American Huarui VOC detector ppbRAE3000 portable VOC detector handheld VOC detector
American Huarui VOC detector ppbRAE3000 portable VOC detector handheld VOC detector

American Huarui VOC detector ppbRAE3000 portable VOC detector handheld VOC detector

Category:

Instrumentation/Indoor environmental protection testing instruments/VOC detection instrument

Model:

ppbRAE3000+

Brand:

RAE/Huarui

brand:

RAE/Huarui

model:

ppbRAE3000+

type:

handheld

measurement object:

Volatile organic gases

measurement range:

1ppb-10000ppm

measurement accuracy:

2%

resolution:

0.1ppm

power supply:

two hundred and twenty

Processing & Customization:

No

weight:

zero point four five

manufacturer:

American Huarui or American Honeywell

Retail Price

29,800.00USD


重量

kg

  • Product Description
  • brand

    RAE/Huarui

    model

    ppbRAE3000+

    type

    handheld

    measurement object

    Volatile organic gases

    measurement range

    1ppb-10000ppm

    measurement accuracy

    2%

    resolution

    0.1ppm

    power supply

    two hundred and twenty

    Processing & Customization

    No

    weight

    zero point four five

    manufacturer

    American Huarui or American Honeywell

    Description :

      American Huarui VOC detector PGM7340 ppbRAE3000+portable VOC detector volatile organic gas analyzer handheld VOC detector

      American Huarui VOC detector ppbRAE3000 portable VOC detector handheld VOC detector

      RCHB123:I3345OI4433sameV Mr. Wang will talk to you about today's equipment content.

      American Huarui, also known as American Honeywell, why do you say that? After the acquisition of American Huarui by Honeywell, the American Huarui industry exists as a separate brand, so there are both American Huarui and American Honeywell in the market.

      Currently, most volatile organic gas detectors use high-precision PID detection principles, and their properties determine that the VOCs they check are the sum of all volatile organic gases on site, and they will not distinguish them separately. Please remember this.

      Also, does the editor have something to say here? How to put it, the editor thinks that all devices and inspection instruments are born to serve users and only have value when needed. For example, if you have high hopes for this imported British ion tiger brand VOC detector, but suffer from high temperatures on your testing site, what should you do? We all know that inspection equipment in conventional environments can only be used in normal temperature environments. For high temperature environments, certain measures need to be taken or the site needs to be cooled down. So, are you looking forward to my next article?

      

      For handheld VOC detectors, we often come into contact with imported brands such as Ion ION from the UK, Huarui (Honeywell) from the US, and Mengpu'an from the US

      These three brands are the ones we currently use more frequently, and of course, each brand has its own separately configured model. According to customer requirements, the resolution is 0.1ppm, 0.01ppm, or 0.001ppm, which is 1ppb. In the process of daily sales, we often encounter customers inquiring about the relationship between ppm and ppb. So let me explain here, 1ppm=1000ppb, that's the relationship. It's very simple, isn't it.

      American Huarui VOC detector PGM7340 ppbRAE3000+portable VOC detector volatile organic gas analyzer handheld VOC detector

      Definition of VOCs

      

      1: Product Description:

      PPbRAE 3000 is the most sensitive broad-spectrum handheld volatile organic compound (VOC) gas detector on the market today. It uses RAE's latest third-generation photoionization detector (PID) to improve detection accuracy and response time, with a detection range of 1ppb-10000ppm. Through a wireless module, it can achieve wireless data transmission and remote monitoring with the console. It can be widely applied in industries such as environmental protection, occupational health and hygiene, emergency rescue, industrial safety, petroleum and petrochemical.

