Underground fire pump station, integrated buried box pump, assembled box pump, integrated non floating pump station
Underground fire pump station, integrated buried box pump, assembled box pump, integrated non floating pump station

Underground fire pump station, integrated buried box pump, assembled box pump, integrated non floating pump station

Category:

Environmental Protection/Sewage treatment equipment/Buried sewage treatment equipment

Model:

JZFBZ-720-180-60-1

Brand:

Yancheng Jinze Water Supply Equipment Co., Ltd

model:

JZFBZ-720-180-60-1

purpose:

Fire water supply

Processing & Customization:

yes

Wastewater treatment capacity:

two hundred

category:

Underground fire pump station

Decontamination rate:

ninety-nine

pump power:

twenty

Overall dimensions:

720x180x60

Flow meter specifications:

two hundred

Diameter of water outlet pipe:

five hundred

Inlet pipe diameter:

seven hundred and fifty

Specifications:

7.2X1.8X0.6m

Is it a cross-border source of goods:

yes

manufacturer:

Yancheng Jinze

Retail Price

32,600.00USD


重量

kg

  • Product Description
  • model

    JZFBZ-720-180-60-1

    purpose

    Fire water supply

    Processing & Customization

    yes

    Wastewater treatment capacity

    two hundred

    category

    Underground fire pump station

    Decontamination rate

    ninety-nine

    pump power

    twenty

    Overall dimensions

    720x180x60

    Flow meter specifications

    two hundred

    Diameter of water outlet pipe

    five hundred

    Inlet pipe diameter

    seven hundred and fifty

    Specifications

    7.2X1.8X0.6m

    Is it a cross-border source of goods

    yes

    manufacturer

    Yancheng Jinze

    Description :

    Underground fire pump stationSelection of prefabricated box pump integrated non floating pump station: 1. The model of the fire pump unit is determined based on the design flow rate and required fire water supply pressure of the fire water supply system in the engineering project. The water pump should be one in use and one as backup, and the pressure at zero flow should not exceed 140% of the system design pressure; When the system flow rate is 150% of the rated flow rate of the water pump, the pressure should not be lower than 65% of the rated pressure.

      The fire water tank calculates the required fire extinguishing water consumption for each individual fire water supply system based on the fire design flow rate and fire duration of each individual fire water supply system in the engineering project. When a construction project consists of multiple fire water supply systems, the total amount of water used for extinguishing a single fire is the sum of the water used for extinguishing each individual system. From this, the effective volume of the fire water tank is determined, and the size of the fire water tank can be determined based on the tank volume and the actual situation on site.

      The width of the main passage in the pump room should not be less than 1.2m, and the width of the passage in front of the electrical control cabinet should not be less than 1.5m. A 2m × 2m maintenance port should be set at the top of the pump room, which should be at least 200mm above the ground. A sliding rail type top cover should be added to the top of the maintenance port for easy opening and closing; Install escalators in the pump room for easy access; Ventilation pipes should be installed at the top of the pump room, with a height of at least 1.5m above the ground.

    Underground fire pump stationFeatures of the integrated non floating pump station with prefabricated box pump: 1. The buried fire water tank is assembled and welded from 1 * 1 single square punched stainless steel plate, which echoes modern architecture and has a sense of the times.

      2. The buried fire water tank is enclosed and the imported stainless steel plate has a smooth surface, so it does not require too much cleaning in daily life and is not easy to attach algae or wash away sediment in the water.

      3. The buried fire composite water tank is assembled manually, so the type and shape of the water tank can be assembled into the required I-shaped, L-shaped, Z-shaped, etc. according to the shape of the house.

      4. The integrated buried fire box pump is widely used as a liquid storage container in hotels, residential areas, commercial housing, production-oriented enterprises for water and beverage storage, as well as in the pharmaceutical, environmental protection, and chemical industries.

      5. Food grade stainless steel SUS304 greatly extends the service life of the radiator and can effectively prevent secondary pollution of water quality.

      6. The integrated structure of the buried fire box pump is unique and reasonable, and the flexible and reasonable plate design can adapt to containers of various size combinations.

      7. The high-strength stamping plate and evenly distributed stainless steel tension bars inside the box ensure that the pressure on the box is uniform and reasonable. The advantages of outdoor buried integrated fire pump station are reflected,

    AfterSalesService :

    Key words:
    • Underground fire pump station