RC-GD400

    type

    fixed type

    measurement range

    0-100ppm

    measurement object

    ammonia

    measurement accuracy

    zero point two one

    resolution

    0.1ppm

    power supply

    two hundred and twenty

    Processing & Customization

    yes

    Scope of Application

    Ammonia environment

    Overall dimensions

    201mm×176mm×80mm

    manufacturer

    Thermal Holding Environmental Protection

    Description :

      4-20mA signal connection, Lubo fixed ammonia gas detector LB-MD4X

      RCHB123:I3345OI4433sameV Mr. Wang will talk to you about today's equipment content.

      Address: Zhengyang Middle Road, Chengyang Street, Chengyang District, Qingdao City, Shandong Provincetwenty-eightZhengyangtian Streetfivebuildingtwounitone thousand three hundred and five

      RCHB123

      Dingdang accompanied Nobita for 80 years, before Nobita's death

      He said to Dingdang:

      After I leave, go back to where you belong

      Dingdang agreed!

      After Nobita's death

      Dingdang used a time machine to travel back 80 years

      To Doraemon when he was a child:

      Hello Doraemon, my name is Ding Dang. Every time I see this joke, I am so moved

      -----Life is like meeting someone first!

      Whether it's friends or lovers, if we're tired, we'll go back to the day we met in D

      RC-GD400Fixed toxic gas detector Product Introduction

       RC-GD400 is a fixed detector that can be paired with 1 to 6 types of toxic and harmful gases, and can also be equipped with temperature and humidity sensors according to customer requirements. Temperature and humidity sensors do not occupy the gas slot. The RC-GD400 fixed toxic gas detector can continuously monitor the gas concentration of toxic and harmful gases for 24 hours.

      Widely used in storage, municipal gas, fire protection, metallurgy, biomedicine, energy and power, power plants, emergency detection, confined space detection, pipeline detection, petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment and all other occasions that require fixed installation and online detection of gas concentration.

      RC-GD400Fixed toxic gas detectorProduct Features:

      1. Detecting toxic gas concentration

      2. Standard bus RS485 and 4-20mA standard signal output simultaneously

      3. The infrared remote control device can set alarm points, calibrate, restore factory settings, etc

      4. Optional wireless remote transmission and network transmission for real-time monitoring

      5. Gas concentration units can be quickly switched

      6. Standard 100000 data storage capacity

      7. Chinese and English display interface

      8. 3 sets of relay switch output, sound and light alarm (optional), display screen visual alarm

      9. Intrinsic safety circuit design, explosion-proof, with secondary lightning protection and anti-static capabilities

      10. Optional high-temperature and high humidity pretreatment system for handling more complex environments

      

      RC-GD400Technical parameters of fixed toxic gas detector

      Gas detection: Customized according to customer needs (can be single, 2-in-1, 3-in-1, 4-in-1, 5-in-1, 6-in-1, can also be optionally equipped with temperature and humidity sensors, without occupying gas card slots)

      Detection principle: Electrochemical catalytic combustion PID photoionization infrared

      Sampling method: diffusion type

      Installation methods: pipeline type, wall mounted type

      Accuracy: ± 2% FS

      Repeatability: ≤± 1%

      Linearity: ≤± 1%

      Response time: T90 ≤ 20S

      Display mode: 2.5-inch high-definition color screen

      Signal output: Bus based RS485 and 4-20mA, wireless transmission (optional)

      Working voltage: 12-30V

      Connecting cable: Three core shielded wire

      Data storage: 100000 pieces of data capacity

      Protection level: IP66

      Explosion proof grade: Exia Ⅱ CT6

      Working temperature: -40 ℃~70 ℃

      Working humidity: 10-95% RH

      Size and weight: 201mm × 176mm × 80mm 1.8kg

      

      Pre treatment systems can be selected according to the customer's on-site working conditions, whether they are explosion-proof or not. Let's take a look at the actual pictures and find out what you feel~

    AfterSalesService :

    Key words:
    • Online ammonia monitoring device