Tai'an Yucheng KCS-120D Mining Dust Removal Fan Explosion proof Dust Removal Fan
Category:
mechanical equipment/Fans, exhaust equipment/Dust removal fan
Model:
KCS-120D
Brand:
Tai'an Yucheng
Retail Price
10,000.00USD
重量
kg
- Product Description
-
Description :
Tai'an Yucheng KCS-120D Mining Dust Removal Fan Explosion proof Dust Removal Fan
KCS-120DDust removal fan, explosion-proof dust removal fan, mining dust removal fan, tunneling machine dust removal fan
Tai'an Yucheng Mining Equipment Co., Ltd. produces mining dust removal fans, including the KCS-120D wet dust removal fan, KCS-150DMining wet dust removal fan, KCS-230D coal mine wet dust removal fan, KCS-410D mining dust removal fan, KCS-180 dust removal fan, KCS-408 coal mine dust removal fan, etc., with complete specifications and models. Now let's introduce KCS-120D mining dust removal fan.
1、 KCS-120D mining dust removal fan model representation:

2、 KCS-120D Mining Dust Removal Fan Introduction:
The KCS-120D mining dust removal fan consists of an explosion-proof extraction type local ventilation fan (hereinafter referred to as the fan) used in coal mines and a wet vibrating wire dust collector (also known as a wet fiber grid dust collector) (hereinafter referred to as the dust collector). The equipped fan can choose axial flow, centrifugal, mixed flow series explosion-proof extraction type local ventilation fan.
3、 Working conditions of KCS-120D mining dust removal fan:
1. Applicable ambient temperature: 0-40 ℃;
2. The altitude shall not exceed 1000 meters;
3. Relative humidity ≤ 95% (25 ℃);
4. Used for underground coal mines containing methane and coal dust explosive gases;
5. Atmospheric pressure: (86-106) kPa;
6. Applicable spray water supply pressure: ≥ 0.3MPa;
7. Applicable dust concentration range: (0-24000) mg/cm3
4、 Performance parameters of KCS-120D mining dust removal fan:
Total dust removal efficiency: ≥ 97%;
Respiratory dust removal efficiency: (90-98)% (positively correlated with filtration wind speed);
Liquid to gas ratio: (0.02-0.09) L/m3 (processing air volume) (depending on the concentration of dust in the air);
The static pressure efficiency of the ventilation fan part of the dust removal fan shall not be less than 55%;
Working resistance: 1200Pa (deviation from rated working resistance should not exceed 10%);
Applicable spray water supply pressure: ≥ 0.3MPa;
Applicable ambient temperature: 0-40 ℃;
Working mode: Long term continuous work;
Work noise: ≤ 85dB (A);
The KCS-120D mining dust removal fan is installed horizontally and has a foot bracket and suspension hole. In the use of coal mine excavation working face, it can be installed on one side of the roadway or suspended for use, and moved together with the excavation machine. The installation and use of this product must comply with the relevant provisions of the "Coal Mine Safety Regulations". KCS-120D mining dust removal fan Taian Yu is here to provide for you.



AfterSalesService :