Non dispersive infrared CO analyzer RC-3011 Infrared CO analyzer National standard method Non dispersive infrared principle
Non dispersive infrared CO analyzer RC-3011 Infrared CO analyzer National standard method Non dispersive infrared principle

Non dispersive infrared CO analyzer RC-3011 Infrared CO analyzer National standard method Non dispersive infrared principle

Category:

Instrumentation/Gas analyzer/Carbon monoxide detector

Model:

RC-3011

Brand:

Thermal Holding Environmental Protection

model:

RC-3011

type:

portable

measurement range:

0-50ppm

measurement object:

CO

measurement accuracy:

±5%

resolution:

0.1PPM

power supply:

two hundred and twenty

voltage:

five

Shell material:

stainless steel

Protection level:

one

Explosion-proof rating:

two

Processing & Customization:

yes

weight:

two

manufacturer:

Qingdao Hot Holding Environmental Protection

Retail Price

12,500.00USD


重量

kg

  • Product Description
  • model

    RC-3011

    type

    portable

    measurement range

    0-50ppm

    measurement object

    CO

    measurement accuracy

    ±5%

    resolution

    0.1PPM

    power supply

    two hundred and twenty

    voltage

    five

    Shell material

    stainless steel

    Protection level

    one

    Explosion-proof rating

    two

    Processing & Customization

    yes

    weight

    two

    manufacturer

    Qingdao Hot Holding Environmental Protection

    Description :

      Non dispersive infrared RC-3011 infrared CO analyzer National standard method Non dispersive infrared principle Portable CO analyzer

      Non dispersive infrared CO analyzer RC-3011 Infrared CO analyzer National standard method Non dispersive infrared principle

      Non dispersive infrared RC-3011 infrared CO analyzer

      The principle of non dispersive infrared in the national standard methodRC-3011infraredCOanalyzer

      Non dispersive infrared radiationRC-3011 infraredCOanalyzer

      RCHB123:I3345OI4433

      Even if it's hard, one must choose a scorching life.

      Accept all the pressure and challenges,

      Just to become a better version of oneself!

      Saying goodbye to October is both the end and the beginning.

      Growing and achieving each other

      1、 InfraredCOBrief Introduction to Gas Analysis:

      It is a technology developed by our company Xin that utilizes the principle of infrared spectroscopy absorption to detect low concentrations ofyiCarbon oxide measuring instrument, infraredyiCarbon oxide detector, also capable of detectingyiCarbon dioxide concentration, temperature, and humidity. Equipped with a very clear color touch screen, sound and light alarm prompts, built-in pump, infraredyiCarbon dioxide gas analyzer is widely used for gas detection and monitoring in public places, health supervision, environmental monitoring, and other areas. Successfully solved the issue, ensuring and compensating for high and low temperature measurements with extremely high accuracy, which can be used in monitoring departments such as scientific research. This instrument complies with the national standards of GB/T18204.2-2014 "Methods for hygiene inspection in public places" and GB/T9801-88 "Determination of air quality - Non dispersive infrared method for carbon dioxide", and conforms to JJG635-2011《yiNational Metrological Verification Regulations for Infrared Gas Analyzer of Carbon Oxide and Carbon Dioxide.

      2、 Characteristics of Infrared CO Gas Analyzer:

      1. Detect CO gas in the air and also measure the temperature and humidity of the environment.

      2. The built-in suction pump can suck gas from tens of meters away into the instrument for measurement.

      3. Equipped with a large color touch screen, it is easy and fast to operate.

      4. The instrument displays two types of data: PPM and mg/M3, which can be automatically converted.

      5. Automatic zero point correction technology, convenient for users to perform zero point correction in different seasons and times

      IIICOgas analyzerTechnical Specifications:

      Detection principle: Non dispersive infrared gas analysis method/Non dispersive infrared method (national standard)

      Gas detection: Carbon monoxide (CO) in the air

      Measurement method: pump suction

      Measurement range: (displaying both ppm and mg/m3 simultaneously)

      CO: Range of 0.0-50ppm or 200, 1000ppm

      Temperature: -20 ∽ 60 ℃. Humidity: 10-95% RH

      Resolution: 0.1 × 10-6

      Linear error: ≤± 2% F · S

      Repeatability: ≤ 1.0%

      Zero drift: ≤± 2% F · S/h

      Range drift: ≤± 2% F · S/3h

      Preheating time: 30 minutes

      Response time: ≤ 60 seconds

      Flow range: (0.5-2.0) L/min

      Power supply: AC/DC dual-use, 220V (± 10%) or built-in rechargeable battery

      4、 Infrared CO gas analyzerto configure:

      (1) One instrument host (including built-in battery)

      (2) One charger

      (3) One sampling hose

      (4) One aluminum alloy carrying case

       (5) One copy of the operation manual

      (6) One certificate of conformity

      

    AfterSalesService :

    Key words:
    • Non dispersive infrared CO analyzer