      Short response time, wide detection range, high resolution, and small detection error

      Can achieve the resolution of analytical instruments

      Can achieve a resolution of 1 ppb and provide real-time on-site detection data in 2 seconds

      Self cleaning patented technology

      The self-cleaning technology of ultraviolet lamps maintains the energy of the lamp in a stable state, reducing maintenance costs

      The Perfect Application of Wireless Technology in Gas Detection

      Built in Bluetooth or wireless module for real-time data transmission

      Built in powerful sampling pump

      It can be connected to a sampling pipeline up to 30m in length, and the detection data is equally accurate and error free

      Intelligent temperature and zero point compensation algorithm

      Built in temperature, humidity, and pressure sensors automatically compensate to ensure accurate detection

      Friendly human-machine interface

      Large screen graphic LCD display, multiple languages, supports Chinese

      Can detect thousands of gases

      Broad spectrum detection, built-in gas database, convenient for users to choose

      2: Technical parameters:

      Size: 25.5 × 7.6 × 6.4 cm

      Weight: 738g (including lithium battery)

      Sampling method: pump suction

      Shell material: engineering plastic, rubber jacket

      Protection level: IP66 (power on)/IP67 (power off), completely dust-proof, water repellent

      Anti electromagnetic radiation: EMI/RF level: EMC Directive 2004/108/EEC

      Working temperature: -20 ℃~50 ℃

      Environmental humidity: 0% to 95% relative humidity (without condensation)

      ATEX certification: II 1G EEx ia IIC T4

      UL/cUL/CSA certification: Class I, Division 1, Group A, B, C, D

      IECEx certification: Ex ia IIC T4

      Display screen: Large screen graphic LCD display with automatic backlight

      Display language: Chinese/English+symbols

      Display content: real-time detection value, TWA value, STEL value, peak value, battery voltage, date and time, temperature

      Keys: 1 operation key, 2 function keys, 1 lighting switch

      Alarm method: 95dB@30cm Buzzer, red LED

      Alarm signals: gas exceeding the standard, insufficient battery voltage, sensor malfunction, low battery level alarm

      Alarm point setting: separate settings for TWA, STEL, and high/low alarm limits

      Data storage: Built in storage capacity of 260000 data points (with a 1-minute interval of approximately 2 months), recording content including date, time, serial number, user ID, detection point ID, etc

      Sampling interval: adjustable from 1-3600 seconds

      Data communication: USB (via base), RS232 (via travel charger), optional built-in Bluetooth module to download detection data, upload instrument parameter settings; Optional built-in wireless module for wireless data transmission

      Sampling pump flow rate: 450cc/min to 550cc/min

      Battery: 4.2V/3300mAh rechargeable lithium-ion battery, alkaline battery box uses 4 AA batteries

      Running time: Can work continuously for 16 hours (depending on the working environment and frequency of use)

      Charging time: 8 hours

      Calibration method: two-point/three-point zero point/extended calibration

      Sensor configuration: Standard 10.6eV (optional 9.8/11.7eV) PID sensor for UV lamp

      Sensor parameters:

      UV lamp type detection range resolution

      10.6eV 1ppb ~10000ppm 1ppb

      Standard configuration with only one EV light 10.6eV

      9.8eV 0.01ppm ~5000ppm 10ppb

      11.7eV 0.1ppm ~2000ppm 10ppb

      Response time (T90): 2s

      Detection accuracy: ± 3% of the 10-2000ppm isobutene standard point

      

      3: Main features:

      Third generation PID sensor with short response time and wide detection range

      Large screen graphic LCD display, graphic menu display

      Automatic backlight display, built-in lighting, convenient for use in dark environments

      Built in temperature, humidity, and pressure sensors with automatic humidity compensation to ensure measurement accuracy

      Quickly replace sensors and batteries without the need for any tools

      Automatic recognition of UV lamp model

      Sensor and UV lamp automatic cleaning

      Multi language display, supporting Chinese

      Built in powerful suction pump

      4: Standard configuration:

      PGM-7340 host, including sensors and UV lamps

      Lithium battery, charging/data download dock

      Rubber protective cover

      Inlet pipe and water trap filter

      Operation Manual

      Data and software CD

      Portable soft bag

      5: Application areas:

      Industrial safety monitoring;

      Environmental protection monitoring;

      Safety testing for petrochemical and plastic production enterprises

       Oil tanker, railway, aviation, industrial pipeline inspection

      Hazardous substance testing

      

      

    AfterSalesService :

    Key words:
    • Handheld VOC detector