  • Product Description
  • Description :

      1. Fire cannons should be used within the pressure range of their intended use;

      2. The integrity and operational flexibility of the fire monitor should be checked regularly. If loose fasteners are found, they should be repaired in a timely manner to keep the monitor in place

      Good usage condition;

      3. When spraying water, loosen the locking screw, adjust the spraying direction and angle of the fire monitor, and then increase it to the pressure used;

      4. By rotating the jet control ring, the direct current of water can be converted into flowering, or the flowering can be converted into direct current;

      5. After each use, spray water for a period of time and then drain the water from the fire monitor;

      6. The rotating parts of the fire monitor should be regularly lubricated to ensure flexible rotation;

      7. When spraying, no one is allowed to stand in front of the fire cannon;

      8. Fire cannons should not be used to extinguish live equipment to prevent electric shock;

      9. When not in operation, the fire monitor should be placed horizontally and covered with rainproof cloth.

      2、 Structural features and working principle

      1. The structural composition of a fixed fire monitor: The fixed fire monitor mainly consists of a connecting base, a bracket inlet pipe, a rotating body, and a nozzle (including:

      Water outlet pipe, water inlet pipe, double handle), monitor handle, etc. The water monitor head is DC spray type (see Figure 1 for details);

      2. The working principle of a fixed fire monitor:

      a、 Direct current: After passing through the fixed fire monitor body, the water flows in a circular flow with the stabilizer and is sprayed from the muzzle, forming a solid water column at a certain distance;

      b、 Spray: after the water flows through the fixed fire monitor body, the angle between the water flow and the current stabilizer changes by rotating the monitor head, and the water is sprayed from the muzzle to form a foggy water flow.

      Fixed fire monitor performance curve

      Explanation of the Performance Curve of Fixed Fire Cannon:

      In order to better serve users and fire engineering designers, this manual provides curves of the range, firing height, and reaction force of fixed fire monitors of various specifications when spraying different media at different flow rates. When selecting, the rated flow rate of the fixed fire monitor should be used as the basis, and various operating points within the pressure range of the fixed fire monitor should be considered for selection. Here are some examples based on the performance curve:

      1. According to Table 2, the flow rates of fixed fire monitors with different flow specifications can be determined at different injection pressures.

      For example, according to Table 2, the 50 type fixed fire monitor has a jet pressure of 50L/S at 1.0 MPa.

      2. According to Table 3, it can be found that under the conditions given in GB19156 "General Technical Conditions for Fixed Fire Gun" 7, 8, and 1 (fixed fire gun elevation angle of 30, downwind speed ≤ 2m/s), the range of fixed fire guns with different flow specifications can be determined at different injection pressures.

      3. According to Table 4, the firing height of fixed fire monitors with different flow specifications at rated pressure and different elevation angles, as well as the horizontal distance from the firing point to the muzzle, can be determined.

      4. According to the flow specifications and actual working pressure of the fixed fire monitor, the reaction force under this working condition can be determined. When selecting and designing the fixed fire monitor, the reaction force under working pressure can be used as the basis for basic design. For example, according to Table 5, the reaction force of the 50 type fire water bubble under a working pressure of 1.0MPa is 2.5KN. If a working pressure of 1.6MPa may occur in this state, the reaction force of 4.3KN should be used as the basis for basic design.

      Overall dimensions

      model

      

      Length (mm)

      

      Width (mm)

      

      Height (mm)

      

      Connection flange size (DN)

      

      PS20

      

      seven hundred

      

      two hundred and ninety

      

      three hundred and fifteen

      

      DN100 or customized

      

      PS30

      

      seven hundred and ten

      

      three hundred and eighty-four

      

      three hundred and fifty

      

      DN100 or customized

      

      PS40

      

      seven hundred and ten

      

      three hundred and eighty-four

      

      three hundred and fifty

      

      DN100 or customized

      

      PS50

      

      seven hundred and ten

      

      three hundred and eighty-four

      

      three hundred and fifty

      

      DN100 or customized

      

      PS60

      

      seven hundred and ten

      

      six hundred and seventy-five

      

      four hundred and five

      

      DN100 or customized

      

      PS70

      

      seven hundred and ten

      

      six hundred and seventy-five

      

      four hundred and five

      

      DN100 or customized

      

      PS80

      

      seven hundred and ten

      

      six hundred and seventy-five

      

      four hundred and five

      

      DN100 or customized

      

    AfterSalesService :

    Key words:
    • fire monitor