Intelligent power operation and maintenance AM5-F microcomputer protection and measurement device line protection device

Intelligent power operation and maintenance AM5-F microcomputer protection and measurement device line protection device

Category:

Instrumentation/Standard measuring instruments/Optical metrology standards

Model:

Brand:

Retail Price

5,250.00USD


重量

kg

  • Product Description
  • Description :

      1. Overview

      The AM series microcomputer protection and measurement device (hereinafter referred to as the device) integrates protection, measurement, and control, and is suitable for user terminal substations with voltage levels of 35kV and below. It can achieve protection and measurement of user substations. The application areas cover industries such as power, water conservancy, transportation, petroleum, chemical, coal, metallurgy, etc.

      The device adopts advanced, mature and reliable protection principles and algorithms, with strong anti-interference performance, high reliability, flexible protection implementation methods, and redundant communication design. The device has an independent high-precision current measurement circuit, multiple switch quantity acquisition and relay output, which can be used in conjunction with the comprehensive automation system of the substation or the electrical automation system of the power plant, and can achieve unmanned end-user substation distribution automation system. The device can be installed in a centralized manner by grouping screens, or directly installed on the switchgear for decentralized control.

      2Product Specifications

      AM5Model and Function Configuration Table of Series Microcomputer Protection Devices:

      8-channel AC current channel

      4-channel AC voltage channel

      16 channel switch input channel

      10 channel switch output

      8 configurable LED attributes

      1 RS485 communication interface

      

      model

      

      Main functions

      

      name

      

      Application scenarios

      

      AM5-F

      

      Three stage overcurrent protection, two-stage Io1 overcurrent protection, two-stage Io2 overcurrent protection, inverse time overcurrent protection, overload alarm (trip), control fault alarm, PT disconnection alarm, three-phase primary reclosing, low-frequency load shedding, rear acceleration overcurrent, FC lockout

      

      Line protection device

      

      Incoming/feeder line

      

      AM5-T

      

      Three stage overcurrent protection, two-stage Io1 overcurrent protection, two-stage Io2 overcurrent protection, zero sequence inverse time overcurrent protection, overload alarm (trip), control fault alarm, PT disconnection alarm, non electricity protection, FC lockout

      

      Factory transformer protection device

      

      plant-use transformer

      

      AM5-U

      

      Low voltage warning, PT disconnection alarm, overvoltage alarm, zero sequence overvoltage alarm

      

      PT monitoring device

      

      PT monitoring

      

      AM5-B

      

      Two stage overcurrent protection, inverse time overcurrent protection, control fault alarm, PT disconnection alarm, rear acceleration overcurrent protection, incoming line backup/bus tie backup

      

      Busbar protection and backup automatic switching device

      

      Mother union protection and automatic backup

      

      AM5-M

      

      Two stage overcurrent protection, two-stage Io1 overcurrent protection, inverse time overcurrent protection, overload alarm (trip), control fault alarm, low voltage protection, PT disconnection alarm, locked rotor protection, zero sequence overvoltage alarm, non electricity protection, long start-up time protection, thermal overload protection, negative sequence overcurrent (two-stage/inverse time), FC lockout

      

      Motor protection device

      

      Electric motor<2000kW

      

      AM5-C

      

      Two stage overcurrent protection, two-stage Io1 overcurrent protection, inverse time overcurrent protection, overload alarm (trip), control fault alarm, PT disconnection alarm, overvoltage trip, unbalanced voltage protection, unbalanced current protection, zero sequence overvoltage protection, non electricity protection

      

      Capacitor protection device

      

      capacitor

      

      Attachment

      

      Optional second communication interface

      

      Anti bounce module

      

      IRIG-B timing

      

      AM5-BLModel and Function Configuration Table of Series Microcomputer Protection Devices:

      model

      

      Main functions

      

      name

      

      Application scenarios

      

      AM5-BL

      

      Parallel/Split Control of PT Secondary Signals on Different Bus Lines

      

      PT parallel device

      

      PT parallel

      

      3. Appearance, hole size and installation methodAM5 series microcomputer protection and measurement device (unit: mm)

      Installation method of AM series microcomputer protection and measurement device

      4terminal block

      AM5 series microcomputer protection and measurement device

      AM5-F/T/M/B/C/U microcomputer protection device

    AfterSalesService :

    Key words:
    • 智能电力运维