Explosion equipment box for coal mines, made of anti-static and flame-retardant materials, specifically designed for the storage and transportation of underground pyrotechnic devices

Explosion equipment box for coal mines, made of anti-static and flame-retardant materials, specifically designed for the storage and transportation of underground pyrotechnic devices

Category:

Security/Explosion proof equipment/Explosion proof equipment

Model:

KL-BLG200

Brand:

Kailong Mine

Material:

Cold rolled steel plate/stainless steel

Surface Treatment:

Anti static spraying

Lock type:

Double lock/mechanical password lock

Lining material:

Conductive rubber/anti-static rubber sheet

Applicable Environment:

Coal mine underground/ground blasting station

Protection rating:

IP54 and above

Certification Mark:

MA Coal Safety Certification

color:

White/Yellow

Retail Price

10,000,000.00USD


重量

kg

  • Product Description
  • Material

    Cold rolled steel plate/stainless steel

    Surface Treatment

    Anti static spraying

    Lock type

    Double lock/mechanical password lock

    Lining material

    Conductive rubber/anti-static rubber sheet

    Applicable Environment

    Coal mine underground/ground blasting station

    Protection rating

    IP54 and above

    Certification Mark

    MA Coal Safety Certification

    color

    White/Yellow

    Description :

      The coal mine blasting box is a special safety container designed specifically for underground and surface blasting operations in coal mines. It is mainly used for temporary storage and short distance transportation of explosive materials such as civil explosives. The core solution of this device is the safety protection of high-risk explosive materials under complex working conditions. Through physical isolation and electrostatic discharge mechanisms, it prevents accidents caused by friction, impact, or electrostatic sparks. Typical working conditions include underground excavation face, coal mining face, and intermediate links in the ground blasting equipment warehouse. As a key supporting equipment for mine safety production, the coal mine blasting box must strictly comply with the national mining product safety certification requirements, ensuring extremely high intrinsic safety performance in flammable and explosive environments such as gas and coal dust. It is the infrastructure that guarantees the safety of miners' lives and the normal production order of the mine.

      The manufacturing of coal mine blasting boxes usually uses high-strength cold-rolled steel plates or stainless steel plates, and the box structure is reinforced with ribs to have excellent impact and compression resistance. The inner wall is lined with conductive rubber or anti-static coating, and the surface resistivity is usually controlled between 10 ^ 6-10 ^ 9 ohms to ensure effective elimination of static electricity accumulation. The box is equipped with a dual locking mechanism, usually a mechanical password lock or a dedicated explosion-proof lock, and the key is kept by a dedicated person to achieve dual lock management for two people. In terms of implementing standards, it is necessary to comply with the "Blasting Equipment Box for Coal Mines" and relevant safety technical specifications for mining products. Some high-end models have passed MA (Coal Safety) certification. The bottom of the box is equipped with anti slip pads or fixing holes for stable installation on the mining truck or bracket. The joint is treated with sealing strips, which have certain dustproof and waterproof capabilities and are suitable for the humid and dusty environment underground.


      When selecting a coal mine blasting box, the volume size should be determined based on the actual blasting operation scale, with common specifications ranging from tens of liters to hundreds of liters. If the workspace is narrow, a compact design should be chosen; If long-distance transportation is required, special attention should be paid to the seismic structure of the box and the strength of the handle. However, there are differences between the internal lining structure and anti-static requirements, and mixing is strictly prohibited. For high gas mines, flame retardant and anti-static products with clear MA markings must be selected, and ordinary metal toolboxes cannot be replaced. In addition, the weight of the box should also be considered to ensure that single or double people can easily transport it. If vehicle transportation is required, models with forklift slots or binding fixing points at the bottom should be selected to improve logistics efficiency and safety.


      The daily maintenance focus of coal mine blasting boxes is to keep the box clean and the locks flexible. After each use, residual powder or dust inside the box should be cleaned to avoid long-term adhesion of corrosive substances. Regularly check the integrity of the anti-static coating, and if any damage is found, it should be repaired in a timely manner to prevent electrostatic failure. Locks need to be regularly lubricated to ensure smooth opening and avoid being unable to open in emergency situations due to rust. When stored, it should be placed in a dry and ventilated place, avoiding direct sunlight and rain to prevent the box from rusting. During use, rough handling is strictly prohibited to avoid severe collisions that may cause deformation of the box and affect its sealing and protective performance. Establish a regular inspection ledger to record the condition and maintenance of each coal mine blasting box, ensuring that it is always in good working condition and providing reliable safety guarantees for mining blasting operations.

    AfterSalesService :

    Key words: