Integrated assembly of above ground box pump, integrated box pump, integrated non floating pump station manufacturer
Integrated assembly of above ground box pump, integrated box pump, integrated non floating pump station manufacturer

Integrated assembly of above ground box pump, integrated box pump, integrated non floating pump station manufacturer

Category:

Security/Firefighting equipment/Fire water supply equipment

Model:

JZFBZ-750-150-60/1

Brand:

Yancheng Jinze

brand:

Yancheng Jinze

model:

JZFBZ-750-150-60/1

type:

Fire water supply

material:

stainless steel

Specifications:

7.5*1.5*0.6m

Processing & Customization:

yes

Is it imported:

No

Retail Price

28,000.00USD


重量

kg

  • Product Description
  • brand

    Yancheng Jinze

    model

    JZFBZ-750-150-60/1

    type

    Fire water supply

    material

    stainless steel

    Specifications

    7.5*1.5*0.6m

    Processing & Customization

    yes

    Is it imported

    No

    Description :

    on the groundIntegrated Box Pump SystemPump station composition: mainly composed of fire water tank, fire pump room, fire automatic constant pressure system, fire pressure boosting and stabilizing system, gas top pressure equipment, and sewage system combination; Structural form: All adopt steel structural form; Installation form: a combination of bolt assembly and welding is used; Location: Underground; Material of water tank and pump room: hot-dip galvanized or stainless steel or composite steel plate or composite metal material; Internal structure and material of the pool: full scaffold structure or portal steel frame structure; Hot dip galvanized steel pipe or composite plastic profile material; Internal structure and material of pump room: portal steel frame structure; The material is hot-dip galvanized I-beam or composite reinforced I-beam;

      Integrated selection of prefabricated box pumps: The model of the fire water pump is determined based on the design flow rate and required fire water supply pressure of the fire water supply system in the engineering project. The water pump should be one in use and one as backup, and the pressure at zero flow should not exceed 140% of the system design pressure; When the system flow rate is 150% of the rated flow rate of the water pump, the pressure should not be lower than 65% of the rated pressure.

      The fire water tank calculates the required fire extinguishing water consumption for each individual fire water supply system based on the fire design flow rate and fire duration of each individual fire water supply system in the engineering project. When a construction project consists of multiple fire water supply systems, the total amount of water used for extinguishing a single fire is the sum of the water used for extinguishing each individual system. From this, the effective volume of the fire water tank is determined, and the size of the fire water tank can be determined based on the tank volume and the actual situation on site.

      The width of the main passage in the pump room should not be less than 1.2m, and the width of the passage in front of the electrical control cabinet should not be less than 1.5m. A 2m × 2m maintenance port should be set at the top of the pump room, which should be at least 200mm above the ground. A sliding rail type top cover should be added to the top of the maintenance port for easy opening and closing; Install escalators in the pump room for easy access; Ventilation pipes should be installed at the top of the pump room, with a height of at least above the ground

    AfterSalesService :

    Key words:
    • Integrated ground tank pump