Online Water Quality Automatic Monitor RC-2202 Environmental Water Quality COD Ammonia Nitrogen Automatic Monitor
Category:
Environmental Protection/Analytical instruments/COD analyzer
Model:
RC-2202
Brand:
Thermal Holding Environmental Protection
model:
RC-2202
measurement range:
10-5000 mg/L
Scope of Application:
COD detection
Processing & Customization:
yes
type:
Online matters
Specifications:
thirty-four
accuracy:
two
Measurable sample status:
three
repeatability error:
two
weight:
forty
Place of Origin:
Qingdao
manufacturer:
Qingdao Hot Holding Environmental Protection
Retail Price
20,000.00USD
重量
kg
- Product Description
-
model RC-2202
measurement range 10-5000 mg/L
Scope of Application COD detection
Processing & Customization yes
type Online matters
Specifications thirty-four
accuracy two
Measurable sample status three
repeatability error two
weight forty
Place of Origin Qingdao
manufacturer Qingdao Hot Holding Environmental Protection
Description :
Online water quality automatic monitoring instrument, environmental protection water quality COD ammonia nitrogen automatic monitoring instrument
Online water quality testing equipment, including regular ones:
Online COD automatic monitoring instrument
Online ammonia nitrogen automatic detector
Online total phosphorus automatic detector
Online total nitrogen automatic detector
RCHB123: I3345OI4433 and V Wang will share with you today's equipment content.
Address: Room 1305, Unit 2, Building 5, Zhengyang Tianjie, No. 28 Zhengyang Middle Road, Chengyang Street, Chengyang District, Qingdao City, Shandong Province
Special statement: According to the Advertising Law, prohibited advertising words are not allowed when describing goods. We support the new advertising law. In order not to affect users' normal browsing, the regional company is clearly investigating and modifying it, and once again stating that all prohibited advertising words on all pages of this website will be invalidated by this statement and will not be used as a reason for compensation.
Product Introduction
The 2202 Chemical Oxygen Demand (COD) online analyzer is a fully automatic COD online analyzer based on the national standard method - determination of chemical oxygen demand using the dichromate method. Through the oxidation-reduction reaction inside the mixed solution formed by water sample, potassium permanganate, Liu Suan silver (as a catalyst to oxidize straight chain aliphatic compounds more fully) and concentrated Liu Suan under high temperature and high pressure environment, Cr (VI) in the solution is reduced to Cr (III), resulting in a change in the color of the mixed solution. The degree of color change of the solution corresponds to the chemical oxygen demand (COD) of the water sample, and the instrument can directly measure the COD value of the water sample through optical signals. The chloride ions in the water sample are the main interfering substances, and the interference of chlorine can be eliminated by adding mercury content to chelate the chloride ions in the water sample.
Widely used in various fields such as sewage treatment plants, washing plants, chemical wastewater discharge outlets, industrial production process water, and industrial and municipal wastewater treatment.
Usually used in sewage treatment plants, or by polluting enterprises, industrial production units for sewage discharge, and online heavy metal automatic monitoring devices used in coal mines
Many users need to purchase through intermediaries, so many intermediaries are not familiar with it and will consult us if they have many questions. Below, Qingdao Hot Holding Environmental Protection Wang Xiaobian will share with you the basic information of online water quality monitoring instruments
1: The online water quality detector replaces manual testing, saving manpower and resources, and the detection information can be uploaded to the data platform of the Environmental Protection Bureau in real time,
It's normal to monitor every two hours
A day is counted as 24 hours, which means 12 times, and the price of each reagent does not exceed 1000 yuan.
2: Online monitoring, what should I do if it exceeds the standard?
For example, in an online COD monitoring device, if the data exceeds the standard, the environmental protection bureau platform will display and alert the user. The environmental protection bureau will call the user, and at the same time, if the user matches an online water quality sampler, the excess sample can be retained. Why is the excess sample retained? Is the excess water sample retained? This way, users can verify for themselves whether it really exceeds the standard.
3: Another issue is installation, to put it simply:
When the goods arrive at the site, the user checks for any damage. If not, we will go to the site according to the customer's requirements. If they request to go to the site, we will arrange for technicians to provide installation, debugging, and basic maintenance training for the user.
Regarding installation, our technical team provides on-site installation and debugging services, excluding civil engineering.
Also, if the customer has the ability to install it themselves, they can also install it themselves. We can provide phone or video guidance for installation. This will also save some costs.
The accessories and materials used on site are usually PE pipes and adapters, which cost very little. After the technology arrives at the site, the user and the technology can go to the market together to buy them. Why are the manufacturers not qualified? It is inconvenient to ship PE pipes as the auxiliary materials are available in the local market and transportation is also inconvenient. Therefore, it is recommended to purchase them locally.
That's all for the basic categories. For more detailed questions, you can consult Qingdao Re Chi Environmental Protection Wang Xiaobian. Looking forward to your call~~
execution standard
GB11914-1989 "Determination of Chemical Oxygen Demand for Water Quality, Heavy Chromium Suan Potassium Method"
HJ/T 377-2007 "Chemical Oxygen Demand (CODcr) Water Quality Online Automatic Monitoring Instrument"
Performance Characteristics
1. Select valve components: Choose reagent sampling timing, flexible and diverse channels, versatile functions, and advantages such as easy maintenance and high lifespan.
2. It has printing function and can be connected to a printer (optional) to print the measured data in a timely manner.
3. Adopting a 7-inch touch screen and a simple operating interface, it can be easy for users to learn, operate, and maintain.
4. The extremely large data storage capacity enables the preservation of historical data for no less than 5 years (with a measurement interval of 1 time/1 hour), greatly meeting the needs of customers.
5. Automatic liquid leakage alarm function, when a reagent leakage occurs, the instrument will automatically alarm and prompt the user to perform maintenance.
6. The use of optical signal recognition function ensures high accuracy in quantitative analysis.
7. The maintenance of chemical reagents is simplified and convenient, with a monthly replacement of reagents, greatly reducing the maintenance workload for users.
8. Accurate measurement of COD at 35000mg/L chloride ions can be achieved.
9. One click upgrade of USB flash drive makes software updates easier.

Technical Specifications
Method basis
Determination of Chemical Oxygen Demand - Dichromate Method
measurement range
10-5000 mg/L COD
accuracy
When ≥ 100mg/L, not exceeding ± 10%; When<100mg/L, not exceeding ± 4mg/L
repetitiveness
When ≥ 100mg/L, not exceeding ± 10%; When it is less than 100mg/L, it should not exceed ± 4mg/L.
measurement period
The minimum measurement cycle is 20 minutes, and according to the actual water sample, the digestion time can be modified arbitrarily within 5-120 minutes
sampling period
Time interval (adjustable from 10 to 9999 minutes) and hourly measurement mode
calibration cycle
Adjustable at any interval and time from 1 to 99 days
maintenance cycle
Usually once a month, about 30 minutes each time
output
RS-232, 4-20mA (optional)
Environmental Requirements
For indoor environments with adjustable temperature, it is recommended to have a temperature range of+5-28 ℃; Humidity ≤ 90% (non condensing)
power supply
AC220±10% V,50±10% Hz,5A
size
Height 1502 x Width 552 x Depth 454 (mm)
AfterSalesService :
Key words:- Online water quality automatic monitoring instrument
More Products