Online Water Quality Automatic Monitor RC-2202 Environmental Water Quality COD Ammonia Nitrogen Automatic Monitor
Online Water Quality Automatic Monitor RC-2202 Environmental Water Quality COD Ammonia Nitrogen Automatic Monitor

Online Water Quality Automatic Monitor RC-2202 Environmental Water Quality COD Ammonia Nitrogen Automatic Monitor

Category:

Environmental Protection/Analytical instruments/COD analyzer

Model:

RC-2202

Brand:

Thermal Holding Environmental Protection

model:

RC-2202

measurement range:

10-5000 mg/L

Scope of Application:

COD detection

Processing & Customization:

yes

type:

Online matters

Specifications:

thirty-four

accuracy:

two

Measurable sample status:

three

repeatability error:

two

weight:

forty

Place of Origin:

Qingdao

manufacturer:

Qingdao Hot Holding Environmental Protection

Retail Price

20,000.00USD


重量

kg

  • Product Description
  • model

    RC-2202

    measurement range

    10-5000 mg/L

    Scope of Application

    COD detection

    Processing & Customization

    yes

    type

    Online matters

    Specifications

    thirty-four

    accuracy

    two

    Measurable sample status

    three

    repeatability error

    two

    weight

    forty

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Hot Holding Environmental Protection

    Description :

    Online water quality automatic monitoring instrument, environmental protection water quality COD ammonia nitrogen automatic monitoring instrument

    Online water quality testing equipment, including regular ones:

      Online COD automatic monitoring instrument

      Online ammonia nitrogen automatic detector

      Online total phosphorus automatic detector

      Online total nitrogen automatic detector

      RCHB123: I3345OI4433 and V Wang will share with you today's equipment content.

      Address: Room 1305, Unit 2, Building 5, Zhengyang Tianjie, No. 28 Zhengyang Middle Road, Chengyang Street, Chengyang District, Qingdao City, Shandong Province

      Special statement: According to the Advertising Law, prohibited advertising words are not allowed when describing goods. We support the new advertising law. In order not to affect users' normal browsing, the regional company is clearly investigating and modifying it, and once again stating that all prohibited advertising words on all pages of this website will be invalidated by this statement and will not be used as a reason for compensation.

    Product Introduction

      The 2202 Chemical Oxygen Demand (COD) online analyzer is a fully automatic COD online analyzer based on the national standard method - determination of chemical oxygen demand using the dichromate method. Through the oxidation-reduction reaction inside the mixed solution formed by water sample, potassium permanganate, Liu Suan silver (as a catalyst to oxidize straight chain aliphatic compounds more fully) and concentrated Liu Suan under high temperature and high pressure environment, Cr (VI) in the solution is reduced to Cr (III), resulting in a change in the color of the mixed solution. The degree of color change of the solution corresponds to the chemical oxygen demand (COD) of the water sample, and the instrument can directly measure the COD value of the water sample through optical signals. The chloride ions in the water sample are the main interfering substances, and the interference of chlorine can be eliminated by adding mercury content to chelate the chloride ions in the water sample.

      Widely used in various fields such as sewage treatment plants, washing plants, chemical wastewater discharge outlets, industrial production process water, and industrial and municipal wastewater treatment.

      Usually used in sewage treatment plants, or by polluting enterprises, industrial production units for sewage discharge, and online heavy metal automatic monitoring devices used in coal mines

      Many users need to purchase through intermediaries, so many intermediaries are not familiar with it and will consult us if they have many questions. Below, Qingdao Hot Holding Environmental Protection Wang Xiaobian will share with you the basic information of online water quality monitoring instruments

      1: The online water quality detector replaces manual testing, saving manpower and resources, and the detection information can be uploaded to the data platform of the Environmental Protection Bureau in real time,

      It's normal to monitor every two hours

      A day is counted as 24 hours, which means 12 times, and the price of each reagent does not exceed 1000 yuan.

      2: Online monitoring, what should I do if it exceeds the standard?

