Underground fire pump station, integrated buried box pump, buried fire water tank, and non floating pump station function
Underground fire pump station, integrated buried box pump, buried fire water tank, and non floating pump station function

Underground fire pump station, integrated buried box pump, buried fire water tank, and non floating pump station function

Category:

Environmental Protection/Sewage treatment equipment/Buried sewage treatment equipment

Model:

JZFBZ-700-150-50-1

Brand:

Yancheng Jinze Water Supply Equipment Co., Ltd

model:

JZFBZ-700-150-50-1

purpose:

Fire water supply

Processing & Customization:

yes

Wastewater treatment capacity:

one hundred and eighty

category:

Underground fire pump station

Decontamination rate:

ninety-nine

pump power:

eighteen

Overall dimensions:

700x150x50

Flow meter specifications:

one hundred and fifty

Diameter of water outlet pipe:

four hundred

Inlet pipe diameter:

seven hundred and fifty

Specifications:

7X1.5X0.5m

Is it a cross-border source of goods:

No

manufacturer:

Yancheng Jinze

Retail Price

30,000.00USD


重量

kg

  • Product Description
  • model

    JZFBZ-700-150-50-1

    purpose

    Fire water supply

    Processing & Customization

    yes

    Wastewater treatment capacity

    one hundred and eighty

    category

    Underground fire pump station

    Decontamination rate

    ninety-nine

    pump power

    eighteen

    Overall dimensions

    700x150x50

    Flow meter specifications

    one hundred and fifty

    Diameter of water outlet pipe

    four hundred

    Inlet pipe diameter

    seven hundred and fifty

    Specifications

    7X1.5X0.5m

    Is it a cross-border source of goods

    No

    manufacturer

    Yancheng Jinze

    Description :

    Underground fire pump stationIt is to establish a complete integrated non floating pump station system, which includes various parts such as stainless steel water tank, fire hydrant pump room, sprinkler pump room, channel steel profile, connecting bolts, pit and embedded bolts; Consider the pit as a whole consisting of a side wall foundation, a reinforced concrete slab foundation at the bottom, and a sand and gravel cushion layer placed under the reinforced concrete slab foundation; The third is to fasten the fire hydrant pump room and sprinkler pump room to the reinforced concrete slab foundation through embedded bolts embedded in the foundation, and place them in a stainless steel water tank. This structural design has several obvious features: firstly, the stainless steel water tank is composed of a top plate and side plates; The second is that the channel steel profile is connected to the bottom surface of the four wall side plates of the stainless steel water tank through connecting bolts, and a rubber sealing strip is provided between the two; A concave rectangular plane is provided on the reinforced concrete slab foundation, with a length greater than the length of the stainless steel water tank and a width greater than the width of the stainless steel water tank; Thirdly, the channel steel profile is fastened to the concave plane of the reinforced concrete slab foundation through pre embedded bolts, and a rubber sealing strip is provided between the two; The fourth is that the concave plane and concave side of the reinforced concrete slab foundation are filled with sealant between the channel steel profile, and the sealant is silicon copper sealant or silicon steel structural adhesive; The upper end of the pre embedded bolt connecting the groove steel profile and the concave plane of the reinforced concrete slab foundation is submerged in the sealant.

      By eliminating the bottom plate of the water tank and connecting the side plate of the box to the reinforced concrete foundation, we not only completely eliminate the effect of buoyancy on the box, but also ensure that the bottom plate of the box has no leakage point. At the same time, it is easy to install, has a short engineering cycle, and saves manpower and material resources.

    AfterSalesService :

    Key words:
    • Underground fire pump station