LD-5S laser dust analyzer with humidity correction function
Category:
Instrumentation/Gas analyzer/Dust detector
Model:
LD-5
Brand:
Qingdao Xinye Environmental Protection
model:
LD-5
sampling flow:
0-800
Measurement range:
( 0.001~10) mg/m3
measurement time:
twelve
measurement accuracy:
2%
Product Type:
portable
Working Voltage:
twenty-four
type:
Particle measurement
flow range:
800mi
output method:
two hundred and thirty-two
Temperature control range:
-40-70
noise:
60b
Applicable Industries:
Environment, Third Disease Control, etc
size:
180*94*181
manufacturer:
Qingdao Xinye Environmental Protection
Retail Price
23,000.00USD
重量
kg
- Product Description
-
model LD-5
sampling flow 0-800
Measurement range ( 0.001~10) mg/m3
measurement time twelve
measurement accuracy 2%
Product Type portable
Working Voltage twenty-four
type Particle measurement
flow range 800mi
output method two hundred and thirty-two
Temperature control range -40-70
noise 60b
Applicable Industries Environment, Third Disease Control, etc
size 180*94*181
manufacturer Qingdao Xinye Environmental Protection
Description :
LD-5SLaser dust analyzer(Humidity correction function)

Product Introduction
The LD-5S laser dust analyzer is an online monitoring product for laser particulate matter that can effectively eliminate humidity interference. Portable, small in size and easy to carry, optional tripod for field measurement. Equipped with continuous automatic humidity correction function, it can effectively reduce humidity interference, achieve high precision, high sensitivity, wide range, and compatibility with TSP, PM10, PM5, PM2.5, PM1.0 particle cutters. The instrument is equipped with a Φ 40mm filter membrane sampling device, which can collect particulate matter samples while continuously monitoring, and has functions such as data processing, storage, timed sampling, and dust over limit alarm. This instrument is particularly suitable for continuous online monitoring of particulate matter 24/7, as well as serving as a replacement product for existing dust meters.
Measuring principle
By shining a laser beam onto a dusty airflow, the beam produces scattered light. The higher the dust concentration, the greater the intensity of the scattered light produced, thereby measuring the dust concentration. The light scattering method is used to determine the concentration of inhalable particulate matter in the air of public places, which has the advantages of speed, sensitivity, good stability, small size, light weight, no noise, easy operation, safety and reliability. On the one hand, this method has high sensitivity and requires less sample size, and can eliminate or simplify sample processing steps, thus greatly reducing sampling and analysis time; On the other hand, this method does not require sample storage, thus avoiding or reducing various possible error factors in the analysis method.
Performance Characteristics
1. Equipped with continuous automatic humidity correction function, dedicated "correction" button, one click processing, easy operation, and results output in one minute;
2. Equipped with a filter membrane sampling unit to achieve continuous monitoring of particle concentration and compatibility with filter membrane sampling;
3. Cutting particle size: PM10, PM5, PM2.5, PM1 and TSP compatible;
4. Measurement range: 0.001-100mg/m3;
5. Repetitive error ± 2%;
6. Can connect wireless transmission devices, equipped with central station computers and dedicated software to achieve long-term continuous online monitoring of particulate matter;
7. Optional tripod for easy field measurement.
Technical Specifications
Measurement range
0.001-10 mg/m3 or 0.01-100mg/m3
detection sensitivity
0.001 mg/m3 or 0.01mg/m3
measurement time
Configure 40mm filter membrane online sampler
Particle cutter
PM10, PM5, PM2.5, PM1.0, and TSP are available for selection
repeatability error
±2%
measurement accuracy
±10%
display screen
Large screen LCD display, Chinese operation interface
measurement time
The standard time is 1 minute, with 0.1 minutes and manual mode (sampling time can be set arbitrarily)
storage
Can cyclically store 99 sets of data
Timed sampling
Can set measurement time (1~9999) seconds, shutdown time (0~9999) seconds, preheating time (0~10) seconds, and sampling frequency (1~9999) times
output interface
PC communication interface (RS232);
Printer output interface;
Analog output interface: 0-1V;
Digital output interface: level signal
power supply
Ni MH or lithium rechargeable battery pack (1.2V x 4), capable of continuous use for 8 hours; Attached is a 220VAC/12VDC power adapter
size
195mm*85mm*132mm
weight
2.4Kg
Standard Configuration
Instrument, battery, power adapter, leather bag, small screwdriver, cutter (choose one from five), filter membrane, filter membrane collection bag, instruction manual, certificate of conformity, warranty form
optional
Instrument specific communication software, micro printer, tripod, smoke sampling rod, other cutters
AfterSalesService :
Key words:- LD-5S laser dust analyzer