HTB100-203 multi impeller medium pressure blower power 1.5KW HTB transparent multi-stage medium pressure fan
Category:
Environmental Protection/Fan exhaust equipment/Medium pressure blower
Model:
HTB100-203
Brand:
Colsen
Retail Price
1,980.00USD
重量
kg
- Product Description
-
Description :
HTB100-203 multi impeller medium pressure blower power 1.5KW HTB transparent multi-stage medium pressure fan
Features:
1. The fan is mainly composed of impeller, casing, air inlet, motor, connector, cooling fan blades and other components.
2. The impeller adopts a multi blade single inlet centrifugal impeller, made of galvanized or cold-rolled steel plate, and the blades are designed based on aerodynamic principles. The WQE type impeller consists of 10 aft tilting airfoil blades, a curved front plate, and a flat rear plate. The material is made of high-strength and durable steel plates, and undergoes strict dynamic and static balance correction. It has good air performance, high efficiency, and smooth operation.
3. The air inlet adopts a convergent streamlined vortex reduction form, which reduces airflow loss and improves the efficiency of the fan.
4. The fan casing is connected to the motor through a metal casting, and the motor shaft head is equipped with a cooling fan blade. The outer wall of the metal casting has a high inlet and outlet pipe interface to cool the metal casting and shaft head, ensuring that the motor operates normally at high temperatures.
5. The motor adopts a special high-temperature motor, and the fluid part of the fan is made of heat-resistant materials, with reliable cooling structure performance. Compared to boiler induced draft fans, it has the advantages of simple structure, easy maintenance, and high cost-effectiveness.











Application of cast aluminum medium pressure blower
Food machinery equipment, sewage treatment equipment, fish pond oxygenation equipment, dust removal equipment, feeding equipment, plastic machinery equipment, packaging machinery equipment, woodworking machinery equipment, cleaning machinery equipment, printing machinery equipment, boiler combustion equipment, cooling machinery equipment, breeding enterprise equipment, exhaust gas emission equipment, laser cutting equipment, hot spring swimming pool equipment, environmental machinery equipment, vacuum dehydration equipment, blown film machinery equipment, filling machinery equipment, textile machinery equipment, paper cutting machinery equipment, suction and blowing equipment, drying and drying equipment, carving machinery equipment, sanitary napkin machinery equipment, diaper machinery equipment, air knife drying equipment, PCB circuit board equipment, beverage production line equipment, air knife water removal equipment, bean product equipment, hot air drying equipment, environmental protection Industry, etc
Principle of Transparent Medium Pressure Blower:
The common medium pressure fan is a centrifugal fan, whose impeller is covered with a mechanical shell and the center of the impeller is the air inlet. When the medium pressure fan is working, the power equipment drives the impeller to rotate, drawing air in from the air inlet. During the rotation of the blades of a centrifugal fan, a dynamic force is applied to the gas, increasing its pressure and velocity. The gas is discharged from the exhaust port along the blade path under the action of centrifugal force.
Operation and maintenance of industrial medium pressure blower:
After installation, the blower should be manually rotated before starting to check for any abnormal collisions or friction, whether the rotation direction of the motor is correct, and whether the inlet and outlet valves are in a low flow state.
2. During the operation of the fan, attention should be paid to whether there are any abnormal sounds, oil leaks, abnormal vibrations, high bearing temperature, excessive motor current, loose feet, or other abnormal phenomena inside the fan and motor, and they should be eliminated in a timely manner.
3. After using the fresh air fan, the bearing grease should be replaced.
4. Maintenance: When inspecting the casing, first loosen the screws on the horizontal split surface, open the upper half of the casing and the upper covers of the bearing boxes on both sides, and remove the rotor to repair the rotor or casing. During maintenance, special attention should be paid to whether the impeller blades are broken, whether there are cracks, and whether the main shaft is bent. Before installing and dismantling the machine casing, it is necessary to be careful to avoid damaging the rotor due to the swinging of the upper half of the casing during the installation and dismantling process.
5. During the shutdown period of the fan, the inlet and outlet of the fan should be covered properly to prevent debris from falling into the fan cavity and causing accidents.
6. The fan needs to be inspected every six months to remove dust and oil stains from the fan flow channel.
AfterSalesService :
Key words:- Multi impeller medium pressure blower