JKLGYJ-10kv-1 * 95/15 Parameters Hubei Shiyan Overhead Insulated Line Manufacturer
Category:
Electrical Engineering/Wire and cable/Insulated wire
Model:
JKLGYJ-10KV-1*95/15
Brand:
Zheng Fan
Retail Price
6.21USD
重量
kg
- Product Description
-
Description :
JKLGYJ-10kv-1 * 95/15 Parameters Hubei Shiyan Overhead Insulated Line Manufacturer
Purpose and characteristics of overhead insulated conductors:
Overhead insulated lines, Aerial Insulation Line, An insulated wire made by twisting single or multiple layers of aluminum wire and extruding an insulation layer outside the wire. This type of wire is erected by a tower at a certain height to transmit power and is suitable for high and low voltage transmission and transformation overhead lines.
For the ground insulation of high-voltage transmission and distribution network overhead lines, air is generally used. In the past, distribution lines (except for 380V below 10kV) generally used bare wires. However, due to the complex distribution environment in urban areas, short-circuit grounding and lightning strikes often occur, resulting in reduced power supply reliability. Therefore, currently, insulated wires (i.e. the outer layer of the wire is wrapped with insulation) are generally used for overhead lines below 10kV, which is called insulated overhead lines.
The installation and maintenance of bare wire lines often create significant conflicts with greening and forestry in areas with many trees. The use of overhead insulated wires can reduce tree felling (during the initial installation and operation maintenance stages), solve many problems, reduce conflicts with departments such as greening and forestry, protect the ecological environment, beautify the city, and reduce line grounding faults.
Suitable for areas with frequent flying metal dust and pollution
In the old industrial area, due to inadequate environmental protection standards, metal processing enterprises often have flying metal dust in the wind. Causing short circuits and grounding faults in overhead distribution lines in polluted areas of thermal power plants and chemical plants. The use of overhead insulated conductors is a better way to prevent short circuit grounding of 10kV distribution lines.

Suitable for salt spray areas
Salt spray causes severe corrosion to bare wires, greatly reducing their tensile strength. When exposed to wind and rain, it can lead to wire breakage, causing short-circuit grounding accidents and shortening the service life of the line. The use of overhead insulated wires can effectively prevent salt spray corrosion. Because of the insulation layer protection, it can reduce the corrosion of conductors by salt spray, delay the aging of the circuit, and extend the service life of the circuit.
Suitable for areas with frequent lightning strikes
Due to a layer of insulation protection, overhead insulated conductors can reduce lightning strikes on the line, and even if there is lightning, the impact will be much smaller. In a minefield; The insulation of lines erected with bare wires generally decreases rapidly, and there are often grounding accidents caused by bursting. After replacing with overhead insulated wires, the power outage time for grounding faults can be reduced.
1kv/10kv/35kV strip steel insulated overhead line, 35kV all aluminum insulated overhead line - comply with standard QB/DZ2020-01-2020
JKLGYJ-10kv-1 * 95/15 Parameters Hubei Shiyan Overhead Insulated Line Manufacturer
Transportation precautions;
It is strictly prohibited to throw cables or cable reels containing cables from a height during transportation, especially at lower temperatures (usually around 5 ℃ or below). Throwing or dropping cables may cause insulation and sheath cracking. Try to avoid storing cables in an exposed manner outdoors as much as possible, and cable reels are not allowed to be laid flat. When lifting the packaging of the JKLYJ overhead line model, it is strictly prohibited to lift several reels at the same time. On vehicles, ships, and other transportation vehicles, cable reels should be secured using appropriate methods to prevent collisions or tipping over, in order to prevent mechanical damage to the cables. Cables must not come into contact with acids, alkalis, and mineral oils, and must be stored separately from these corrosive substances There shall be no harmful gases that damage insulation or corrode metals in the warehouse where cables are stored. During the storage period, the cable should be rolled regularly (once every 3 months in summer, and may be extended at discretion in other seasons). When rolling, roll the storage tray upside down to prevent the bottom from getting damp and rotting. When storing, it is important to regularly pay attention to whether the cable head is intact and undamaged.
AfterSalesService :