AMC16Z-FD Multi loop Single phase Current Measurement Device Multi loop Monitoring Device

AMC16Z-FD Multi loop Single phase Current Measurement Device Multi loop Monitoring Device

Category:

Instrumentation/Standard measuring instruments/Optical metrology standards

Model:

Brand:

Retail Price

420.00USD


重量

kg

  • Product Description
  • Description :

      1 Overview

      With the rapid development of data centers, the energy consumption problem of data centers has become increasingly prominent. Energy management and power supply and distribution design related to data centers have become hot issues. An efficient and reliable data center power distribution system solution is an effective way to improve the energy efficiency of data centers and reduce equipment energy consumption. To achieve energy conservation in data centers, it is first necessary to monitor each electrical load. However, data centers have a large number of load circuits, and traditional measuring instruments cannot meet the requirements of cost, volume, installation, construction, and other aspects. Therefore, multi circuit monitoring devices suitable for centralized monitoring requirements in data centers need to be adopted.

      The AMC16Z series DC precision distribution monitoring device from Ankerui Company is a measuring device specifically designed for power management of data center servers. The device is designed to be compact and capable of real-time monitoring of the full electrical parameters, input/output switches, and lightning protection status of the A+B two incoming lines and 96 outgoing lines. The alarm thresholds of all measurement channels can be set separately, and the out of limit event will immediately trigger the system's sound and light alarm. It achieves high integration of the monitoring circuit in the volume of traditional instruments.

      2 Product Models

      3 Technical parameters

      DC incoming line

      DC output line

      Note: The secondary input voltage of the DC input and output modules is 5V, and the default value of the primary current is 50A. If the Hall sensors are different, customers can set the transformation ratio through the touch screen according to their actual usage.

      Note: The secondary input voltage of the AMC16Z-FDK module is 5V, and the default value of the primary current is 50A. If the Hall sensor is different, customers can choose to

      According to actual usage, the variable ratio can be set through the touch screen.

      Active switch module

      Passive switch module

      Extended power module

      4. External structure

      5 wiring terminals

      5.1 AMC16Z-ZD

      5.2 AMC16Z-FD

      5.3 AMC16Z-FDK24

      5.4 AMC16Z-FDK48

      5.5 AMC16Z-KA

      5.6 AMC16Z-KD

      5.7 AMC16Z-DC48V

      5.8 AMC16Z-DC240V/336V

      6 Communication Protocol This protocol specifies the physical connection and communication protocol for data exchange between the AMC16Z series AC precision distribution monitoring device and data terminal equipment, and its protocol is similar to the Modbus RTU communication protocol