Underground fire pump station fire booster water supply equipment anti floating buried box pump integrated manufacturer
Underground fire pump station fire booster water supply equipment anti floating buried box pump integrated manufacturer

Underground fire pump station fire booster water supply equipment anti floating buried box pump integrated manufacturer

Category:

Environmental Protection/Sewage treatment equipment/Buried sewage treatment equipment

Model:

JZFBZ-800-200-60-1

Brand:

Yancheng Jinze Water Supply Equipment Co., Ltd

model:

JZFBZ-800-200-60-1

purpose:

Fire water supply

Processing & Customization:

yes

Wastewater treatment capacity:

two hundred

category:

Underground fire pump station

Decontamination rate:

ninety-nine

pump power:

twenty-two

Overall dimensions:

800x200x60

Flow meter specifications:

two hundred

Diameter of water outlet pipe:

six hundred

Inlet pipe diameter:

eight hundred

Specifications:

8x2x0.6m

Is it a cross-border source of goods:

No

manufacturer:

Yancheng Jinze

Retail Price

28,000.00USD


重量

kg

  • Product Description
  • model

    JZFBZ-800-200-60-1

    purpose

    Fire water supply

    Processing & Customization

    yes

    Wastewater treatment capacity

    two hundred

    category

    Underground fire pump station

    Decontamination rate

    ninety-nine

    pump power

    twenty-two

    Overall dimensions

    800x200x60

    Flow meter specifications

    two hundred

    Diameter of water outlet pipe

    six hundred

    Inlet pipe diameter

    eight hundred

    Specifications

    8x2x0.6m

    Is it a cross-border source of goods

    No

    manufacturer

    Yancheng Jinze

    Description :

    Underground fire pump stationThe water tanks of the integrated manufacturer of anti floating buried box pumps for fire boosting water supply equipment can be mainly divided into three different types, and the products presented by these three different materials are also different. Let me take you to understand the differences between them!

      This article briefly discusses the importance of foundation engineering and construction management status in buried integrated fire water tank projects, and proposes specific measures to do a good job in foundation construction management for reference. With the rapid development of the social economy, people's dependence on fire protection is also increasing. Therefore, integrated fire water tanks will inevitably have a huge impact on people's work and life, as well as the prosperity and stability of society. Especially for the construction of fire water tank foundations, which require strong technical expertise and large capital investment, and are prone to various problems during the construction process, it seriously affects the progress of fire engineering.

      Equipment foundation of buried fire pump station: 1. Design the foundation of buried integrated fire water tank according to drainage requirements; The operating weight and top covering soil of buried water tanks

      2. The equipment foundation is a two-layer seat foundation layer of mudstone and limestone, and the low-level bearing capacity value is designed according to fak=1000kpa

      3. Concrete strength: The concrete strength of the bottom plate is c25, all of which are waterproof concrete with an impermeability grade of p6, a waterproof grade of 2, a cantilever grade of c25, and a cushion layer of c15

      4. The thickness of the entire board foundation is 250mm, and there must be a distance of at least 800mm between the edge and the breakthrough position for seat installation space

      5. In addition to meeting the design elevation, the base elevation also needs to enter the bearing layer by 300mm; a 100mm thick C15 plain muddy soil cushion layer should be made under the bottom plate

      6. Slope protection is required around the excavation to avoid tower defense during construction

      7. The reinforcement of the foundation slab is usually double layered and bi-directional

      8. Admixtures: Construction shall refer to the "Technical Specification for Application of Concrete Admixtures" GB50119-2003. SY-K mixed expansion fiber crack resistant waterproofing agent can be used, and the parameters are mainly determined by different manufacturers' ratios.

      9. Refer to the plan drawing 16G106-3 for detailed drawings of steel reinforcement structures related to local annotations

    AfterSalesService :

    Key words:
    • Underground fire pump station