- Product Description
-
Description :






Automatic fire water cannon is called "automatic tracking and positioning jet fire extinguishing device" or "automatic seeking sprinkler fire extinguishing device" according to current national standards; Automatic fire water cannon uses flame sensors to amplify and analyze the unique ultraviolet waves (wavelength range of 180-260nm) and infrared waves (wavelength range of 4.35 ± 0.15 um) of flames, thereby achieving red ultraviolet (or dual wavelength) composite fire detection with high stability and reliability.




The rated flow rate of outdoor water cannons should not be less than 30L/s.
1. The continuous supply time of fire extinguishing and cooling water for the water cannon system shall comply with the following regulations:
The continuous attack time of firefighting water used to extinguish indoor fires should not be less than 1.0 hour.
The continuous supply time of firefighting water for outdoor fires should not be less than 2.0 hours.
2. The supply intensity of fire extinguishing and cooling water for the water cannon system shall comply with the following regulations:
The supply intensity for extinguishing indoor solid material fires should comply with relevant national standards, and the water consumption should be calculated based on the requirement that the water jets from two water cannons reach either part of the protective zone simultaneously. The water consumption of civil buildings should not be less than 40L/s, and the water consumption of industrial buildings should not be less than 60L/s;
The intensity of fire extinguishing and cooling water supply for outdoor fires should comply with relevant national standards;
The fire extinguishing area and cooling area of other places should be determined according to relevant national standards or based on actual situations.
3. The calculated total flow rate of the water cannon system should be the comprehensive design flow rate of the water cannons that need to be started simultaneously in the system, but it should not be less than the sum of the calculated total flow rates of fire extinguishing water and cooling water consumption.