35KV specification full inspection of overhead insulated wire JKLGYJ35KV1 * 240/30 steel core aluminum stranded wire
35KV specification full inspection of overhead insulated wire JKLGYJ35KV1 * 240/30 steel core aluminum stranded wire

35KV specification full inspection of overhead insulated wire JKLGYJ35KV1 * 240/30 steel core aluminum stranded wire

Category:

Electrical Engineering/Wire and cable/Insulated wire

Model:

JKLGYJ-35KV-1*240/30

Brand:

Zheng Fan

model:

JKLGYJ-35KV-1*240/30

Core material:

steel wire

Product Certification:

ISO9001-2000

Sheath thickness:

nine point five zero

Processing & Customization:

yes

Scope of Application:

fictional

purpose:

Power transmission and transformation

Is it a cross-border source of goods:

yes

Retail Price

23.99USD


重量

kg

  • Product Description
  • model

    JKLGYJ-35KV-1*240/30

    Core material

    steel wire

    Product Certification

    ISO9001-2000

    Sheath thickness

    nine point five zero

    Processing & Customization

    yes

    Scope of Application

    fictional

    purpose

    Power transmission and transformation

    Is it a cross-border source of goods

    yes

    Description :

       Hebi overhead insulated line 35KV specification JKLGYJ35KV1 * 240/30 wholesale and retail

      Details of the use of overhead insulated conductors:

       Due to the additional insulation layer, overhead insulated conductors have superior insulation performance compared to bare conductors, which can reduce the distance between lines, lower the insulation requirements for supporting components, and increase the number of circuits installed on the same pole.

       The installation and maintenance of bare wire lines often create significant conflicts with greening and forestry in areas with many trees. The use of overhead insulated wires can reduce tree felling (during the initial installation and operation maintenance stages), solve many problems, reduce conflicts with departments such as greening and forestry, protect the ecological environment, beautify the city, and reduce line grounding faults.

       Suitable for areas with frequent flying metal dust and pollution

       In the old industrial area, due to inadequate environmental protection standards, metal processing enterprises often have flying metal dust in the wind. Causing short circuits and grounding faults in overhead distribution lines in polluted areas of thermal power plants and chemical plants. The use of overhead insulated conductors is a better way to prevent short circuit grounding of 10kV distribution lines.

      Analysis and Introduction of JKLGYJ-35KV-240/30:

      JKLGYJ letters represent model numbers

      35KV represents the voltage level

      240 represents the cross-sectional area of aluminum

      30 represents the cross-sectional area of steel

       35kV strip steel core overhead insulated line - Implementation standard QB/DZ2020-01-2020

       Hebi overhead insulated line 35KV specification JKLGYJ35KV1 * 240/30 wholesale and retail

      

      Packaging and standards

       The surface of finished overhead insulated conductor cables should have continuous markings indicating the manufacturer's name, product model, and rated voltage. The logo should have clear handwriting, be easily recognizable, and be scratch resistant. The finished cable markings shall comply with the provisions of GB/T6995.3.

      Test methods and inspection rules:

      The product should be inspected and qualified by the quality inspection department of the manufacturing plant before leaving the factory, and the factory products should be accompanied by a certificate of conformity. The product should be tested and accepted according to regulations. The sampling quantity of the delivery batch shall be selected according to the GB/T14049-2008 standard, or as agreed upon by both parties. If the user does not request it, it shall be carried out according to the manufacturer's regulations. If the results of the sampling project are not qualified, double the sampling for a second test. If it still fails, 100% inspection should be carried out.

    AfterSalesService :

    Key words:
    • Overhead insulated wire