Underground fire pump station fire booster water supply equipment anti floating buried box pump integrated manufacturer
Category:
Environmental Protection/Sewage treatment equipment/Buried sewage treatment equipment
Model:
JZFBZ-800-200-60-1
Brand:
Yancheng Jinze Water Supply Equipment Co., Ltd
model:
JZFBZ-800-200-60-1
purpose:
Fire water supply
Processing & Customization:
yes
Wastewater treatment capacity:
two hundred
category:
Underground fire pump station
Decontamination rate:
ninety-nine
pump power:
twenty-two
Overall dimensions:
800x200x60
Flow meter specifications:
two hundred
Diameter of water outlet pipe:
six hundred
Inlet pipe diameter:
eight hundred
Specifications:
8x2x0.6m
Is it a cross-border source of goods:
No
manufacturer:
Yancheng Jinze
Retail Price
28,000.00USD
重量
kg
- Product Description
-
model JZFBZ-800-200-60-1
purpose Fire water supply
Processing & Customization yes
Wastewater treatment capacity two hundred
category Underground fire pump station
Decontamination rate ninety-nine
pump power twenty-two
Overall dimensions 800x200x60
Flow meter specifications two hundred
Diameter of water outlet pipe six hundred
Inlet pipe diameter eight hundred
Specifications 8x2x0.6m
Is it a cross-border source of goods No
manufacturer Yancheng Jinze
Description :
Underground fire pump stationThe water tanks of the integrated manufacturer of anti floating buried box pumps for fire boosting water supply equipment can be mainly divided into three different types, and the products presented by these three different materials are also different. Let me take you to understand the differences between them!
This article briefly discusses the importance of foundation engineering and construction management status in buried integrated fire water tank projects, and proposes specific measures to do a good job in foundation construction management for reference. With the rapid development of the social economy, people's dependence on fire protection is also increasing. Therefore, integrated fire water tanks will inevitably have a huge impact on people's work and life, as well as the prosperity and stability of society. Especially for the construction of fire water tank foundations, which require strong technical expertise and large capital investment, and are prone to various problems during the construction process, it seriously affects the progress of fire engineering.

Equipment foundation of buried fire pump station: 1. Design the foundation of buried integrated fire water tank according to drainage requirements; The operating weight and top covering soil of buried water tanks
2. The equipment foundation is a two-layer seat foundation layer of mudstone and limestone, and the low-level bearing capacity value is designed according to fak=1000kpa
3. Concrete strength: The concrete strength of the bottom plate is c25, all of which are waterproof concrete with an impermeability grade of p6, a waterproof grade of 2, a cantilever grade of c25, and a cushion layer of c15
4. The thickness of the entire board foundation is 250mm, and there must be a distance of at least 800mm between the edge and the breakthrough position for seat installation space
5. In addition to meeting the design elevation, the base elevation also needs to enter the bearing layer by 300mm; a 100mm thick C15 plain muddy soil cushion layer should be made under the bottom plate
6. Slope protection is required around the excavation to avoid tower defense during construction
7. The reinforcement of the foundation slab is usually double layered and bi-directional
8. Admixtures: Construction shall refer to the "Technical Specification for Application of Concrete Admixtures" GB50119-2003. SY-K mixed expansion fiber crack resistant waterproofing agent can be used, and the parameters are mainly determined by different manufacturers' ratios.
9. Refer to the plan drawing 16G106-3 for detailed drawings of steel reinforcement structures related to local annotations


AfterSalesService :
Key words:- Underground fire pump station
More Products