U100BP/146 national standard insulator XTXWP100 glass insulator steel core aluminum stranded wire
Category:
Electrical Engineering/Protective hardware/Spacer rod
Model:
U100BP/146- XTXWP100
Brand:
Zheng Fan
model:
U100BP/146- XTXWP100
product grade:
first-class
Implement quality standards:
National Standard
Processing & Customization:
yes
Minimum arc distance:
four hundred
Structural height:
one hundred and forty-six
Scope of Application:
transmission line
purpose:
High voltage and ultra-high voltage
Place of Origin:
Hebei
Retail Price
25.99USD
重量
kg
- Product Description
-
model U100BP/146- XTXWP100
product grade first-class
Implement quality standards National Standard
Processing & Customization yes
Minimum arc distance four hundred
Structural height one hundred and forty-six
Scope of Application transmission line
purpose High voltage and ultra-high voltage
Place of Origin Hebei
Description :
U100BP/146 national standard insulator XTXWP100 glass insulator steel core aluminum stranded wire
Characteristics of tempered glass insulators:
Tempered glass bead (English name: Tempered glass bead), tempered glass insulator products are used for high voltage and ultra-high voltage ACDC transmission lineUsed for insulation and suspension wires. In the early years, tempered glass insulators were mostly used for utility poles, but gradually developed into many disc-shaped insulators hung at one end of high voltage power line connection towers to increase the creepage distance. They are usually made of glass or ceramic and are called insulators.
Tempered glass insulators have the characteristic of zero value self rupture. As long as it is observed on the ground or in a helicopter, there is no need to climb the pole and inspect each piece, which reduces the labor intensity of workers.
The products introduced into the production line have an annual self breakage rate of 0.02-0.04%, which can save maintenance costs on the circuit. Good resistance to arc and vibrationThe new surface of the glass insulator that suffered lightning burns during operation is still a smooth glass body with a tempered internal stress protection layer, so it still maintains sufficient insulation and mechanical strength.There have been multiple incidents of conductor icing induced vibration on 500kV transmission lines. After testing, the mechanical and electrical performance of the glass insulators affected by conductor vibration did not deteriorate.Good self-cleaning performance and resistance to aging According to the general feedback from the power department, glass insulators are not easy to accumulate dirt and are easy to clean. The glass insulators used in the southern transmission lines are washed clean after rain.
There have been multiple incidents of conductor icing causing vibration on the 50Okv transmission line. After testing, the mechanical and electrical performance of the glass insulator affected by conductor vibration did not deteriorate. Good self-cleaning performance and resistance to aging. According to the general feedback from the power department, glass insulators are not easy to accumulate dirt and are easy to clean. The glass insulators used in the southern transmission lines are washed clean after rain. Regular sampling and testing of the mechanical and electrical performance of glass insulators on typical regional power lines have been conducted. Accumulating thousands of data points, it has been shown that the mechanical and electrical performance of glass insulators after 35 years of operation is consistent with their factory base, and there is no aging phenomenon. Large main capacity, uniform voltage distribution in series The dielectric constant of glass is 7-8, and the extended glass has a large main capacitance and uniform voltage distribution in series, which is conducive to reducing the voltage borne by insulators near the wire side and ground side, thereby reducing radio interference, reducing corona losses, and extending the life of glass insulators. This has been proven in practical operation.



Glass insulators have the following characteristics:
(1) High mechanical strength, 1% higher than that of ceramic insulators? Twice.
(2) Stable performance, not prone to aging, and higher electrical performance than ceramic insulators.
(3) The production process is few, the production cycle is short, it is convenient for mechanization and automation production, and the production efficiency is high.
(4) Due to the transparency of glass insulators, small cracks and various internal defects or damages are prone to occur during external inspections.
(5) If the glass body of the insulator has various defects, the glass body will automatically break, which is called "self breakage". After the insulator breaks, the residual hammer of the iron cap still maintains a certain mechanical strength and hangs on the line, and the line can still continue to operate.
(6) When the line patrol personnel inspect the line, it is common to see self broken insulators and replace them with new ones in a timely manner.
(7) Due to the "self rupture" characteristic of glass insulators, there is no need to conduct preventive tests on the insulators.
U100BP/146 national standard insulator XTXWP100 glass insulator steel core aluminum stranded wire
Transportation and precautions:
(1) Composite insulators should have good moisture-proof, anti vibration, anti rust, anti-theft and other protective measures to ensure the safe delivery of composite insulators to the site without damage due to the above reasons.
(2) Composite insulators with voltage levels of 330kV and above should be packaged in appropriately sized, rainproof, and rodent proof cylinders, and the end caps at both ends should be firm and reliable.
(3) The packaging of composite insulators should have sufficient strength to withstand handling during transportation, on-site storage, and installation.
(4) Suitable buffering measures should be installed inside the packaging tube to prevent damage or deformation during transportation and handling. All these materials should have chemical stability and waterproofness, and should not adhere to composite insulators or corrode them during outdoor storage.
(5) To ensure the safe arrival of goods at their destination, all packaging boxes should have correct, clear, and secure markings.
AfterSalesService :
Key words:- XTXWP100 glass insulator