      For example, in an online COD monitoring device, if the data exceeds the standard, the environmental protection bureau platform will display and alert the user. The environmental protection bureau will call the user, and at the same time, if the user matches an online water quality sampler, the excess sample can be retained. Why is the excess sample retained? Is the excess water sample retained? This way, users can verify for themselves whether it really exceeds the standard.

      3: Another issue is installation, to put it simply:

      When the goods arrive at the site, the user checks for any damage. If not, we will go to the site according to the customer's requirements. If they request to go to the site, we will arrange for technicians to provide installation, debugging, and basic maintenance training for the user.

      Regarding installation, our technical team provides on-site installation and debugging services, excluding civil engineering.

      Also, if the customer has the ability to install it themselves, they can also install it themselves. We can provide phone or video guidance for installation. This will also save some costs.

      The accessories and materials used on site are usually PE pipes and adapters, which cost very little. After the technology arrives at the site, the user and the technology can go to the market together to buy them. Why are the manufacturers not qualified? It is inconvenient to ship PE pipes as the auxiliary materials are available in the local market and transportation is also inconvenient. Therefore, it is recommended to purchase them locally.

      That's all for the basic categories. For more detailed questions, you can consult Qingdao Re Chi Environmental Protection Wang Xiaobian. Looking forward to your call~~

      execution standard

      GB11914-1989 "Determination of Chemical Oxygen Demand for Water Quality, Heavy Chromium Suan Potassium Method"

      HJ/T 377-2007 "Chemical Oxygen Demand (CODcr) Water Quality Online Automatic Monitoring Instrument"

      Performance Characteristics

      1. Select valve components: Choose reagent sampling timing, flexible and diverse channels, versatile functions, and advantages such as easy maintenance and high lifespan.

      2. It has printing function and can be connected to a printer (optional) to print the measured data in a timely manner.

      3. Adopting a 7-inch touch screen and a simple operating interface, it can be easy for users to learn, operate, and maintain.

      4. The extremely large data storage capacity enables the preservation of historical data for no less than 5 years (with a measurement interval of 1 time/1 hour), greatly meeting the needs of customers.

      5. Automatic liquid leakage alarm function, when a reagent leakage occurs, the instrument will automatically alarm and prompt the user to perform maintenance.

      6. The use of optical signal recognition function ensures high accuracy in quantitative analysis.

      7. The maintenance of chemical reagents is simplified and convenient, with a monthly replacement of reagents, greatly reducing the maintenance workload for users.

      8. Accurate measurement of COD at 35000mg/L chloride ions can be achieved.

      9. One click upgrade of USB flash drive makes software updates easier.

      Technical Specifications

      Method basis

      

      Determination of Chemical Oxygen Demand - Dichromate Method

      

      measurement range

      

      10-5000 mg/L COD

      

      accuracy

      

      When ≥ 100mg/L, not exceeding ± 10%; When<100mg/L, not exceeding ± 4mg/L

      

      repetitiveness

      

      When ≥ 100mg/L, not exceeding ± 10%; When it is less than 100mg/L, it should not exceed ± 4mg/L.

      

      measurement period

      

      The minimum measurement cycle is 20 minutes, and according to the actual water sample, the digestion time can be modified arbitrarily within 5-120 minutes

      

      sampling period

      

      Time interval (adjustable from 10 to 9999 minutes) and hourly measurement mode

      

      calibration cycle

      

      Adjustable at any interval and time from 1 to 99 days

      

      maintenance cycle

      

      Usually once a month, about 30 minutes each time

      

      output

      

      RS-232, 4-20mA (optional)

      

      Environmental Requirements

      

      For indoor environments with adjustable temperature, it is recommended to have a temperature range of+5-28 ℃; Humidity ≤ 90% (non condensing)

      

      power supply

      

      AC220±10% V,50±10% Hz,5A

      

      size

      

      Height 1502 x Width 552 x Depth 454 (mm)

      

    AfterSalesService :

    Key words:
    • Online water quality automatic monitoring instrument