Integrated hydrant and cannon fire hydrant, ground fire hydrant, outdoor antifreeze fire hydrant, fire hydrant manufacturer
Integrated hydrant and cannon fire hydrant, ground fire hydrant, outdoor antifreeze fire hydrant, fire hydrant manufacturer

Integrated hydrant and cannon fire hydrant, ground fire hydrant, outdoor antifreeze fire hydrant, fire hydrant manufacturer

Category:

Security/Firefighting equipment/Other fire-fighting equipment

Model:

SSFT150/65-1.6

Brand:

Eastern Mountain

Retail Price

2,200.00USD


重量

kg

  • Product Description
  • Description :

      The main products of Shandong Dongyue Crane Fire Fighting Equipment Manufacturing Co., Ltd. include PS series fixed fire monitor, PL series foam water dual-use monitor, PSY series mobile fire monitor, PSKD series fixed fire monitor, PSKDY series mobile fire monitor, automatic tracking and positioning jet extinguishing device, SSFT series ground fire hydrant, hydrant monitor integrated fire hydrant, PZK series fire gun base, PS series foam fire hydrant, PY series semi fixed (portable) foam extinguishing device, PHYM (L) series pressure proportional mixing device, PQ series foam gun, PHP series balanced foam proportional mixing There are more than 200 kinds of fire-fighting supporting products, such as devices, PSG series foam hydrant boxes, PC (L) series low expansion air foam generators, PT series fire turrets, FQS series fire ball valves, steel tank fire cooling spray devices, foam extinguishing agents, etc.

      Shandong Dongyue Crane and Fire Protection Equipment Manufacturing Co., Ltd. is a key manufacturer of construction cranes and fire protection equipment recognized by the State Administration of Quality Supervision, Inspection and Quarantine and the State Fire Protection Administration. It is also a member unit of the China Fire Protection Association and major provincial (municipal) and autonomous region fire protection associations.

      All products of the company have passed the 3C certification of the Fire Safety Qualification Assessment Center of the Emergency Management Department, and obtained corresponding product inspection reports and 3C certificates. The company implements ISO9001 quality management system certification, environmental review report, safety review report and other system certifications. The product has advanced performance, reliable quality, and high reputation. Adhere to the concept of "survival through quality, development through reputation"; Adhering to the principles of "integrity, focus, and quality", we will provide technical solutions and excellent product performance to wholeheartedly serve our customers both domestically and internationally.

      The SSFT series outdoor fire hydrants produced by Shandong Dongyue Crane and Fire Equipment Manufacturing Co., Ltd. are mainly composed of valve sockets, lower valve body components, connecting pipes, fire hydrant shells (integrated with hydrants and cannons) and other components. Fire water cannons or fire water bags can be connected as needed to adapt to different situations. Users can adjust the water pressure and water volume using the built-in wrench of the product,; The opening method is to open the lifting shaft. During the opening process, the internal connecting rod moves vertically downwards, and the pressure of the internal fire water causes the internal pressure reducing device to open in sections. First, a part of the water flows upward through the pressure reducing device, and then another section is opened after a certain period of time to achieve the pressure regulating effect; When using this product, the internal device seals the automatic drainage device during movement. After use, the top rod of the originally sealed drainage device leaves, and the water left in the upper half after use is automatically discharged.

      People generally believe that as soon as a fire truck arrives at the scene of a fire, it can immediately release water to extinguish the fire. In fact, a considerable number of fire trucks equipped in the fire brigade do not carry water, such as lifting fire trucks, emergency rescue vehicles, fire lighting vehicles, etc., which must be used in conjunction with firefighting fire trucks. Some fire trucks, due to their limited water capacity, urgently need to find a water source when extinguishing fires. At this point, the fire hydrant plays a huge role in supplying water.

      Key points for selection

      1. When the building is within a 150m radius of municipal fire hydrant protection and the fire water consumption does not exceed 15L/s, outdoor fire hydrants may not be installed.

      2. Outdoor fire hydrants should be evenly arranged around high-rise buildings and should not be concentrated on one side of the building.

      3. The distance between the outdoor fire hydrant of civil air defense engineering and the entrance of civil air defense engineering should not be less than 5m.

      4. The outdoor fire hydrant in the parking lot should be installed along the perimeter of the parking lot, and the distance from the nearest row of cars should not be less than 7m, and the distance from the gas station or garage should not be less than 15m.

      5. Outdoor fire hydrants should be installed in locations that are convenient for fire trucks to use.

      6. Outdoor fire hydrants should be above ground, and when underground fire hydrants are used, there should be clear signs. Underground construction is preferred in cold regions, while above ground construction is recommended in non cold regions. If conditions permit, anti-collision construction can be used for above ground construction.

      7. Outdoor above ground fire hydrants should have a diameter of 150mm or 100mm and two hydrant ports with a diameter of 65mm. Outdoor underground fire hydrants should have one nozzle with a diameter of 100 and one with a diameter of 65mm.

      8. The protection radius of outdoor fire hydrants should not exceed 150m, and the spacing should not exceed 120m.

      9. The distance between outdoor fire hydrants and the roadside should not exceed 2 meters, and the distance from the exterior wall of the house should not be less than 5 meters.

      Type characteristics

      Outdoor fire hydrants include traditional above ground and underground fire hydrants, as well as new types of outdoor direct buried telescopic fire hydrants.

      The above ground water connection is easy to operate, but it is prone to collision and freezing; The underground anti freezing effect is good, but it requires the construction of a large underground well, and when in use, firefighters have to go to the well to collect water, which is very inconvenient.

      Outdoor direct buried telescopic fire hydrants are usually pressed back below the ground and pulled out to work when in use. Compared to above ground models, it can avoid collisions and has better anti freezing effect; More convenient to operate than underground, and simpler to install directly. It is a very new and advanced outdoor fire hydrant.

    AfterSalesService :

    Key words:
    • Integrated fire hydrant with hydrant and cannon