KELIDA 110kV High Voltage Grounding Wire Handheld Grounding Rod/Grounding Wire 110KV High Voltage Grounding Wire Kit
Category:
Electrical Engineering/Antistatic products/static line
Model:
110KV
Brand:
Kelida Electric Appliances
Retail Price
200.00USD
重量
kg
- Product Description
-
Description :
Features of the 110 kV grounding wire kit from the Kolida brand:10kV high-voltage grounding wire is an essential safety tool for electrical workers during construction. The 110kV high-voltage grounding wire consists of an insulated operating rod, a grounding soft copper wire, and a grounding wire clamp. The insulating operating rod is processed from raw materials such as epoxy resin to meet the requirements of high voltage insulation and ensure the personal safety of electrical maintenance personnel; The grounding soft copper wire is a 25 square meter grounding wire made of multiple strands of soft copper wire twisted together and covered with a soft, heat-resistant transparent insulation layer; The grounding clip is formed by aluminum alloy die-casting.










The use and maintenance of the 110kV high-voltage grounding wire of Kelida:
1. Before using the grounding wire, it should be confirmed beforehand that the power has been cut off and that there is no voltage on the equipment before proceeding. First, connect the grounding wire clamp to the grounding grid or flat iron piece, and then use a grounding rod to tighten the wire end wires to the equipment wires. When dismantling the high-voltage grounding wire, the sequence is exactly opposite to the above.
2. The grounding wire should be properly stored. Before each use, carefully check if it is intact, if the soft copper wire is not exposed, and if the nut is not loose, otherwise it cannot be used.
3. If there is a grounding point at the suspension point, a grounding wire clamp or a dedicated copper rod should be used for grounding connection; If there is no fixed grounding point available for use; A temporary grounding point can be used, and the grounding electrode should be buried underground at a depth of not less than 0.6m.
4. The distance between the high-voltage grounding wire installed and the live equipment, taking into account the influence of the grounding wire swing, should not be less than the new value specified in the "Electricity Safety Work Regulations". 110kV grounding wire 110kV high-voltage grounding wire
5. The grounding wire inspection cycle is once every five years, and the inspection items are the same as the factory inspection. After passing the test, the grounding wire should be judged based on the magnitude of the short-circuit current and appearance inspection after being subjected to a short circuit, and generally should be scrapped.
AfterSalesService :
Key words:- 110kV high-voltage grounding wire
More Products